Ultrasound-guided methylene blue dyeing liver segmental resection for hepatocellular carcinoma / 中华普通外科杂志
Chinese Journal of General Surgery
; (12): 844-846, 2015.
Article
em Zh
| WPRIM
| ID: wpr-483203
Biblioteca responsável:
WPRO
ABSTRACT
Objective To evaluate ultrasound-guided methylene blue dyeing for radical liver segmental resection.Methods Liver segmental resection with uhrasound-guide methylene blue dyeing (UMD-SR) was performed in 16 cases, results were compared with 16 conventional liver segmental resection (CSR) retrospectively.Results All the operations under uhrasound-guided methylene blue dyeing were successfully carried out, among them, reverse dyeing was used in cases with segment Ⅳ, Ⅴ, Ⅷ resection.The blood loss in UMD-SR group was much less than CSR group(t =3.011 ,P =0.009) , at the cost of a longer operation time (t =5.423,P =0.000 07).There was no difference in the mortality and morbidity rates between two groups.Tumor recurrence rate was 6.25% in UMD-SR group and 18.75% in CSR group (x2 =0.133,P =0.285).Conclusions Ultrasound-guided methylene blue dyeing liver segmental resection can reduce the blood loss during operation, improve the safety of hepatectomy in case of hepatic carcinoma.
Texto completo:
1
Base de dados:
WPRIM
Idioma:
Zh
Revista:
Chinese Journal of General Surgery
Ano de publicação:
2015
Tipo de documento:
Article