ABSTRACT
ABSTRACT Objective:
The purpose of this study was to evaluate the deflection forces of Nitinol orthodontic wires placed in different types of brackets metallic, reinforced polycarbonate with metallic slots, sapphire, passive and active self-ligating, by assessing strength values variation according to gradual increase in wire diameter and deflection and comparing different combinations in the different deflections. Material andMethods:
Specimens were set in a clinical simulation model and evaluated in a Universal Testing Machine (INSTRON 3342), using the ISO 15841 protocol. Data were subjected to One-way ANOVA, followed by Tukey tests (p<0.05).Results:
Self-ligating brackets presented the most similar behavior to each other. For conventional brackets there was no consistent behavior for any of the deflections studied.Conclusions:
Self-ligating brackets presented the most consistent and predictable results while conventional brackets, as esthetic brackets, showed very different patterns of forces. Self-ligating brackets showed higher strength in all deflections when compared with the others, in 0.020-inch wires.
Texto completo:
Disponível
Coleções:
Bases de dados internacionais
Base de dados:
BBO - Odontologia
/
LILACS
Assunto principal:
Fios Ortodônticos
/
Braquetes Ortodônticos
/
Ligas
Tipo de estudo:
Estudo de avaliação
/
Guia de prática clínica
/
Estudo prognóstico
Idioma:
Inglês
Revista:
J. appl. oral sci
Assunto da revista:
Odontologia
Ano de publicação:
2016
Tipo de documento:
Artigo
País de afiliação:
Brasil
Instituição/País de afiliação:
Universidade de São Paulo/BR