Targeting the Rat's Small Bowel: Long-Term Infusion into the Superior Mesenteric Artery.
Borrello, Alessandro; Agnes, Amedea Luciana; Pellegrino, Eleonora; Magalini, Sabina; Gui, Daniele.
Afiliação
  • Borrello A; Department of Emergency Surgery, Università Cattolica del S. Cuore; alebor93@gmail.com.
  • Agnes AL; Department of Emergency Surgery, Università Cattolica del S. Cuore.
  • Pellegrino E; Department of Emergency Surgery, Università Cattolica del S. Cuore.
  • Magalini S; Department of Emergency Surgery, Università Cattolica del S. Cuore.
  • Gui D; Department of Emergency Surgery, Università Cattolica del S. Cuore.
J Vis Exp ; (170)2021 04 08.
Article em En | MEDLINE | ID: mdl-33900283
ABSTRACT
The superior mesenteric artery can be cannulated in humans through minimally invasive radiological catheterization of the femoral or axillary artery. SMA cannulation is more difficult in rats due to small anatomical dimensions. The aim of the study is to describe a surgical technique for cannulation of the SMA in rats to perform long-term infusion of drugs into the SMA vascular bed in unrestricted animals, which will result in a high rate of catheter patency after the post surgical recovery for 24 hours. To avoid the risk of SMA thrombosis or bleeding from direct access, a proximal branch of the SMA is isolated, ligated distally and cannulated with a 0.25 mm polyurethane capillary tube whose tip is advanced close to the origin of the SMA from the aorta. The cannula is then tunnelled subcutaneously to the back of the animal's neck and through the skin via an artificial valve. The external portion of the cannula is inserted in a semi-rigid support system and connected to the continuous infusion pump outside the cage where the rat is free to move. Correct positioning of the cannula was demonstrated by post-surgical angiography and autopsy findings. Catheter patency after 24 hours of saline infusion into the SMA region was assured in most rats by the total discharge of the pump and recognition of a functional cannula for blood sampling or saline infusion.
Assuntos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Cateterismo / Artéria Mesentérica Superior Limite: Animals Idioma: En Revista: J Vis Exp Ano de publicação: 2021 Tipo de documento: Article País de publicação: EEUU / ESTADOS UNIDOS / ESTADOS UNIDOS DA AMERICA / EUA / UNITED STATES / UNITED STATES OF AMERICA / US / USA

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Cateterismo / Artéria Mesentérica Superior Limite: Animals Idioma: En Revista: J Vis Exp Ano de publicação: 2021 Tipo de documento: Article País de publicação: EEUU / ESTADOS UNIDOS / ESTADOS UNIDOS DA AMERICA / EUA / UNITED STATES / UNITED STATES OF AMERICA / US / USA