Equipment-Free Detection of K+ on Microfluidic Paper-Based Analytical Devices Based on Exhaustive Replacement with Ionic Dye in Ion-selective Capillary Sensors.
ACS Sens ; 4(3): 670-677, 2019 03 22.
Artigo em Inglês | MEDLINE | ID: mdl-30702271
ABSTRACT
A distance-based analysis of potassium ion (K+) is introduced that is performed on a microfluidic paper-based analytical device (µPAD) coupled to an ion-selective capillary sensor. The concept is based on two sequential steps, the selective replacement of analyte ion with an ionic dye, and the detection of this dye in a distance-based readout on paper. To achieve the first step, the capillary sensor holds a poly(vinyl chloride) (PVC) membrane film layer plasticized by dioctyl sebacate (DOS) that contains the potassium ionophore valinomycin, a lipophilic cation-exchanger and the ionic indicator Thioflavin T (ThT) on its inner wall. Upon introduction of the sample, K+ in the aqueous sample solution is quantitatively extracted into the film membrane and replaced with ThT. To convert the ion exchange signal into a distance-based analysis, this solution was dropped onto the inlet area of a µPAD to flow the ThT along a channel defined by wax printing, resulting in the electrostatic binding of ThT to the cellulose carboxylic groups. The initial amount of K+ determines the amount of ThT in the aqueous solution after ion-exchange, and consequently the distance of ThT-colored area reflects the sample K+ concentration. The ion exchange reaction was operated in a so-called "exhaustive sensing mode" and gave a distinct response in a narrow range of K+ concentration (1-6 mM) that cannot be achieved by the classical optode sensing mode. The absence of hydrogen ions from the equilibrium competition of the capillary sensor contributed to a complete pH-independence, unlike conventional optodes that contain a pH sensitive indicator. A very high selectivity for K+ over Na+ and Ca2+ has been confirmed in separate solutions and mixed solutions tests. K+ measurements in pooled serum samples at concentrations between 2 and 6 mM are successfully demonstrated on a temperature controlled support.
Assuntos

Similares

MEDLINE

...
LILACS

LIS

Texto completo: Disponível Coleções: Bases de dados internacionais Base de dados: MEDLINE Assunto principal: Papel / Potássio / Técnicas de Química Analítica / Corantes / Dispositivos Lab-On-A-Chip Idioma: Inglês Revista: ACS Sens Ano de publicação: 2019 Tipo de documento: Artigo País de afiliação: Suíça