The dual sugar test (lactulose plus mannitol) is an unreliable indicator of feed withdrawal-associated changes in intestinal permeability in broiler chickens.
White, Cameron S; Bauer, Laura L; Dilger, Ryan N.
Afiliação
  • Sujiyanto; Division of Nutritional Sciences, University of Illinois, Urbana, IL 61801, USA.
  • White CS; Department of Animal Sciences, University of Illinois, Urbana, IL 61801, USA.
  • Bauer LL; Department of Animal Sciences, University of Illinois, Urbana, IL 61801, USA.
  • Dilger RN; Division of Nutritional Sciences, University of Illinois, Urbana, IL 61801, USA; Department of Animal Sciences, University of Illinois, Urbana, IL 61801, USA. Electronic address: rdilger2@illinois.edu.
Poult Sci ; 103(2): 103336, 2024 Feb.
Article em En | MEDLINE | ID: mdl-38103531
ABSTRACT
Despite its importance in poultry research, there is lack of standardized and practical techniques to measure intestinal permeability in a noninvasive manner. Therefore, this research sought to standardize a procedure using lactulose (Lac) and mannitol (Man) to measure intestinal barrier function in broilers. Twenty-one-day-old male and female Ross 308 birds were orally gavaged (either 2 mL/kg BW or fixed 3 mL per bird) with a solution containing 5 to 25 g Lac and 1 to 5 g Man dissolved in pure water to reach 100 mL of final solution. Feed withdrawal (FW; 2-24-h duration) prior to dosing with Lac and Man (LacMan) was mainly used to induce graded intestinal permeability. Blood samples were collected at 60-, 90-, or 120-min after LacMan dosing using serum or plasma (K2EDTA and/or Na-Heparin) blood tubes. Lac and Man concentrations were quantified by HPLC. Plasma samples collected 90-min after LacMan dosing elicited the least variable response (22.4% vs. 22.8% or 23.4% CV when compared with 60- and 120-min sampling time-points, respectively), and both markers were detectable after administering a solution containing the lowest concentration of Lac and Man. However, analytical problems arose when using Na-Heparin anticoagulant as high glucose levels interfered with Lac quantification. Upon improving the chromatographic technique, it became evident that a 24-h FW increased (P < 0.01) Lac concentrations. In the last trial, a more severe glucose interference was observed, resulting in no Lac detection within an entire treatment group. Twelve hours of FW increased (P < 0.01) Man concentration in the plasma of birds receiving the solution containing 3 g Man, but had no effect on the birds receiving the solution containing 5 g Man. A 24-h FW did not affect the Man concentrations in birds receiving the solution containing either 3 or 5 g Man. With inconsistency of Lac detection throughout our trials, it was concluded that the combination of Lac and Man is an unreliable marker to predict intestinal barrier function in broilers.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Galinhas / Lactulose Limite: Animals / Female / Humans / Male Idioma: En Revista: Poult Sci Ano de publicação: 2024 Tipo de documento: Article País de afiliação: Estados Unidos País de publicação: Reino Unido

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Galinhas / Lactulose Limite: Animals / Female / Humans / Male Idioma: En Revista: Poult Sci Ano de publicação: 2024 Tipo de documento: Article País de afiliação: Estados Unidos País de publicação: Reino Unido