The effect of sandblasting and acid etching on survival rate of orthodontic miniscrews: a split-mouth randomized controlled trial.
Moghaddam, Saeid Foroughi; Mohammadi, Amir; Behroozian, Ahmad.
Afiliação
  • Moghaddam SF; Department of Orthodontics, Faculty of Dentistry, Tabriz University of Medical Sciences, Golgasht Avenue, Tabriz, Iran.
  • Mohammadi A; Department of Orthodontics, Faculty of Dentistry, Tabriz University of Medical Sciences, Golgasht Avenue, Tabriz, Iran.
  • Behroozian A; Department of Orthodontics, Faculty of Dentistry, Tabriz University of Medical Sciences, Golgasht Avenue, Tabriz, Iran. ahmadbehroozian@yahoo.com.
Prog Orthod ; 22(1): 2, 2021 Jan 07.
Artigo em Inglês | MEDLINE | ID: mdl-33409700
ABSTRACT

BACKGROUND:

The aim of this study was to investigate the effect of surface roughening and acid etching on clinical success rate and removal and insertion torque of orthodontic miniscrews. MATERIALS AND

METHODS:

Sixty-two orthodontic miniscrews (Jail Medical Corporation, Seoul, Korea) with the same design and dimensions (10-mm length, 2-mm diameter) are divided into two (sandblasted and acid-etched versus control) groups. The sample of the study was 31 patients whose miniscrews were needed for en masse retraction of the upper six anterior teeth. In this split-mouth study, the miniscrews were placed in the attached gingiva between the second premolar and the first molar. The side (left or right) was selected randomly. The miniscrews were loaded 6 weeks after insertion, and the patients were followed up after 3, 6, 10, 14, and 18 weeks and then for 4 weeks interval. Chi-square, correlation, and independent t tests were done using SPSS ver24 to interpret the data.

RESULTS:

The survival rate was 90.3% and 83.9% for the sandblasted and acid-etched versus the control group, respectively. The difference in survival rate was not statistically significant (p > 0.05). Removal torque was higher for the sandblasted group (p < 0.05). Younger patients showed less survival rate (p < 0.05) in both groups. Insertion side, namely, left or right, was not statistically significant.

CONCLUSIONS:

Although sandblasting increased removal torque, it did not influence the survival rate of orthodontic miniscrews significantly.
Assuntos
Texto completo: Disponível Coleções: Bases de dados internacionais Base de dados: MEDLINE Assunto principal: Procedimentos de Ancoragem Ortodôntica Tipo de estudo: Ensaio clínico controlado / Estudo observacional Limite: Humanos Idioma: Inglês Revista: Prog Orthod Assunto da revista: Odontologia Ano de publicação: 2021 Tipo de documento: Artigo País de afiliação: Irã

Similares

MEDLINE

...
LILACS

LIS

Texto completo: Disponível Coleções: Bases de dados internacionais Base de dados: MEDLINE Assunto principal: Procedimentos de Ancoragem Ortodôntica Tipo de estudo: Ensaio clínico controlado / Estudo observacional Limite: Humanos Idioma: Inglês Revista: Prog Orthod Assunto da revista: Odontologia Ano de publicação: 2021 Tipo de documento: Artigo País de afiliação: Irã