Grado de microfiltración de un sellante resinoso con diferentes sistemas adhesivos / Microleakage of a resin sealan using diferents adhesive systems
Licla, K; Albites, U.
Afiliação
  • Licla, K; Universidad Científica del Sur. Escuela de Estomatología. Lima. PE
  • Albites, U; Universidad Científica del Sur. Escuela de Estomatología. Lima. PE
Odontol. pediatr. (Lima) ; 14(2): 120-128, jul.-dic.2015. ilus, tab
Artigo em Espanhol | LILACS, LIPECS | ID: lil-790535
Biblioteca responsável: PE1.1
RESUMEN
Comparar el grado de microfiltración de un sellante resinoso usando sistemas adhesivos de quinta generación, de séptimo generación con y sin acondicionamiento previo de ácido ortofosfórico al 37%. Material y

Métodos:

Se realiz6 un estudio in vitro en 60 premolares humanos, distribuidos aleatoriamente en 4 grupos de 15 elementos cada uno. Grupo 1 (control) ácido ortofosfórico al 37% y sellante; Grupo 2 ácido fosfórico, adhesivo de quinta generación, y sellante; Grupo 3 adhesivo de séptima generación y sellante; Grupo 4 ácido fosfórico, adhesivo de séptima generación y sellante. Posteriormente las muestras fueron sometidas a un termociclaje por 500 ciclos (5° Y 55°C) en altas y bajas temperaturas por 30 segundos; después fueron sumergidas en una solución de azul de metileno al 1% durante 24 horas y seccionadas bucolingualmente y evaluados en un estereomicroscopio a 40x. Se usó la prueba chi cuadrado a un nivel de significancia de 0.05.

Resultados:

En el porcentaje de mayor grado de microfiltraci6n mostró control - sin adhesivo (53,3%), quinta generación (20%), séptima generación (80%) y acondicionamiento con ácido ortofosfórico y adhesivo de séptimo generación (67,7%).

Conclusiones:

El grado de microfiltración del sellante con adhesivo de quinta generación fue menor que usando los otros sistemas adhesivos...
ABSTRACT
To compare the micro leakage of a resin sealant using fifth generation adhesive sys- tems, seventh generation with or without preconditioning of orthophosphoric acid at 37%. Materials and

Methods:

An in vitro study was made on 60 human premolars, randomized into 4 groups of 15 elements each. Group 1 (control) phosphoric acid at 37%, sealant; Group 2 orthophosphoric acid, adhesive of fifth generation, sealant; Group 3 adhesive of seventh generation, sealant; Group 4 orthophosphoric acid, adhesive of seventh generation, sealant. They were put on a thermocycler, 500 cycles (5° y 55T) per 30 seconds on higher and lower temperatures, after that the specimens were drawn for 24 hours on 1 % methylene blue, cut off on a buccolingual way and evaluated on a stereo microscope on 16x. Chi square test was used with a 0.05 significance level.

Results:

The greater percentage of microleakage showed control adhesive without (53.3%), fifth generation (20%), the seventh generation (80%) and conditioning with orthophosphoric acid and adhesive seventh generation (67.7%).

Conclusion:

Microfiltration grade adhesive sealant fifth generation was lower than using the other adhesives...
Assuntos

Texto completo: Disponível Coleções: Bases de dados nacionais / Peru Base de dados: LILACS / LIPECS Assunto principal: Materiais Restauradores do Canal Radicular / Micropeneiramento / Cimentos Dentários Tipo de estudo: Ensaio clínico controlado Limite: Humanos Idioma: Espanhol Revista: Odontol. pediatr. (Lima) Ano de publicação: 2015 Tipo de documento: Artigo Instituição/País de afiliação: Universidad Científica del Sur/PE
Texto completo: Disponível Coleções: Bases de dados nacionais / Peru Base de dados: LILACS / LIPECS Assunto principal: Materiais Restauradores do Canal Radicular / Micropeneiramento / Cimentos Dentários Tipo de estudo: Ensaio clínico controlado Limite: Humanos Idioma: Espanhol Revista: Odontol. pediatr. (Lima) Ano de publicação: 2015 Tipo de documento: Artigo Instituição/País de afiliação: Universidad Científica del Sur/PE
...