Your browser doesn't support javascript.
loading
Correlação entre fleximetria e goniometria radiológica para avaliações da amplitude articular estática do cotovelo / Correlation between fleximetry and radiological goniometryfor assessment of static elbow range of motion
Silva, Rodrigo Luis Ferreira da; Coelho, Renato Ramos; Vale, Rodrigo Gomes de Souza; Dantas, Estélio.
Afiliação
  • Silva, Rodrigo Luis Ferreira da; UEPA. Belém. BR
  • Coelho, Renato Ramos; Universidade Presidente Antônio Carlos. Barbacena. BR
  • Vale, Rodrigo Gomes de Souza; Universidade Estácio de Sá. Rio de Janeiro. BR
  • Dantas, Estélio; CNPQ. Rio de Janeiro. BR
Fisioter. Bras ; 12(5): 359-364, set.-out. 2011. ilus, tab
Artigo em Português | LILACS | ID: lil-785330
Biblioteca responsável: BR1561.1
RESUMO
Este estudo objetivou determinar o grau de confiabilidade intra e interexaminador de avaliações realizadas por meio de fleximetria,e o seu grau de correlação com avaliações realizadas porgoniometria radiológica. 10 indivíduos tiveram seu cotovelo direito estabilizado por chapas de ferro em ângulo fixo, que foi mensuradopor 04 fisioterapeutas, com o uso de um flexímetro, em 3 dias diferentes com intervalo de uma semana entre os mesmos. Após estas avaliações, os cotovelos foram radiografados, com o mesmo ângulo estabilizado, para análise pela goniometria radiológica. Estas medidas apresentaram baixa confiabilidade intraexaminador (0,23;p = 0,00) e interexaminador (0,38; p = 0,04). As medidas obtidas pela fleximetria apresentaram melhores resultados na análise da confiabilidade interexaminador do que intraexaminador, fato este que possivelmente foi influenciado pelo longo intervalo de tempo entre as avaliações (7 dias). Observou-se também baixa correlação entre afleximetria e a goniometria radiológica (r = 0,10) corroborando com inúmeros outros estudos. O teste t indicou ainda que houve uma diferença significante entre as médias obtidas pelas duas técnicas (p= 0,00). Estes resultados sugerem que o intervalo de 07 dias, pode ter dificultado a reprodutibilidade das medidas pelos examinadores e que a diferença processual entre as técnicas investigadas contribuiu para a ausência de correlação entre suas médias.
ABSTRACT
This study aimed to determinate the intra and inter-reliability of assessments using the fleximetry, and to correlate with radiologic algoniometry assessment. 10 subjects had their right elbow stabilized by fixed iron angle plates, which was measured by 4 physical therapists, using a Fleximeter, on 3 different days with one weekinterval between them. After these evaluations, the elbows were radiographed with the same angle stabilized for radiological analysis by goniometry. These measures had low reliability intra examiner(0.23, p = 0.00) and inter (0.38, p = 0.04). The measurements obtainedby fleximetry showed better results in the analysis of reliability than inter intra-examiner, a fact that was possibly influenced by the long interval between assessments (7 days). It was also observed lowcorrelation between the radiological fleximetry and goniometry(r = 0.10), which corroborates numerous other studies. The t test also indicated that there was a significant difference between themeans obtained by both techniques (p = 0.00). These results suggestthat the interval of 7 days may have hampered the reproducibility of the examiners and that the procedural difference between the research techniques contributed to the lack of correlation between their averages.
Assuntos

Buscar no Google
Coleções: Bases de dados internacionais Base de dados: LILACS Assunto principal: Radiografia / Articulação do Cotovelo / Artrometria Articular Tipo de estudo: Estudo diagnóstico Limite: Humanos Idioma: Português Revista: Fisioter. Bras Assunto da revista: MEDICINA FISICA E REABILITACAO Ano de publicação: 2011 Tipo de documento: Artigo País de afiliação: Brasil Instituição/País de afiliação: CNPQ/BR / UEPA/BR / Universidade Estácio de Sá/BR / Universidade Presidente Antônio Carlos/BR
Buscar no Google
Coleções: Bases de dados internacionais Base de dados: LILACS Assunto principal: Radiografia / Articulação do Cotovelo / Artrometria Articular Tipo de estudo: Estudo diagnóstico Limite: Humanos Idioma: Português Revista: Fisioter. Bras Assunto da revista: MEDICINA FISICA E REABILITACAO Ano de publicação: 2011 Tipo de documento: Artigo País de afiliação: Brasil Instituição/País de afiliação: CNPQ/BR / UEPA/BR / Universidade Estácio de Sá/BR / Universidade Presidente Antônio Carlos/BR
...