Your browser doesn't support javascript.
loading
Allosteric strand displacement isothermal amplification for the visual detection of Toxoplasma gondii in 30 minutes.
Wang, Lei; Zhang, Zhaoxuan; Liu, Yanger; Lin, Shenghao; Zhang, Wenqiang; Zhu, Longjiao; Xu, Wentao; Dong, Yulan.
Afiliação
  • Wang L; Department of Basic Veterinary Medicine, College of Veterinary Medicine, China Agricultural University, Beijing, 100193, China.
  • Zhang Z; Department of Mechanical Engineering, College of Engineering, China Agricultural University, Beijing, 100083, China.
  • Liu Y; Department of Basic Veterinary Medicine, College of Veterinary Medicine, China Agricultural University, Beijing, 100193, China.
  • Lin S; Food Laboratory of Zhongyuan, Key Laboratory of Precision Nutrition and Food Quality, Department of Nutrition and Health, China Agricultural University, Beijing, 100083, China.
  • Zhang W; Department of Mechanical Engineering, College of Engineering, China Agricultural University, Beijing, 100083, China.
  • Zhu L; Food Laboratory of Zhongyuan, Key Laboratory of Precision Nutrition and Food Quality, Department of Nutrition and Health, China Agricultural University, Beijing, 100083, China.
  • Xu W; Food Laboratory of Zhongyuan, Key Laboratory of Precision Nutrition and Food Quality, Department of Nutrition and Health, China Agricultural University, Beijing, 100083, China. Electronic address: xuwentao@cau.edu.cn.
  • Dong Y; Department of Basic Veterinary Medicine, College of Veterinary Medicine, China Agricultural University, Beijing, 100193, China. Electronic address: ylbcdong@cau.edu.cn.
Biosens Bioelectron ; 251: 116132, 2024 May 01.
Article em En | MEDLINE | ID: mdl-38382270
ABSTRACT
Early detection of Toxoplasma gondii (T. gondii) is critical due to a lack of effective treatment for toxoplasmosis.This study established a simple, cost-effective, and rapid colorimetric detection method for T. gondii. The entire testing process, from sample collection to results, takes only 0.5 h. These characteristics fulfill the demands of researchers seeking rapid target detection with minimal equipment reliance. For genomic extraction, this study evaluated the ability of two filter papers to capture genomes. A rapid genomic extraction device combined with the two filter papers was designed to simplify the genomic extraction process, which was completed within 10 min and increased the detection sensitivity tenfold. The method utilized a simplified primer design for isothermal amplification, namely allosteric strand displacement (ASD), and employed an underutilized commercial color indicator, Bromothymol Blue (BTB), for signal output. Compared with other reported indicators, BTB exhibited a more pronounced color change, shifting from blue to yellow in positive samples, facilitating easier visual differentiation. The reaction was completed in 20 min with a limit of detection (LOD) as low as 0.014 T. gondii per microliter.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Toxoplasma / Técnicas Biossensoriais Idioma: En Revista: Biosens Bioelectron Assunto da revista: BIOTECNOLOGIA Ano de publicação: 2024 Tipo de documento: Article País de afiliação: China País de publicação: Reino Unido

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Toxoplasma / Técnicas Biossensoriais Idioma: En Revista: Biosens Bioelectron Assunto da revista: BIOTECNOLOGIA Ano de publicação: 2024 Tipo de documento: Article País de afiliação: China País de publicação: Reino Unido