Your browser doesn't support javascript.
loading
Left ventricular inotropic effect of atrial pacing after coronary artery bypass grafting.
Eichhorn, E J; Diehl, J T; Konstam, M A; Payne, D D; Salem, D N; Cleveland, R J.
Afiliação
  • Eichhorn EJ; Department of Medicine (Cardiology) Tufts University, Boston, Massachusetts.
Am J Cardiol ; 63(11): 687-92, 1989 Mar 15.
Article em En | MEDLINE | ID: mdl-2784282
ABSTRACT
The effect of atrial pacing on left ventricular (LV) performance was studied in 19 patients, 24 hours after coronary artery bypass grafting (CABG). LV volumes were calculated from simultaneous radionuclide-thermodilution measurements at rest (heart rate 82 +/- 12 beats/min), 10 minutes after the start of atrial pacing (100 beats/min), and with atrial pacing plus volume loading to return preload toward baseline. Atrial pacing reduced preload as reflected by LV end-diastolic volume index (69 +/- 14 vs 60 +/- 14 ml/m2, mean +/- standard deviation) (p less than 0.0001), but returned to baseline with volume loading. Afterload, as reflected by arterial end-systolic pressure, did not change with atrial pacing (63 +/- 9 at baseline vs 64 +/- 8 mm Hg with pacing, difference not significant). Afterload increased with volume loading (68 +/- 10 mm Hg, p less than 0.025 vs baseline and pacing). LV stroke volume decreased with atrial pacing due to reduced preload, but returned to baseline with volume loading. Cardiac index increased with atrial pacing and increased further with volume loading. Compared with baseline, LV end-systolic volume index was reduced during atrial pacing both before and after volume loading, despite unchanged or augmented afterload. The combination of atrial pacing and volume loading resulted in augmentation of LV stroke work, despite no increase in preload compared with baseline. Thus, after CABG, increased (paced) heart rate augments inotropic state, as indicated by reduced LV end-systolic volume under conditions of unchanged or increased afterload, and elevated LV stroke work without an increase in preload or a decrease in afterload.
Assuntos
Buscar no Google
Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Estimulação Cardíaca Artificial / Ponte de Artéria Coronária / Contração Miocárdica Limite: Aged / Female / Humans / Male / Middle aged Idioma: En Revista: Am J Cardiol Ano de publicação: 1989 Tipo de documento: Article
Buscar no Google
Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Estimulação Cardíaca Artificial / Ponte de Artéria Coronária / Contração Miocárdica Limite: Aged / Female / Humans / Male / Middle aged Idioma: En Revista: Am J Cardiol Ano de publicação: 1989 Tipo de documento: Article