Your browser doesn't support javascript.
loading
Modifying carbon dots with L-phenylalanine for rapid discrimination of tryptophan enantiomers.
Lang, Bozhi; Ma, Wenming; Liao, Xuan; Duan, Yaning; Ren, Cuiling; Chen, Hongli.
Afiliação
  • Lang B; State Key Laboratory of Applied Organic Chemistry, College of Chemistry and Chemical Engineering, Lanzhou University, Lanzhou 730000, P. R. China. rencl@lzu.edu.cn.
  • Ma W; State Key Laboratory of Applied Organic Chemistry, College of Chemistry and Chemical Engineering, Lanzhou University, Lanzhou 730000, P. R. China. rencl@lzu.edu.cn.
  • Liao X; State Key Laboratory of Applied Organic Chemistry, College of Chemistry and Chemical Engineering, Lanzhou University, Lanzhou 730000, P. R. China. rencl@lzu.edu.cn.
  • Duan Y; State Key Laboratory of Applied Organic Chemistry, College of Chemistry and Chemical Engineering, Lanzhou University, Lanzhou 730000, P. R. China. rencl@lzu.edu.cn.
  • Ren C; State Key Laboratory of Applied Organic Chemistry, College of Chemistry and Chemical Engineering, Lanzhou University, Lanzhou 730000, P. R. China. rencl@lzu.edu.cn.
  • Chen H; Key Laboratory of Special Function Materials and Structure Design (MOE), Lanzhou University, Lanzhou 730000, China.
Anal Methods ; 16(24): 3907-3916, 2024 Jun 20.
Article em En | MEDLINE | ID: mdl-38829128
ABSTRACT
New chiral carbon dots (CDs), L-PCDs, for discriminating tryptophan (Trp) enantiomers were prepared in this work. Firstly, original CDs were synthesized through a hydrothermal method using pyridine-2,6-dicarboxylic acid and o-phenylenediamine as raw materials. Then, the surface of original CDs was modified with L-phenylalanine to create chiral fluorescent carbon L-PCDs. In the presence of D-Trp, the fluorescence intensity of L-PCDs decreased significantly while it remained unchanged in the presence of L-Trp. The chiral sensing system used in this study has a rapid response time of 3 minutes and can identify enantiomers with an enantioselectivity (ID/IL) of up to 3.3. For D-Trp, a good linear relationship can be obtained in the range of 0.3-4.2 mM with a limit of detection of 0.06 mM. This sensor allows for both quantitative detection of D-Trp and determination of enantiomeric percentage in the racemate. The chiral recognition mechanism is attributed to the different interaction between D-/L-Trp and L-PCDs.

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Revista: Anal Methods Ano de publicação: 2024 Tipo de documento: Article País de publicação: Reino Unido

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Revista: Anal Methods Ano de publicação: 2024 Tipo de documento: Article País de publicação: Reino Unido