Your browser doesn't support javascript.
loading
A novel immunocomplex capture fluorescence assay (ICFA) using fluorescent beads and transfected cells for specific identification of human neutrophil antigen (HNA)-1a and -1b antibodies.
Kamada, Hiromi; Takahashi, Daisuke; Shimizu, Marie; Uchida, Miyuki; Watanabe, Yoshihisa; Nakajima, Fumiaki; Miyata, Shigeki; Satake, Masahiro.
Afiliação
  • Kamada H; Central Blood Institute, Blood Service Headquarters, Japanese Red Cross Society, Tokyo, Japan.
  • Takahashi D; Central Blood Institute, Blood Service Headquarters, Japanese Red Cross Society, Tokyo, Japan.
  • Shimizu M; Central Blood Institute, Blood Service Headquarters, Japanese Red Cross Society, Tokyo, Japan.
  • Uchida M; Central Blood Institute, Blood Service Headquarters, Japanese Red Cross Society, Tokyo, Japan.
  • Watanabe Y; Central Blood Institute, Blood Service Headquarters, Japanese Red Cross Society, Tokyo, Japan.
  • Nakajima F; GenoDive Pharma Inc., Atsugi, Kanagawa, Japan.
  • Miyata S; Central Blood Institute, Blood Service Headquarters, Japanese Red Cross Society, Tokyo, Japan.
  • Satake M; Central Blood Institute, Blood Service Headquarters, Japanese Red Cross Society, Tokyo, Japan.
Transfusion ; 64(5): 906-918, 2024 May.
Article em En | MEDLINE | ID: mdl-38530740
ABSTRACT

BACKGROUND:

To identify specific human neutrophil antigen (HNA) antibodies, assays using neutrophils such as monoclonal antibody-specific immobilization of granulocyte antigens (MAIGA) are recommended. However, these assays are limited by labor-intensive neutrophil preparation and varying antigen expression levels.

METHODS:

We evaluated a newly developed immunocomplex capture fluorescence assay (ICFA) for identifying HNA-1 antibodies and compared it to MAIGA and LABScreen Multi (LABM), which utilizes recombinant HNA-coated Luminex beads. For ICFA, HNA-1a or HNA-1b transfected cells replaced neutrophils. Cells incubated with serum were lysed, and immune complexes were captured using five CD16 monoclonal antibody-conjugated Luminex beads. Nine antisera with known specificity and 26 samples suspected of containing HNA antibodies were analyzed by ICFA and MAIGA using neutrophils or transfected cells (ICFA-N or ICFA-T, and MAIGA-N or MAIGA-T, respectively).

RESULTS:

ICFA-T and MAIGA-N accurately determined the specificity of all antibodies in the nine antiserum samples. The ICFA-T detection limit was 2048-fold for anti-HNA-1a and 256-fold for anti-HNA-1b; the limits of MAIGA-T, MAIGA-N, and LABM were 32-, 4 ~ 64-, and 128-fold for anti-HNA-1a and 64-, 16 ~ 64-, and 32-fold for anti-HNA-1b, respectively. Twelve and 7 of the remaining 26 samples tested negative and positive, respectively, in both ICFA-T and MAIGA-N. Antibody specificity against HNA-1a or HNA-1b determined using ICFA-T agreed with that determined using MAIGA-N and LABM. Another seven samples tested positive in ICFA-T but negative in MAIGA-N.

CONCLUSION:

The novel ICFA is highly sensitive and exhibits specificity similar to MAIGA and LABM for detecting HNA-1 antibodies.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Imunoensaio / Isoantígenos / Neutrófilos Limite: Humans Idioma: En Revista: Transfusion Ano de publicação: 2024 Tipo de documento: Article País de afiliação: Japão País de publicação: Estados Unidos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Imunoensaio / Isoantígenos / Neutrófilos Limite: Humans Idioma: En Revista: Transfusion Ano de publicação: 2024 Tipo de documento: Article País de afiliação: Japão País de publicação: Estados Unidos