Your browser doesn't support javascript.
loading
Silica Nanochannels as Nanoreactors for the Confined Synthesis of Ag NPs to Boost Electrochemical Stripping Chemiluminescence of the Luminol-O2 System for the Sensitive Aptasensor.
Zhou, Xiaoyu; Zou, Yanqi; Ru, Hongjuan; Yan, Fei; Liu, Jiyang.
Afiliação
  • Zhou X; Department of Chemistry, School of Chemistry and Chemical Engineering, Zhejiang Sci-Tech University, Hangzhou 310018, China.
  • Zou Y; Department of Chemistry, School of Chemistry and Chemical Engineering, Zhejiang Sci-Tech University, Hangzhou 310018, China.
  • Ru H; Department of Chemistry, School of Chemistry and Chemical Engineering, Zhejiang Sci-Tech University, Hangzhou 310018, China.
  • Yan F; Key Laboratory of Surface & Interface Science of Polymer Materials of Zhejiang Province, Zhejiang Sci-Tech University, Hangzhou 310018, China.
  • Liu J; Department of Chemistry, School of Chemistry and Chemical Engineering, Zhejiang Sci-Tech University, Hangzhou 310018, China.
Anal Chem ; 96(25): 10264-10273, 2024 06 25.
Article em En | MEDLINE | ID: mdl-38869321
ABSTRACT
Herein, we, for the first time, synthesize silver nanoparticles (Ag NPs) within the nanochannels of amino group-functionalized vertically ordered mesoporous silica films (NH2-VMSF) and investigate their coreaction accelerator role in the luminol-dissolved oxygen (O2) electrochemical stripping chemiluminescence (ESCL) system. The synthesized Ag NPs are capable of electrocatalytic reduction of O2 to superoxide radicals, and meanwhile, sliver ions (Ag+) electrochemically stripped from Ag NPs can promote the amount of luminol anion radicals, generating the boosted ECL intensity of the luminol-dissolved O2 system. This proposed Ag NPs@NH2-VMSF on the indium tin oxide electrode was applied to construct the ESCL aptasensor for quantitative determination of prostate-specific antigen (PSA), yielding a low detection limit [0.19 pg/mL (S/N = 3)] and a broad linear dynamic range (1 pg/mL to 100 ng/mL). Furthermore, good analytical performance of PSA in serum with satisfactory recoveries and low relative standard deviation values is achieved by our developed ESCL aptasensor, rendering it a convenient and sensitive method for PSA determination in clinical applications and further broadening the strategy of ESCL techniques.
Assuntos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Oxigênio / Prata / Dióxido de Silício / Aptâmeros de Nucleotídeos / Nanopartículas Metálicas / Técnicas Eletroquímicas / Medições Luminescentes / Luminol Limite: Humans Idioma: En Revista: Anal Chem Ano de publicação: 2024 Tipo de documento: Article País de afiliação: China País de publicação: EEUU / ESTADOS UNIDOS / ESTADOS UNIDOS DA AMERICA / EUA / UNITED STATES / UNITED STATES OF AMERICA / US / USA

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Oxigênio / Prata / Dióxido de Silício / Aptâmeros de Nucleotídeos / Nanopartículas Metálicas / Técnicas Eletroquímicas / Medições Luminescentes / Luminol Limite: Humans Idioma: En Revista: Anal Chem Ano de publicação: 2024 Tipo de documento: Article País de afiliação: China País de publicação: EEUU / ESTADOS UNIDOS / ESTADOS UNIDOS DA AMERICA / EUA / UNITED STATES / UNITED STATES OF AMERICA / US / USA