Your browser doesn't support javascript.
loading
Ventilation in public housing: implications for indoor nitrogen dioxide concentrations.
Zota, A; Adamkiewicz, G; Levy, J I; Spengler, J D.
Afiliação
  • Zota A; Department of Environmental Health, Harvard School of Public Health, Boston, MA 02215, USA. azota@hsph.harvard.edu
Indoor Air ; 15(6): 393-401, 2005 Dec.
Article em En | MEDLINE | ID: mdl-16268829
ABSTRACT
UNLABELLED Although elevated nitrogen dioxide (NO2) exposures may exacerbate asthma, few studies have examined indoor NO2 levels in low-income, urban neighborhoods, where asthma prevalence is high. As part of the Healthy Public Housing Initiative, NO2 was measured in 77 homes within three Boston public housing developments, using Palmes tubes placed in the kitchen, living room, and outdoors. Air exchange rates (AERs) were assessed using a perfluorocarbon tracer technique. Overall NO2 levels were [mean (ppb)+/-s.d.] kitchen (43+/-20, n=100), living room (36+/-17, n=102), outdoor (19+/-6, n=91). Indoor NO2 levels were significantly higher in the heating season (living room 43 ppb vs. 26 ppb, kitchen 50 ppb vs. 33 ppb), while AERs were significantly lower in the heating season (medians 0.49/h vs. 0.85/h). Significant univariate predictors of indoor concentrations include outdoor NO2 levels, AERs, and occupancy. AERs and outdoor NO2 remained significant in multivariate models (P<0.05). A dummy variable for supplemental heating with gas stove was not significant (P=0.14), but had a large, positive coefficient. Indoor NO2 levels in this cohort are higher than those generally reported in residential US settings, associated in part with increased gas stove usage and decreased AERs during the heating season. PRACTICAL IMPLICATIONS Indoor air quality is mainly a function of outdoor concentrations, indoor sources, ventilation, and residential behavior. Indoor exposures to nitrogen dioxide and other combustion pollutants may be elevated within low-income housing developments due to the presence of multiple sources, poor ventilation, small apartment size, and behavioral responses to apartment conditions (e.g. supplemental heating with gas stove). This information may be used by housing authorities and other landlords to decrease potential environmental stressors, through interventions such as source substitution and improved ventilation, particularly for sensitive sub-populations such as asthmatics.
Assuntos
Buscar no Google
Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Ventilação / Poluição do Ar em Ambientes Fechados / Setor Público / Dióxido de Nitrogênio Tipo de estudo: Etiology_studies / Incidence_studies / Observational_studies / Prognostic_studies / Risk_factors_studies Aspecto: Determinantes_sociais_saude Limite: Humans País/Região como assunto: America do norte Idioma: En Revista: Indoor Air Assunto da revista: SAUDE AMBIENTAL Ano de publicação: 2005 Tipo de documento: Article País de afiliação: Estados Unidos
Buscar no Google
Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Ventilação / Poluição do Ar em Ambientes Fechados / Setor Público / Dióxido de Nitrogênio Tipo de estudo: Etiology_studies / Incidence_studies / Observational_studies / Prognostic_studies / Risk_factors_studies Aspecto: Determinantes_sociais_saude Limite: Humans País/Região como assunto: America do norte Idioma: En Revista: Indoor Air Assunto da revista: SAUDE AMBIENTAL Ano de publicação: 2005 Tipo de documento: Article País de afiliação: Estados Unidos