Your browser doesn't support javascript.
loading
Optical Sensing of Tissue Freezing Depth by Sapphire Cryo-Applicator and Steady-State Diffuse Reflectance Analysis.
Zotov, Arsen K; Pushkarev, Aleksandr V; Alekseeva, Anna I; Zaytsev, Kirill I; Ryabikin, Sergey S; Tsiganov, Dmitry I; Zhidkov, Dmitriy A; Burkov, Ivan A; Kurlov, Vladimir N; Dolganova, Irina N.
Afiliação
  • Zotov AK; Osipyan Institute of Solid State Physics of the Russian Academy of Sciences, Chernogolovka 142432, Russia.
  • Pushkarev AV; Prokhorov General Physics Institute of the Russian Academy of Sciences, Moscow 119991, Russia.
  • Alekseeva AI; Bauman Moscow State Technical University, Moscow 105005, Russia.
  • Zaytsev KI; Federal State Budgetary Educational Institution of Further Professional Education "Russian Medical Academy of Continuous Professional Education", Ministry of Healthcare of the Russian Federation, Moscow 125993, Russia.
  • Ryabikin SS; Avtsyn Research Institute of Human Morphology, FSBSI "Petrovsky National Research Centre of Surgery", Moscow 117418, Russia.
  • Tsiganov DI; Prokhorov General Physics Institute of the Russian Academy of Sciences, Moscow 119991, Russia.
  • Zhidkov DA; Bauman Moscow State Technical University, Moscow 105005, Russia.
  • Burkov IA; Federal State Budgetary Educational Institution of Further Professional Education "Russian Medical Academy of Continuous Professional Education", Ministry of Healthcare of the Russian Federation, Moscow 125993, Russia.
  • Kurlov VN; Bauman Moscow State Technical University, Moscow 105005, Russia.
  • Dolganova IN; Federal State Budgetary Educational Institution of Further Professional Education "Russian Medical Academy of Continuous Professional Education", Ministry of Healthcare of the Russian Federation, Moscow 125993, Russia.
Sensors (Basel) ; 24(11)2024 Jun 05.
Article em En | MEDLINE | ID: mdl-38894444
ABSTRACT
This work describes a sapphire cryo-applicator with the ability to sense tissue freezing depth during cryosurgery by illumination of tissue and analyzing diffuse optical signals in a steady-state regime. The applicator was manufactured by the crystal growth technique and has several spatially resolved internal channels for accommodating optical fibers. The method of reconstructing freezing depth proposed in this work requires one illumination and two detection channels. The analysis of the detected intensities yields the estimation of the time evolution of the effective attenuation coefficient, which is compared with the theoretically calculated values obtained for a number of combinations of tissue parameters. The experimental test of the proposed applicator and approach for freezing depth reconstruction was performed using gelatin-based tissue phantom and rat liver tissue in vivo. It revealed the ability to estimate depth up to 8 mm. The in vivo study confirmed the feasibility of the applicator to sense the freezing depth of living tissues despite the possible diversity of their optical parameters. The results justify the potential of the described design of a sapphire instrument for cryosurgery.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Imagens de Fantasmas / Criocirurgia / Óxido de Alumínio / Congelamento / Fígado Limite: Animals Idioma: En Revista: Sensors (Basel) Ano de publicação: 2024 Tipo de documento: Article País de afiliação: Federação Russa País de publicação: CH / SUIZA / SUÍÇA / SWITZERLAND

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Imagens de Fantasmas / Criocirurgia / Óxido de Alumínio / Congelamento / Fígado Limite: Animals Idioma: En Revista: Sensors (Basel) Ano de publicação: 2024 Tipo de documento: Article País de afiliação: Federação Russa País de publicação: CH / SUIZA / SUÍÇA / SWITZERLAND