Your browser doesn't support javascript.
loading
Evaluating How Post-Bronchodilator Vital Capacities Affect the Diagnosis of Obstruction in Pulmonary Function Tests.
Blagev, Denitza P; Sorenson, Dean; Linares-Perdomo, Olinto; Bamberg, Stacy; Hegewald, Matthew; Morris, Alan H.
Afiliação
  • Blagev DP; Intermountain Healthcare, Division of Pulmonary and Critical Care Medicine, Murray, Utah. Denitza.blagev@imail.org.
  • Sorenson D; Division of Pulmonary and Critical Care Medicine, University of Utah, Salt Lake City, Utah.
  • Linares-Perdomo O; Intermountain Healthcare, Division of Pulmonary and Critical Care Medicine, Murray, Utah.
  • Bamberg S; Division of Pulmonary and Critical Care Medicine, University of Utah, Salt Lake City, Utah.
  • Hegewald M; Homer Warner Center for Informatics Research, Murray, Utah.
  • Morris AH; Intermountain Healthcare, Division of Pulmonary and Critical Care Medicine, Murray, Utah.
Respir Care ; 61(11): 1523-1529, 2016 Nov.
Article em En | MEDLINE | ID: mdl-27624631
ABSTRACT

BACKGROUND:

Although the ratio of FEV1 to the vital capacity (VC) is universally accepted as the cornerstone of pulmonary function test (PFT) interpretation, FVC remains in common use. We sought to determine what the differences in PFT interpretation were when the largest measured vital capacity (VCmax) was used instead of the FVC.

METHODS:

We included 12,238 consecutive PFTs obtained for routine clinical care. We interpreted all PFTs first using FVC in the interpretation algorithm and then again using the VCmax, obtained either before or after administration of inhaled bronchodilator.

RESULTS:

Six percent of PFTs had an interpretive change when VCmax was used instead of FVC. The most common changes were new diagnosis of obstruction and exclusion of restriction (previously suggested by low FVC without total lung capacity measured by body plethysmography). A nonspecific pattern occurred in 3% of all PFT interpretations with FVC. One fifth of these 3% produced a new diagnosis of obstruction with VCmax. The largest factors predicting a change in PFT interpretation with VCmax were a positive bronchodilator response and the administration of a bronchodilator. Larger FVCs decreased the odds of PFT interpretation change. Surprisingly, the increased numbers of PFT tests did not increase odds of PFT interpretation change.

CONCLUSIONS:

Six percent of PFTs have a different interpretation when VCmax is used instead of FVC. Evaluating borderline or ambiguous PFTs using the VCmax may be informative in diagnosing obstruction and excluding restriction.
Assuntos
Palavras-chave
Buscar no Google
Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Testes de Função Respiratória / Broncodilatadores / Capacidade Vital / Pneumopatias Obstrutivas Tipo de estudo: Diagnostic_studies / Evaluation_studies / Observational_studies / Prognostic_studies / Risk_factors_studies Limite: Adult / Aged / Aged80 / Female / Humans / Male / Middle aged Idioma: En Revista: Respir Care Ano de publicação: 2016 Tipo de documento: Article País de publicação: EEUU / ESTADOS UNIDOS / ESTADOS UNIDOS DA AMERICA / EUA / UNITED STATES / UNITED STATES OF AMERICA / US / USA
Buscar no Google
Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Testes de Função Respiratória / Broncodilatadores / Capacidade Vital / Pneumopatias Obstrutivas Tipo de estudo: Diagnostic_studies / Evaluation_studies / Observational_studies / Prognostic_studies / Risk_factors_studies Limite: Adult / Aged / Aged80 / Female / Humans / Male / Middle aged Idioma: En Revista: Respir Care Ano de publicação: 2016 Tipo de documento: Article País de publicação: EEUU / ESTADOS UNIDOS / ESTADOS UNIDOS DA AMERICA / EUA / UNITED STATES / UNITED STATES OF AMERICA / US / USA