Your browser doesn't support javascript.
loading
Ampholytic ion-exchange magnetic beads: a promising tool for selecting short fragments in circulating cell-free DNA analysis.
He, Gan; Wang, Weixuan; Zhou, Yongxia; Zhao, Guowei; Liao, Juan.
Afiliação
  • He G; Gastrointestinal Surgery, Yongchuan Hospital of Chongqing Medical University, Chongqing, China.
  • Wang W; Institute of Life Sciences, Chongqing Medical University, Chongqing, China.
  • Zhou Y; Department of Radiology, Yongchuan Hospital of Chongqing Medical University, Chongqing, China.
  • Zhao G; Center Laboratory, Yongchuan Hospital of Chongqing Medical University, Chongqing, China.
  • Liao J; Gastrointestinal Surgery, Yongchuan Hospital of Chongqing Medical University, Chongqing, China.
Front Oncol ; 14: 1397680, 2024.
Article em En | MEDLINE | ID: mdl-38779084
ABSTRACT

Objective:

For liquid biopsy of cancer, the extraction of circulating cell-free DNA (cfDNA) from plasma is required. We evaluated the efficacy of use of magnetic submicron particles coated with abundant small zwitterions (MSP-ZEWBs) for extracting short fragments of cfDNA.

Methods:

We developed and optimized an MSP-ZEWB-based cfDNA extraction method using ampholytic ion-exchange materials and compared its results with those using a control kit. We measured the cfDNA concentration by quantitative polymerase-chain-reaction and using the Qubit method and analyzed cfDNA fragmentation patterns using a bioanalyzer.

Results:

The fragment size of cfDNA isolated from glycine hydrochloric acid at a pH of 2.2 exhibited a better alignment with the DNA marker. The highest DNA intensity was observed at the final concentration of 0.8% polyethylene glycol 8000. The intensity of cfDNA decreased significantly when isolated from plasma with DNA marker using MSP-ZEWBs with an adsorption buffer containing guanidine hydrochloride or isothiocyanoguanidine. All fragments were successfully extracted using MSP-ZEWBs from both plasma and phosphate-buffered saline. Notably, the intensity of short cfDNA fragments isolated using MSP-ZEWBs remained consistent for recovery of long DNA fragments. indicating a potential selective of small fragments.

Conclusion:

The extraction of plasma cfDNA with MSP-ZEWBs requires no protein denaturation, shows resistance to cells remaining in plasma, and demonstrates higher overall efficiency and better reproducibility than other extraction methods. Use of MSP-ZEWBs may greatly enhance liquid biopsy of cancers through the analysis of plasma cfDNA in clinical practice.
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Revista: Front Oncol Ano de publicação: 2024 Tipo de documento: Article País de afiliação: China País de publicação: Suíça

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Revista: Front Oncol Ano de publicação: 2024 Tipo de documento: Article País de afiliação: China País de publicação: Suíça