Your browser doesn't support javascript.
loading
Disposable graphene-oxide screen-printed electrode integrated with portable device for detection of SARS-CoV-2 in clinical samples.
Ramya, P R; Halder, Sayanti; Nagamani, K; Singh Chouhan, Raghuraj; Gandhi, Sonu.
Afiliação
  • Ramya PR; DBT-National Institute of Animal Biotechnology (NIAB), Hyderabad 500032, Telangana, India; DBT-Regional Centre for Biotechnology (RCB), Faridabad 121001, Haryana, India.
  • Halder S; DBT-National Institute of Animal Biotechnology (NIAB), Hyderabad 500032, Telangana, India.
  • Nagamani K; Department of Microbiology, Gandhi Medical College, Gandhi Hospital, Hyderabad 500025, Telangana, India.
  • Singh Chouhan R; Department of Environmental Sciences, Jozef Stefan Institute, Jamova Cesta 39, 1000 Ljubljana, Slovenia.
  • Gandhi S; DBT-National Institute of Animal Biotechnology (NIAB), Hyderabad 500032, Telangana, India; DBT-Regional Centre for Biotechnology (RCB), Faridabad 121001, Haryana, India. Electronic address: gandhi@niab.org.in.
Bioelectrochemistry ; 158: 108722, 2024 Aug.
Article em En | MEDLINE | ID: mdl-38697015
ABSTRACT
Severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) diagnosis is the need of the hour, as cases are persistently increasing, and new variants are constantly emerging. The ever-changing nature of the virus leading to multiple variants, has brought an imminent need for early, accurate and rapid detection methods. Herein, we have reported the design and fabrication of Screen-Printed Electrodes (SPEs) with graphene oxide (GO) as working electrode and modified with specific antibodies for SARS-CoV-2 Receptor Binding Domain (RBD). Flexibility of design, and portable nature has made SPEs the superior choice for electrochemical analysis. The developed immunosensor can detect RBD as low as 0.83 fM with long-term storage capacity. The fabricated SPEs immunosensor was tested using a miniaturized portable device and potentiostat on 100 patient nasopharyngeal samples and corroborated with RT-PCR data, displayed 94 % sensitivity. Additionally, the in-house developed polyclonal antibodies detected RBD antigen of the mutated Omicron variant of SARS-CoV-2 successfully. We have not observed any cross-reactivity/binding of the fabricated immunosensor with MERS (cross-reactive antigen) and Influenza A H1N1 (antigen sharing common symptoms). Hence, the developed SPEs sensor may be applied for bedside point-of-care diagnosis of SARS-CoV-2 using miniaturized portable device, in clinical samples.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Técnicas Biossensoriais / Eletrodos / SARS-CoV-2 / COVID-19 / Grafite Limite: Humans Idioma: En Revista: Bioelectrochemistry Assunto da revista: BIOQUIMICA Ano de publicação: 2024 Tipo de documento: Article País de afiliação: Índia País de publicação: Holanda

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Técnicas Biossensoriais / Eletrodos / SARS-CoV-2 / COVID-19 / Grafite Limite: Humans Idioma: En Revista: Bioelectrochemistry Assunto da revista: BIOQUIMICA Ano de publicação: 2024 Tipo de documento: Article País de afiliação: Índia País de publicação: Holanda