Your browser doesn't support javascript.
loading
Green method by National Environmental Methods Index and Eco-Scale Assessment for evaluation of gatifloxacin-based product by HPLC.
Dos Santos Galvão, Natália Sabina; de Oliveira, Naiara Raica Lopes; de Oliveira Neto, Jerônimo Raimundo; Kogawa, Ana Carolina.
Afiliação
  • Dos Santos Galvão NS; Laboratório de Controle de Qualidade, Faculty of Pharmacy, Federal University of Goiás, Goiânia, Goiás, Brazil.
  • de Oliveira NRL; Laboratório Multiusuário de Análises Químicas e Biológicas para Desenvolvimento e Inovação, Faculty of Pharmacy, Federal University of Goiás, Goiânia, Goiás, Brazil.
  • de Oliveira Neto JR; Núcleo de Estudos e Pesquisas Tóxico-Farmacológicas, Faculty of Pharmacy, Federal University of Goiás, Goiânia, Goiás, Brazil.
  • Kogawa AC; Laboratório de Controle de Qualidade, Faculty of Pharmacy, Federal University of Goiás, Goiânia, Goiás, Brazil.
Biomed Chromatogr ; 38(8): e5928, 2024 Aug.
Article em En | MEDLINE | ID: mdl-38924173
ABSTRACT
The literature reveals gaps in the availability of green analytical methods for assessing products containing gatifloxacin (GFX), a fluoroquinolone. Presently, method development is supported by tools such as the National Environmental Methods Index (NEMI) and Eco-Scale Assessment (ESA), which offer objective insights into the environmental friendliness of analytical procedures. The objective of this work was to develop and validate a green method by the NEMI and ESA to quantify GFX in eye drops using HPLC. The method utilized a C8 column (4.6 × 150 mm, 5 µm), with a mobile phase of purified water containing 2% acetic acid and ethanol (7030, v/v). The injection volume was 10 µL and the flow rate was 0.7 mL/min in isocratic mode at 25°C, with detection performed at 292 nm. The method demonstrated linearity in the range of 2-20 µg/mL, and precision at intra-day (relative standard deviation [RSD] 1.44%), inter-day (RSD 3.45%), and inter-analyst (RSD 2.04%) levels. It was selective regarding the adjuvants of the final product (eye drops) and under forced degradation conditions. The method was accurate (recovery 101.07%) and robust. The retention time for GFX was approximately 3.5 min. The greenness of the method, as evaluated by the NEMI, showed four green quadrants, and by ESA, it achieved a score of 88.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Soluções Oftálmicas / Química Verde / Limite de Detecção / Gatifloxacina Idioma: En Revista: Biomed Chromatogr Ano de publicação: 2024 Tipo de documento: Article País de afiliação: Brasil País de publicação: ENGLAND / ESCOCIA / GB / GREAT BRITAIN / INGLATERRA / REINO UNIDO / SCOTLAND / UK / UNITED KINGDOM

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Soluções Oftálmicas / Química Verde / Limite de Detecção / Gatifloxacina Idioma: En Revista: Biomed Chromatogr Ano de publicação: 2024 Tipo de documento: Article País de afiliação: Brasil País de publicação: ENGLAND / ESCOCIA / GB / GREAT BRITAIN / INGLATERRA / REINO UNIDO / SCOTLAND / UK / UNITED KINGDOM