Your browser doesn't support javascript.
loading
Water temperature and energy balance of floating photovoltaic construction water area-field study and modelling.
Liu, Zhao; Ma, Chao; Yang, Yilin; Li, Xinyang; Gou, Haixing; Folkard, Andrew M.
Afiliação
  • Liu Z; State Key Laboratory of Hydraulic Engineering Intelligent Construction and Operation, Tianjin University, Tianjin, 300072, China; School of Civil Engineering, Tianjin University, Tianjin, 300072, China.
  • Ma C; State Key Laboratory of Hydraulic Engineering Intelligent Construction and Operation, Tianjin University, Tianjin, 300072, China; School of Civil Engineering, Tianjin University, Tianjin, 300072, China; School of Civil and Traffic Engineering, Qinghai Minzu University, Qinghai, 810007, China. Electr
  • Yang Y; Tianjin Key Laboratory of Water Resources and Environment, Tianjin Normal University, Tianjin, 300387, China.
  • Li X; State Key Laboratory of Hydraulic Engineering Intelligent Construction and Operation, Tianjin University, Tianjin, 300072, China; School of Civil Engineering, Tianjin University, Tianjin, 300072, China.
  • Gou H; State Key Laboratory of Hydraulic Engineering Intelligent Construction and Operation, Tianjin University, Tianjin, 300072, China; School of Civil Engineering, Tianjin University, Tianjin, 300072, China.
  • Folkard AM; Lancaster Environment Centre, Library Avenue, Lancaster University, Lancaster, LA1 4YQ, United Kingdom.
J Environ Manage ; 365: 121494, 2024 Aug.
Article em En | MEDLINE | ID: mdl-38897079
ABSTRACT
Floating photovoltaics (FPV) are an emerging renewable energy technology. Although they have received extensive attention in recent years, understanding of their environmental impacts is limited. To address this knowledge gap, we measured water temperature and meteorological parameters for six months under FPV arrays and in the control open water site and constructed a numerical model reflecting the water energy balance. Our results showed that FPV arrays caused diurnal variation in water temperature and microclimate. Specifically, we found that FPV had a cooling effect on their host waterbody during the daytime and a heat preservation effect at night, reducing diurnal variation. The diel oscillation of water temperature below FPV panels lagged behind that of open waters by approximately two hours. The microclimate conditions below FPV panels also changed, with wind speed decreasing by 70%, air temperature increasing during the daytime (averaging +2.01°C) and decreasing at night (averaging -1.27°C). Notably, the trend in relative humidity was the opposite (-3.72%, +14.43%). Correlation analysis showed that the degree of water temperature affected by FPV was related to local climate conditions. The numerical model could capture the energy balance characteristics with a correlation coefficient of 0.80 between the simulated and actual data. The shortwave radiation and latent heat flux below FPV panels was significantly reduced, and the longwave radiation emitted by FPV panels became one of the heat sources during the daytime. The combined variations of these factors dominated the water energy balance below FPV panels. The measured data and simulation results serve as a foundation for evaluating the impact of FPV systems on water temperature, energy budget, and aquatic environment, which would also provide a more comprehensive understanding of FPV systems.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Temperatura / Água Idioma: En Revista: J Environ Manage Ano de publicação: 2024 Tipo de documento: Article País de afiliação: China País de publicação: Reino Unido

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Temperatura / Água Idioma: En Revista: J Environ Manage Ano de publicação: 2024 Tipo de documento: Article País de afiliação: China País de publicação: Reino Unido