Your browser doesn't support javascript.
loading
A universal fluorescence biosensor based on rolling circle amplification and locking probe for DNA detection.
Fang, Ying; Nie, Lanxin; Wang, Suqin; Liu, Shiwen; Li, Hongbo; Yu, Ruqin.
Afiliação
  • Fang Y; College of Chemistry and Chemical Engineering, Jiangxi Normal University, Nanchang, 330022, P.R. China.
  • Nie L; College of Chemistry and Chemical Engineering, Jiangxi Normal University, Nanchang, 330022, P.R. China.
  • Wang S; College of Chemistry and Chemical Engineering, Jiangxi Normal University, Nanchang, 330022, P.R. China.
  • Liu S; College of Chemistry and Chemical Engineering, Jiangxi Normal University, Nanchang, 330022, P.R. China. liushiwen985@126.com.
  • Li H; Jiangxi Provincial Center for Disease Control and Prevention, Nanchang, 330029, P. R. China. liushiwen985@126.com.
  • Yu R; College of Chemistry and Chemical Engineering, Jiangxi Normal University, Nanchang, 330022, P.R. China. lihongbo112@126.com.
Mikrochim Acta ; 191(7): 437, 2024 07 01.
Article em En | MEDLINE | ID: mdl-38951284
ABSTRACT
A stable DNA signal amplification sensor was developed on account of rolling circle amplification (RCA). This sensor includes target DNA-controlled rolling circle amplification technology and locking probe DNA replacement technology, which can be used to detect DNA fragments with genetic information, thus constructing a biosensor for universal detection of DNA. This study takes the homologous DNA of human immunodeficiency virus (HIV) and let-7a as examples to describe this biosensor. The padlock probe is first cyclized by T4 DNA ligase in response to the target's reaction with it. Then, rolling cycle amplification is initiated by Phi29 DNA polymerase, resulting in the formation of a lengthy chain with several triggers. These triggers can open the locked probe LP1 with the fluorescence signal turned off, so that it can continue to react with H2 to form a stable H1-H2 double strand. This regulates the distance between B-DNA modified by the quenching group and H1 modified by fluorescent group, and the fluorescence signal is recovered.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Técnicas Biossensoriais / Sondas de DNA / Técnicas de Amplificação de Ácido Nucleico Limite: Humans Idioma: En Revista: Mikrochim Acta Ano de publicação: 2024 Tipo de documento: Article País de publicação: AT / AUSTRIA / ÁUSTRIA

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Técnicas Biossensoriais / Sondas de DNA / Técnicas de Amplificação de Ácido Nucleico Limite: Humans Idioma: En Revista: Mikrochim Acta Ano de publicação: 2024 Tipo de documento: Article País de publicação: AT / AUSTRIA / ÁUSTRIA