Fat quantification of the rotator cuff musculature using dual-energy CT-A pilot study.
Baillargeon, Amanda M; Baffour, Francis I; Yu, Lifeng; Fletcher, Joel G; McCollough, Cynthia H; Glazebrook, Katrina N.
Afiliação
  • Baillargeon AM; Department of Radiology, Mayo Clinic, 200 First St. SW, Rochester, MN 55905, United States. Electronic address: Baillargeon.Amanda@mayo.edu.
  • Baffour FI; Department of Radiology, Mayo Clinic, 200 First St. SW, Rochester, MN 55905, United States. Electronic address: baffour.francis@mayo.edu.
  • Yu L; Department of Radiology, Mayo Clinic, 200 First St. SW, Rochester, MN 55905, United States. Electronic address: Yu.Lifeng@mayo.edu.
  • Fletcher JG; Department of Radiology, Mayo Clinic, 200 First St. SW, Rochester, MN 55905, United States. Electronic address: Fletcher.Joel@mayo.edu.
  • McCollough CH; Department of Radiology, Mayo Clinic, 200 First St. SW, Rochester, MN 55905, United States. Electronic address: McCollough.Cynthia@mayo.edu.
  • Glazebrook KN; Department of Radiology, Mayo Clinic, 200 First St. SW, Rochester, MN 55905, United States. Electronic address: Katrina@mayo.edu.
Eur J Radiol ; 130: 109145, 2020 Sep.
Article em En | MEDLINE | ID: mdl-32634758
ABSTRACT

PURPOSE:

To assess the ability of dual-energy CT (DECT) as a novel technique to quantify the degree of rotator cuff fat degeneration.

METHOD:

Clinically indicated shoulder CT exams for evaluation of osteoarthritis, rotator cuff arthropathy, pain or instability, or preoperative planning were acquired using dual-source CT systems. Rotator cuff DECT fat fraction after material decomposition was calculated off the sagittal image. Fat fractions were also assessed using CT numbers from dual energy virtual monochromatic images (70 keV) and single-energy CT (SECT) images (100 kV). Visual subjective Goutallier scores of the rotator cuff muscles were used as the reference standard.

RESULTS:

12 shoulders from 10 patients were analyzed, with bilateral shoulders evaluated in two patients (mean age 69 years (range 19-97)). Three patients were male and seven were female, with mean BMI of 32 (range 26-41). Mean fat fraction of the teres major and subcutaneous fat were, 2.9 % ± 4.0 % and 99.5 % ± 2.6 %, respectively, rendering these as reliable internal standards for 0% and 100 % fat. Mean DECT fat fractions of the rotator cuff were compared to Goutallier scores, revealing a high strength of rank correlation ρ = 0.92, p < 0.0001. Mean fat fraction assessed with CT numbers also revealed high strengths of linear associations ρ = 0.83, p < 0.0001 and ρ = 0.82, p < 0.0001, for DECT 70 keV and SECT 100 kV, respectively.

CONCLUSIONS:

DECT direct fat fraction after material decomposition presents a novel approach to quantitative assessment of fatty degeneration, which has excellent correlation with clinically accepted standards.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Tomografia Computadorizada por Raios X / Lesões do Manguito Rotador Tipo de estudo: Guideline Limite: Adult / Aged / Aged80 / Female / Humans / Male / Middle aged Idioma: En Revista: Eur J Radiol Ano de publicação: 2020 Tipo de documento: Article País de publicação: IE / IRELAND / IRLANDA

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Tomografia Computadorizada por Raios X / Lesões do Manguito Rotador Tipo de estudo: Guideline Limite: Adult / Aged / Aged80 / Female / Humans / Male / Middle aged Idioma: En Revista: Eur J Radiol Ano de publicação: 2020 Tipo de documento: Article País de publicação: IE / IRELAND / IRLANDA