Your browser doesn't support javascript.
loading
The impact of tibial torsion measurements on gait analysis kinematics
Lucareli, Paulo Roberto Garcia; Santos, Nadia Maria; Godoy, Wagner de; Bernal, Milena Moreira Barreto; Paes, Ângela Tavares; Ramalho Junior, Amancio.
Afiliação
  • Lucareli, Paulo Roberto Garcia; Universidade Nove de Julho. São Paulo. BR
  • Santos, Nadia Maria; Universidade de São Paulo. São Paulo. BR
  • Godoy, Wagner de; Hospital Israelita Albert Einstein. São Paulo. BR
  • Bernal, Milena Moreira Barreto; Hospital Israelita Albert Einstein. São Paulo. BR
  • Paes, Ângela Tavares; Universidade Federal de São Paulo. São Paulo. BR
  • Ramalho Junior, Amancio; Hospital Israelita Albert Einstein. São Paulo. BR
Acta ortop. bras ; 22(5): 278-282, Sep-Oct/2014. ilus, tab, graf
Artigo em Inglês, Português | LILACS | ID: lil-783277
Biblioteca responsável: BR734.1
RESUMO
Medir e comparar os valores de torção tibial avaliadospor goniometria e cinemática tridimensional. O impacto de cadamedida sobre os resultados cinemáticos e cinéticos para a marchanormal foi determinado.

Métodos:

Vinte e três pacientes saudáveise independentes para locomoção foram avaliados, 11 mulheres e12 homens, entre 20 a 40 anos de idade. Os dados foram coletadosno Laboratório de Análise do Movimento com 10 câmeras eduas plataformas de força. Medições da torção tibial foram obtidasutilizando a goniometria e a cinemática tridimensional oriunda domodelo de plug-in gait. Posteriormente, ambos os procedimentosforam comparados, e o impacto de cada resultado foi avaliado nacinemática e cinética do joelho e tornozelo.

Resultados:

o coeficientede correlação linear de Pearson (r = 0,504) mostrou umacorrelação moderada entre a cinemática tridimensional e goniometriae entre as mudanças nas medidas. Em relação aos resultadoscinemáticos e cinéticos processados para cada posiçãode torção, não foram observadas diferenças significativas entrenenhuma das variáveis estudadas (p ≥ 0,05).

Conclusão:

Apesarde correlação estatística entre os ângulos de torção da tíbia porgoniometria e cinemática tridimensional terem sido moderada, aanálise cinemática e cinética das articulações não revelou altera-ções significativas. Nível de Evidência I, Estudos Diagnósticos- Investigação de Um Exame Para Diagnóstico...
ABSTRACT
To measure and compare tibial torsion values as assessedby goniometry and three-dimensional kinematics. In addition,the impact of each one of these measurements on kinematic andkinetic results for normal gait was determined.

Methods:

Twenty--three healthy and fully ambulatory patients were assessed, 11women and 12 men, from 20 to 40 years old. Data were collectedat a laboratory for the three-dimensional analysis of movement with10 cameras and two force plates. Tibial torsion measurementswere obtained using goniometry and three-dimensional kinematicsbased on the Plug-in Gait model. Afterwards, both procedureswere compared, and the impact of each result was assessed onthe kinematic and kinetic modeling of the knee and ankle.

Results:

Pearson’s linear correlation coefficient (r=0,504) showed amoderate correlation between the three-dimensional kinematicsand goniometry, and between the changes in the measurements.Regarding the processed kinematic and kinetic results for everytorsion position, no significant differences were noticed amongany of the studied variables (p≥0.05).

Conclusion:

Although statisticalcorrelation among tibial torsion angles by goniometry andthree-dimensional kinematic were moderate, kinematic and kineticanalysis of the joints did not reveal any significant changes.Level of Evidence I, Diagnostic Studies - Investigating a Diagnostic Test...
Assuntos


Texto completo: Disponível Coleções: Bases de dados internacionais Base de dados: LILACS Assunto principal: Tíbia / Anormalidade Torcional / Fenômenos Biomecânicos / Marcha / Articulação do Joelho / Articulação do Tornozelo Limite: Adulto / Feminino / Humanos / Masculino Idioma: Inglês / Português Revista: Acta ortop. bras Assunto da revista: Ortopedia Ano de publicação: 2014 Tipo de documento: Artigo País de afiliação: Brasil Instituição/País de afiliação: Hospital Israelita Albert Einstein/BR / Universidade Federal de São Paulo/BR / Universidade Nove de Julho/BR / Universidade de São Paulo/BR

Texto completo: Disponível Coleções: Bases de dados internacionais Base de dados: LILACS Assunto principal: Tíbia / Anormalidade Torcional / Fenômenos Biomecânicos / Marcha / Articulação do Joelho / Articulação do Tornozelo Limite: Adulto / Feminino / Humanos / Masculino Idioma: Inglês / Português Revista: Acta ortop. bras Assunto da revista: Ortopedia Ano de publicação: 2014 Tipo de documento: Artigo País de afiliação: Brasil Instituição/País de afiliação: Hospital Israelita Albert Einstein/BR / Universidade Federal de São Paulo/BR / Universidade Nove de Julho/BR / Universidade de São Paulo/BR
...