Nasopharyngeal airway assistance improves esophageal intubation rates of high-resolution esophageal manometry catheters.
Leopold, Andrew; Wu, Angela; Xie, Guofeng.
Afiliação
  • Leopold A; Division of Gastroenterology & Hepatology, Department of Medicine, University of Maryland School of Medicine, Baltimore, Maryland, USA.
  • Wu A; Department of Internal Medicine, University of Maryland School of Medicine, Baltimore, Maryland, USA.
  • Xie G; Division of Gastroenterology & Hepatology, Department of Medicine, University of Maryland School of Medicine, Baltimore, Maryland, USA.
Neurogastroenterol Motil ; 36(8): e14824, 2024 Aug.
Article em En | MEDLINE | ID: mdl-38775182
ABSTRACT

BACKGROUND:

High-resolution esophageal manometry (HREM) is the gold standard test for esophageal motility disorders. Nasopharyngeal airway-assisted insertion of the HREM catheter is a suggested salvage technique for failure from the inability to pass the catheter through the upper esophageal sphincter (UES). It has not been demonstrated that the nasopharyngeal airway improves procedural success rate.

METHODS:

Patients undergoing HREM between March 2019 and March 2023 were evaluated. Chart review was conducted for patient factors and procedural success rates before and after use of nasopharyngeal airway. Patients from March 2019 to May 2021 did not have nasopharyngeal airway available and were compared to patients from May 2021 to March 2023 who had the nasopharyngeal airway available. KEY

RESULTS:

In total, 523 HREM studies were conducted; 234 occurred prior to nasopharyngeal airway availability, and 289 occurred with nasopharyngeal airway availability. There was no difference in HREM catheter UES intubation rates between periods when a nasopharyngeal airway attempt was considered procedural failure (85% vs. 85%, p = 0.9). Nasopharyngeal airway use after UES intubation failure lead to improved UES intubation rates (94% vs. 85%, p < 0.01). Thirty-six patients that failed HREM catheter UES intubation had the procedure reattempted with a nasopharyngeal airway, 30 (83%) of which were successful. The nasopharyngeal airway assisted catheter UES intubation for failures attributed to nasal pain and hypersensitivity, gagging, coughing, and pharyngeal coiling. CONCLUSIONS & INFERENCES Utilization of the nasopharyngeal airway increased rates of UES intubation. When HREM catheter placement through the UES fails, placement of a nasopharyngeal airway can be trialed to overcome patient procedural intolerance.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Transtornos da Motilidade Esofágica / Manometria Limite: Adult / Aged / Female / Humans / Male / Middle aged Idioma: En Revista: Neurogastroenterol Motil Assunto da revista: GASTROENTEROLOGIA / NEUROLOGIA Ano de publicação: 2024 Tipo de documento: Article País de afiliação: Estados Unidos País de publicação: ENGLAND / ESCOCIA / GB / GREAT BRITAIN / INGLATERRA / REINO UNIDO / SCOTLAND / UK / UNITED KINGDOM

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Transtornos da Motilidade Esofágica / Manometria Limite: Adult / Aged / Female / Humans / Male / Middle aged Idioma: En Revista: Neurogastroenterol Motil Assunto da revista: GASTROENTEROLOGIA / NEUROLOGIA Ano de publicação: 2024 Tipo de documento: Article País de afiliação: Estados Unidos País de publicação: ENGLAND / ESCOCIA / GB / GREAT BRITAIN / INGLATERRA / REINO UNIDO / SCOTLAND / UK / UNITED KINGDOM