Your browser doesn't support javascript.
loading
Finite element analysis of a customized implant in PMMA coupled with the cranial bone.
Moncayo-Matute, F P; Torres-Jara, P B; Vázquez-Silva, E; Peña-Tapia, P G; Moya-Loaiza, D P; Abad-Farfán, G.
Afiliação
  • Moncayo-Matute FP; Research Group on New Materials and Transformation Processes (GIMAT-acronym in Spanish), Universidad Politécnica Salesiana (UPS), Cuenca, Azuay, Ecuador.
  • Torres-Jara PB; Research Group on New Materials and Transformation Processes (GIMAT-acronym in Spanish), Universidad Politécnica Salesiana (UPS), Cuenca, Azuay, Ecuador.
  • Vázquez-Silva E; Research Group on New Materials and Transformation Processes (GIMAT-acronym in Spanish), Universidad Politécnica Salesiana (UPS), Cuenca, Azuay, Ecuador. Electronic address: evazquez@ups.edu.ec.
  • Peña-Tapia PG; Department of Neurosurgery/Society for the Fight Against Cancer, SOLCA Cancer Institute, Cuenca, Azuay, Ecuador.
  • Moya-Loaiza DP; Research Group on New Materials and Transformation Processes (GIMAT-acronym in Spanish), Universidad Politécnica Salesiana (UPS), Cuenca, Azuay, Ecuador.
  • Abad-Farfán G; Research Group on New Materials and Transformation Processes (GIMAT-acronym in Spanish), Universidad Politécnica Salesiana (UPS), Cuenca, Azuay, Ecuador.
J Mech Behav Biomed Mater ; 146: 106046, 2023 10.
Article em En | MEDLINE | ID: mdl-37562162
ABSTRACT
This computational study investigates the effect of the Von Misses stresses and deformations distribution generated by coupling a customized cranial implant with its fixation system for anchoring in the cranial bone of a specific patient. Three simulations were carried out under static loads, in different areas of the implant and during the rest-activity; and another three simulations were considered preset maximum intracranial pressures. Anatomical models were obtained by computed tomography. The design of the device to be implanted was carried out by applying reverse engineering processes, from the corresponding computer-aided design (CAD) model of the bone structure of interest. Likewise, the anchoring system was modeled in detail. Loads were applied at three points on the custom implant. The stress distribution on the artificial plate and the implant-natural bone interface was analyzed. The distribution of the stresses caused by the internal load states on the plate and the anchoring system was also studied. The neurocranial reconstruction with the customized polymethylmethacrylate (PMMA)-based implant and the finite element analysis demonstrated that the fixation and coupling system of the bone-implant interface guarantees adequate protection for the internal structures of the restored area. In addition, the custom-designed and placed implant will not cause non-physiological harm to the patient. Nor will failures occur in the anchoring system.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Implantes Dentários / Polimetil Metacrilato Limite: Humans Idioma: En Revista: J Mech Behav Biomed Mater Assunto da revista: ENGENHARIA BIOMEDICA Ano de publicação: 2023 Tipo de documento: Article País de afiliação: Equador País de publicação: HOLANDA / HOLLAND / NETHERLANDS / NL / PAISES BAJOS / THE NETHERLANDS

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Implantes Dentários / Polimetil Metacrilato Limite: Humans Idioma: En Revista: J Mech Behav Biomed Mater Assunto da revista: ENGENHARIA BIOMEDICA Ano de publicação: 2023 Tipo de documento: Article País de afiliação: Equador País de publicação: HOLANDA / HOLLAND / NETHERLANDS / NL / PAISES BAJOS / THE NETHERLANDS