Análisis de los factores ambientales y ocupacionales en la concentración de aerobacterias en unidades de cuidado intensivo del Hospital Universitario Fernando Troconis, 2009 Santa Marta- Colombia / Analysis of occupational and environmental factors in the concentration of aerobacters in intensive care units of the Fernando Troconis Universitary Hospital, 2009 Santa Marta-Colombia
Vélez-Pereira, Andrés M; Camargo Caicedo, Yiniva.
Afiliação
  • Vélez-Pereira, Andrés M; Grupo de Investigación en Modelación de Sistemas Ambientales. Santa Marta. CO
  • Camargo Caicedo, Yiniva; Grupo de Investigación en Modelación de Sistemas Ambientales. Santa Marta. CO
rev. cuid. (Bucaramanga. 2010) ; 5(1): 595-605, ene.-dic. 2014. ilus, tab
Artigo em Espanhol | LILACS, BDENF - Enfermagem | ID: lil-752174
Biblioteca responsável: CO646.9
RESUMEN

Introducción:

La evaluación de la calidad biológica del aire de ambientes hospitalarios resulta de especial interés debido a que los pacientes puedan servir como una fuente de bacterias patógenas para el personal del hospital, los visitantes y otros pacientes, siendo relevante en unidades de asistencia especializadas en atención de patologías crónicas como cáncer, SIDA y pacientes con trasplante de órganos o con complicaciones severas en su estado de salud, y que requieren una intervención masiva para su tratamiento en salas de cirugía y/o unidades de cuidado intensivo. Evaluar la influencia de factores ambientales y de ocupación de la unidad en la concentración de aerobacterias de unidades de cuidado intensivo del Hospital Universitario Fernando Troconis. Materiales y

Métodos:

Se colectaron muestras triplicadas con agar selectivo para Staphylococcus spp. y Pseudomonas spp., en dos estaciones de cada una de las tres UCI, mediante impactador de 2 etapas ubicado a altura de1.5m y caudal constante (28.3l/min) durante 5min, incubándolas a 37°C por 48h. Los factores ambientales se registraron con anemómetro Kestrel 4500 y ocupación de la unidad mediante registro manual del número de pacientes y personal asistencial de la unidad.

Resultados:

La máxima concentración fue 979.9±31.3UFC/m3 y el máximo promedio, 315.6±59.7UFC/m3. Staphylococcus spp. Superaron la concentración de Pseudomonas spp. La máxima ocupación fue en UCI Adulto, mayor temperatura en UCI Pediátrica y humedad más baja en UCI Adulto. Discusión y

Conclusiones:

La concentración de aerobacterias superó valores reportados por estudios aerobiológicos hospitalarios, y presenta relaciones leves con temperatura y escasa o nula con ocupación de la unidad.
ABSTRACT

Introduction:

Assessing of biological quality of air in hospital environments is of particular interest because patients can be a source of pathogenic bacteria for hospital staff, visitors and other patients. It is relevant in specialized care of chronic diseases like cancer, AIDS and organ transplant patients or severe health complications, which require massive intervention for treatment in the operating room and/or intensive care units. To evaluate the influence of environmental factors and intensive care unit occupancy in the concentration of aerobacteria in intensive care units of Fernando Troconis Universitary Hospital. Materials and

Methods:

Triplicate samples were collected with selective agar for Staphylococcus spp. and Pseudomonas spp. using two-stage cascade impactor located 1.5 m high and constant flow (28.3l/min) for five minutes, locating two stations in each of the three ICU; the collected samples were incubated at 37°C for 48 hours. Environmental factors were recorded with anemometer Kestrel 4500 and occupancy of the unit by manually recording the number of patients and health care personnel of the unit.

Results:

Maximum concentration was 979.9±31.3CFU/m3 and maximum average 315.6±59.7CFU/m3. Staphylococcus spp. exceeded the concentration of Pseudomonas spp. Maximum intensive care unit occupancy was in adult ICU, higher temperature in pediatric ICU and lower humidity in adult ICU. Discussion and

Conclusions:

Aerobacteria concentration exceeded values reported by other aerobiological studies in hospital also has little relationship with temperature and little or no with intensive care unit occupancy.
Assuntos


Texto completo: Disponível Coleções: Bases de dados internacionais Base de dados: BDENF - Enfermagem / LILACS Assunto principal: Ocupação de Leitos / Infecção Hospitalar / Cuidados Críticos / Meio Ambiente / Viabilidade Microbiana / Material Particulado Tipo de estudo: Guia de prática clínica Aspecto: Preferência do paciente Limite: Humanos País/Região como assunto: América do Sul / Colômbia Idioma: Espanhol Revista: Rev. cuid. (Bucaramanga. 2010) Ano de publicação: 2014 Tipo de documento: Artigo País de afiliação: Colômbia Instituição/País de afiliação: Grupo de Investigación en Modelación de Sistemas Ambientales/CO

Texto completo: Disponível Coleções: Bases de dados internacionais Base de dados: BDENF - Enfermagem / LILACS Assunto principal: Ocupação de Leitos / Infecção Hospitalar / Cuidados Críticos / Meio Ambiente / Viabilidade Microbiana / Material Particulado Tipo de estudo: Guia de prática clínica Aspecto: Preferência do paciente Limite: Humanos País/Região como assunto: América do Sul / Colômbia Idioma: Espanhol Revista: Rev. cuid. (Bucaramanga. 2010) Ano de publicação: 2014 Tipo de documento: Artigo País de afiliação: Colômbia Instituição/País de afiliação: Grupo de Investigación en Modelación de Sistemas Ambientales/CO
...