Your browser doesn't support javascript.
loading
Interventional cardiac magnetic resonance imaging: current applications, technology readiness level, and future perspectives.
Rier, Sophie C; Vreemann, Suzan; Nijhof, Wouter H; van Driel, Vincent J H M; van der Bilt, Ivo A C.
Afiliação
  • Rier SC; Cardiology Division, Department of Cardiology, Haga Teaching Hospital, Els Borst-Eilersplein 275, Postbus 40551, The Hague 2504 LN, The Netherlands.
  • Vreemann S; Department of Cardiology, Haga Teaching Hospital, The Hague, The Netherlands Siemens Healthineers Nederland B.V., Den Haag, The Netherlands.
  • Nijhof WH; Siemens Healthineers Nederland B.V., Den Haag, The Netherlands.
  • van Driel VJHM; Department of Cardiology, Haga Teaching Hospital, The Hague, The Netherlands.
  • van der Bilt IAC; Department of Cardiology, Haga Teaching Hospital, The Hague, The Netherlands.
Ther Adv Cardiovasc Dis ; 16: 17539447221119624, 2022.
Article em En | MEDLINE | ID: mdl-36039865
ABSTRACT

BACKGROUND:

Cardiac magnetic resonance (CMR) provides excellent temporal and spatial resolution, tissue characterization, and flow measurements. This enables major advantages when guiding cardiac invasive procedures compared with X-ray fluoroscopy or ultrasound guidance. However, clinical implementation is limited due to limited availability of technological advancements in magnetic resonance imaging (MRI) compatible equipment. A systematic review of the available literature on past and present applications of interventional MR and its technology readiness level (TRL) was performed, also suggesting future applications.

METHODS:

A structured literature search was performed using PubMed. Search terms were focused on interventional CMR, cardiac catheterization, and other cardiac invasive procedures. All search results were screened for relevance by language, title, and abstract. TRL was adjusted for use in this article, level 1 being in a hypothetical stage and level 9 being widespread clinical translation. The papers were categorized by the type of procedure and the TRL was estimated.

RESULTS:

Of 466 papers, 117 papers met the inclusion criteria. TRL was most frequently estimated at level 5 meaning only applicable to in vivo animal studies. Diagnostic right heart catheterization and cavotricuspid isthmus ablation had the highest TRL of 8, meaning proven feasibility and efficacy in a series of humans.

CONCLUSION:

This article shows that interventional CMR has a potential widespread application although clinical translation is at a modest level with TRL usually at 5. Future development should be directed toward availability of MR-compatible equipment and further improvement of the CMR techniques. This could lead to increased TRL of interventional CMR providing better treatment.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Imagem por Ressonância Magnética Intervencionista Tipo de estudo: Guideline / Prognostic_studies / Systematic_reviews Limite: Animals / Humans Idioma: En Revista: Ther Adv Cardiovasc Dis Assunto da revista: ANGIOLOGIA / CARDIOLOGIA / TERAPEUTICA Ano de publicação: 2022 Tipo de documento: Article País de afiliação: Holanda

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Imagem por Ressonância Magnética Intervencionista Tipo de estudo: Guideline / Prognostic_studies / Systematic_reviews Limite: Animals / Humans Idioma: En Revista: Ther Adv Cardiovasc Dis Assunto da revista: ANGIOLOGIA / CARDIOLOGIA / TERAPEUTICA Ano de publicação: 2022 Tipo de documento: Article País de afiliação: Holanda