Variabilidade na sensibilidade à heparina de reagentes do TTPA em plasmas heparinizado in vitro e de pacientes heparinizados / Variability in heparin sensitivity of TTPA reagents in heparinized plasma in vitro and patients receiving heparin
Serralvo, Fernanda Daniela; Zamboti, Jacinta Ludovico; Favero, Maria Emilia; Bregano, José Wander.
Afiliação
  • Serralvo, Fernanda Daniela; s.af
  • Zamboti, Jacinta Ludovico; Universidade Estadual de Londrina. Centro de Ciências Exatas. Departamento de Estatística. BR
  • Favero, Maria Emilia; Universidade Estadual de Londrina. Centro de Ciências da Saúde. Departamento de Análises Clínicas e Toxicológicas. Londrina. BR
  • Bregano, José Wander; Universidade Estadual de Londrina. Centro de Ciências da Saúde. Departamento de Patologia Análises Clínicas e Toxicológicas. Londrina. BR
Semina cienc. biol. saude ; 36(1,supl): 243-250, ago. 2015. tab, ilus
Artigo em Português | LILACS | ID: lil-770859
Biblioteca responsável: BR512.1
RESUMO

Introdução:

No final da década de 80 e início dos anos 90 vários estudos demonstraram a falta de padronização e a variabilidade nos resultados do TTPA devido a diferentes sensibilidades à heparina dos reagentes empregados para sua determinação.

Objetivo:

Avaliar a sensibilidade à heparina de reagentes utilizados para a determinação do TTPA em amostras de plasmas heparinizadas in vitro e de pacientes em uso de heparina não fracionada (HNF). Material e

Métodos:

Para este estudo foi utilizado um pool de plasma heparinizado, com concentrações de 0,1 até 1,0 unidade de heparina/mL, 29 pacientes em uso de HNF e 8 kits de reagentes para a determinação do TTPA. Resultados e Discussão Com os plasmas heparinizados in vitro os resultados com o reagente da Actin® foram estatísticamente diferente dos da Labtest®, da Human® e da Clot®. O melhor coeficiente de correlação, resultado do TTPA versus concentração de HNF, foi observado com o reagente da Stago® (R=0,9919). Quando-se empregou os plasmas de pacientes em uso de HNF os resultados do Actin® e do Actin FSL® foram estatisticamente diferentes dos da Clot®.

Conclusão:

Diferenças estatisticamente significativas, nos valores de TTPA, ainda são observadas, tanto em plasmas de pacientes em uso de HNF como em plasmas heparinizados in vitro de acordo com o reagente utilizado.
ABSTRACT

Introduction:

At the end of the 1980s and at the beginning of the 1990s, several studies showed lack of standardization and variability in APPT results due to the different sensibilities to heparin in reagents used for its determination.

Objective:

To evaluate the sensibility to heparin in the different reagents used to determine APPT in samples of heparinized plasma in vitro and in patients using non-fractioned heparin (NFH). Material and

Methods:

This study was performed with a pool of heparinized plasma with concentrations from 0.1 to 1.0 unit heparin/mL, 29 patients using NFH and 8 reagent kits for TTPA determination. Results and

Discussion:

Using heparinized plasma in vitro, there was a statistically significant difference with Actin® reagent in relation to Labtest®, Human® and Clot® reagents. The best correlation coefficient, a result of the APTT versus UFH concentration was observed with reagent from Stago® (R = 0.9919). When we used the plasma from patients using UFH, the results of Actin ® and Actin FSL® were statistically different from the Clot®.
Assuntos


Texto completo: Disponível Coleções: Bases de dados internacionais Contexto em Saúde: ODS3 - Saúde e Bem-Estar Problema de saúde: Meta 3.9: Reduzir o número de mortes por produtos químicos perigosos e contaminação do ar e água do solo Base de dados: LILACS Assunto principal: Heparina / Monitoramento Ambiental / Anticoagulantes Tipo de estudo: Estudo diagnóstico Limite: Adulto / Feminino / Humanos / Masculino Idioma: Português Revista: Semina cienc. biol. saude Assunto da revista: Biologia / Medicina Ano de publicação: 2015 Tipo de documento: Artigo País de afiliação: Brasil Instituição/País de afiliação: Universidade Estadual de Londrina/BR

Texto completo: Disponível Coleções: Bases de dados internacionais Contexto em Saúde: ODS3 - Saúde e Bem-Estar Problema de saúde: Meta 3.9: Reduzir o número de mortes por produtos químicos perigosos e contaminação do ar e água do solo Base de dados: LILACS Assunto principal: Heparina / Monitoramento Ambiental / Anticoagulantes Tipo de estudo: Estudo diagnóstico Limite: Adulto / Feminino / Humanos / Masculino Idioma: Português Revista: Semina cienc. biol. saude Assunto da revista: Biologia / Medicina Ano de publicação: 2015 Tipo de documento: Artigo País de afiliação: Brasil Instituição/País de afiliação: Universidade Estadual de Londrina/BR
...