Your browser doesn't support javascript.
loading
A directional total variation minimization algorithm for isotropic resolution in digital breast tomosynthesis.
Sidky, Emil Y; Wu, Xiangyi; Duan, Xiaoyu; Huang, Hailing; Zhao, Wei; Zhang, Leo Y; Phillips, John Paul; Zhang, Zheng; Chen, Buxin; Xia, Dan; Reiser, Ingrid S; Pan, Xiaochuan.
Afiliação
  • Sidky EY; Department of Radiology MC-2026, The University of Chicago, 5841. S. Maryland Ave., Chicago, IL, 60637.
  • Wu X; Department of Radiology, Renaissance School of Medicine, Stony Brook University, 101 Nicolls Road, Health Sciences Center, Level 4, Stony Brook, NY, 11794.
  • Duan X; Department of Radiology, Renaissance School of Medicine, Stony Brook University, 101 Nicolls Road, Health Sciences Center, Level 4, Stony Brook, NY, 11794.
  • Huang H; Department of Radiology, Renaissance School of Medicine, Stony Brook University, 101 Nicolls Road, Health Sciences Center, Level 4, Stony Brook, NY, 11794.
  • Zhao W; Department of Radiology, Renaissance School of Medicine, Stony Brook University, 101 Nicolls Road, Health Sciences Center, Level 4, Stony Brook, NY, 11794.
  • Zhang LY; Department of Mathematics, University of Washington, Box 354350, C-138 Padelford, Seattle, WA 98195-4350.
  • Phillips JP; Department of Radiology MC-2026, The University of Chicago, 5841. S. Maryland Ave., Chicago, IL, 60637.
  • Zhang Z; Department of Radiology MC-2026, The University of Chicago, 5841. S. Maryland Ave., Chicago, IL, 60637.
  • Chen B; Department of Radiology MC-2026, The University of Chicago, 5841. S. Maryland Ave., Chicago, IL, 60637.
  • Xia D; Department of Radiology MC-2026, The University of Chicago, 5841. S. Maryland Ave., Chicago, IL, 60637.
  • Reiser IS; Department of Radiology MC-2026, The University of Chicago, 5841. S. Maryland Ave., Chicago, IL, 60637.
  • Pan X; Department of Radiology MC-2026, The University of Chicago, 5841. S. Maryland Ave., Chicago, IL, 60637.
ArXiv ; 2024 Jun 11.
Article em En | MEDLINE | ID: mdl-38947918
ABSTRACT
An optimization-based image reconstruction algorithm is developed for contrast enhanced digital breast tomosynthesis (DBT) using dual-energy scanning. The algorithm minimizes directional total variation (TV) with a data discrepancy and non-negativity constraints. Iodinated contrast agent (ICA) imaging is performed by reconstructing images from dual-energy DBT data followed by weighted subtraction. Physical DBT data is acquired with a Siemens Mammomat scanner of a structured breast phantom with ICA inserts. Results are shown for both directional TV minimization and filtered back-projection for reference. It is seen that directional TV is able to substantially reduce depth blur for the ICA objects.
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Revista: ArXiv Ano de publicação: 2024 Tipo de documento: Article País de publicação: EEUU / ESTADOS UNIDOS / ESTADOS UNIDOS DA AMERICA / EUA / UNITED STATES / UNITED STATES OF AMERICA / US / USA

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Revista: ArXiv Ano de publicação: 2024 Tipo de documento: Article País de publicação: EEUU / ESTADOS UNIDOS / ESTADOS UNIDOS DA AMERICA / EUA / UNITED STATES / UNITED STATES OF AMERICA / US / USA