Your browser doesn't support javascript.
loading
Frecuencia de colonización de Staphylococcus Aureus Meticilino - Resistente, de Enterobacterias y de Candida spp. en estetoscopios y teléfonos móviles en una Unidad de Cuidados Intensivos Neonatal / Frequency of colonization of methicillin-resistant Staphylococcus Aureus, Enterobacteria and Candida Spp. in stethoscopes and cellular phones, inside a Neonatal Intensive Care Unit
Hernández, Mauricio Andrés; Barros, Camilo Ernesto; Martínez, Nicolás; Olaya, Hernando Andrés; Villegas, Sonia; Álvarez, Carlos Arturo.
Afiliação
  • Hernández, Mauricio Andrés; s.af
  • Barros, Camilo Ernesto; s.af
  • Martínez, Nicolás; s.af
  • Olaya, Hernando Andrés; s.af
  • Villegas, Sonia; s.af
  • Álvarez, Carlos Arturo; s.af
Rev. salud bosque ; 1(1): 17-24, 2011. tab, graf
Artigo em Espanhol | LILACS | ID: lil-779444
Biblioteca responsável: CO176.1
RESUMEN

Resultados:

se encontró un 80% de los estetoscopios contaminados, con una mediana de colonización de 2.58 Unidades Formadoras de Colonias (UFC)/cm2 y un 100% de los teléfonos móviles contaminados con una mediana de 0.401 UFC/cm2. En estetoscopios se aislaron SAMR (n=3) y Enterobacterias resistentes a cefalosporinas de tercera generación (n=2). En teléfonos móviles se aislaron SAMR(n=1), Candida spp (n=1) y Enterobacterias (n=5). La encuesta permitió establecer una tendencia de hábitos de higiene inapropiados sobre el uso de los fómites.

Conclusiones:

el hallazgo de bacterias resistentes en estos fómites los convierte en fuentes potenciales de transmisión cruzada y de brotes de infección intrahospitalaria. Estos resultados deben orientar el desarrollo de protocolos para el uso racional de dispositivos médicos y tecnología portátil dentro de ambientes hospitalarios.
ABSTRACT

Results:

80% of the stethoscopes (n=40) were found contaminated with a median count of 2,58 CFU/cm2 meanwhile 100% of cellular phones where found contaminated with a median count of 0,401 CFU/cm2. MRSA (n=3) and third generation cephalosporin-resistant Enterobacteriaceae (n=2) were isolated from stethoscopes, whereas in cellular phones MRSA (n=1), Candida (n=1) and third generation cephalosporin-sensitive Enterobacteriaceae (n=5) where found. Survey results indicated a trend towards inappropriate hygiene habits with fomites; however no statistical correlation could be established between these habits and colonization.

Conclusion:

The finding of nosocomial pathogens in these fomites transforms them in potential sources of crosscontamination and hospital-acquired infections outbreaks. Present results must steer development of protocols for rational use of medical devices and portable technology gadgets within hospital controlled environments.
Assuntos

Texto completo: Disponível Coleções: Bases de dados internacionais Contexto em Saúde: Doenças Negligenciadas Problema de saúde: Doenças Negligenciadas / Zoonoses Base de dados: LILACS Assunto principal: Staphylococcus aureus / Unidades de Terapia Intensiva Neonatal / Infecção Hospitalar / Controle de Infecções / Enterobacteriaceae Limite: Feminino / Humanos / Masculino Idioma: Espanhol Revista: Rev. salud bosque Assunto da revista: Medicina Ano de publicação: 2011 Tipo de documento: Artigo
Texto completo: Disponível Coleções: Bases de dados internacionais Contexto em Saúde: Doenças Negligenciadas Problema de saúde: Doenças Negligenciadas / Zoonoses Base de dados: LILACS Assunto principal: Staphylococcus aureus / Unidades de Terapia Intensiva Neonatal / Infecção Hospitalar / Controle de Infecções / Enterobacteriaceae Limite: Feminino / Humanos / Masculino Idioma: Espanhol Revista: Rev. salud bosque Assunto da revista: Medicina Ano de publicação: 2011 Tipo de documento: Artigo
...