Your browser doesn't support javascript.
loading
Factors of mortality in patients with cardiac implantable electronic device: 5-year experience.
Göçer, Kemal; Aykan, Ahmet Çagri; Balcioglu, Akif Serhat; Aksu, Ekrem; Kaniyolu, Murat; Dagli, Musa; Göçer, Naime Sila.
Afiliação
  • Göçer K; Kahramanmaras Sutcu Imam University, Faculty of Medicine, Department of Cardiology - Kahramanmaras, Turkey.
  • Aykan AÇ; Kahramanmaras Sutcu Imam University, Faculty of Medicine, Department of Cardiology - Kahramanmaras, Turkey.
  • Balcioglu AS; Kahramanmaras Sutcu Imam University, Faculty of Medicine, Department of Cardiology - Kahramanmaras, Turkey.
  • Aksu E; Kahramanmaras Sutcu Imam University, Faculty of Medicine, Department of Cardiology - Kahramanmaras, Turkey.
  • Kaniyolu M; Kahramanmaras Sutcu Imam University, Faculty of Medicine, Department of Cardiology - Kahramanmaras, Turkey.
  • Dagli M; Kahramanmaras Sutcu Imam University, Faculty of Medicine, Department of Cardiology - Kahramanmaras, Turkey.
  • Göçer NS; Necip Fazil City Hospital, Department of Infectious Diseases - Kahramanmaras, Turkey.
Rev Assoc Med Bras (1992) ; 70(4): e20230998, 2024.
Article em En | MEDLINE | ID: mdl-38716936
ABSTRACT

OBJECTIVE:

The use of cardiac implantable electronic devices has increased in recent years. It has also brought some issues. Among these, the complications of cardiac implantable electronic devices infection and pocket hematoma are difficult to manage. It can be fatal with the contribution of patient-related risk factors. In this study, we aimed to find mortality rates in patients who developed cardiac implantable electronic devices infection and pocket hematoma over 5 years. We also investigated the risk factors affecting mortality in patients with cardiac implantable electronic devices.

METHODS:

A total of 288 cardiac implantable electronic devices patients were evaluated. Demographic details, history, and clinical data of all patients were recorded. Cardiac implantable electronic devices infection was defined according to the modified Duke criteria. The national registry was used to ascertain the mortality status of the patients. The patients were divided into two groups (exitus and survival groups). In addition, the pocket hematoma was defined as significant bleeding at the pocket site after cardiac implantable electronic devices placement.

RESULTS:

The cardiac implantable electronic devices infection was similar in both groups (p=0.919), and the pocket hematoma was higher in the exitus group (p=0.019). The exitus group had higher usage of P2Y12 inhibitors (p≤0.001) and novel oral anticoagulants (p=0.031). The Cox regression analysis, including mortality-related factors, revealed that renal failure is the most significant risk factor for mortality. Renal failure was linked to a 2.78-fold higher risk of death.

CONCLUSION:

No correlation was observed between cardiac implantable electronic devices infection and mortality, whereas pocket hematoma was associated with mortality. Furthermore, renal failure was the cause of the highest mortality rate in patients with cardiac implantable electronic devices.
Assuntos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Marca-Passo Artificial / Desfibriladores Implantáveis / Hematoma Limite: Aged / Aged80 / Female / Humans / Male / Middle aged Idioma: En Revista: Rev Assoc Med Bras (1992) Ano de publicação: 2024 Tipo de documento: Article País de afiliação: Turquia País de publicação: Brasil

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Marca-Passo Artificial / Desfibriladores Implantáveis / Hematoma Limite: Aged / Aged80 / Female / Humans / Male / Middle aged Idioma: En Revista: Rev Assoc Med Bras (1992) Ano de publicação: 2024 Tipo de documento: Article País de afiliação: Turquia País de publicação: Brasil