Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
1.
Arq. bras. cardiol ; 111(4): 607-615, Oct. 2018. tab, graf
Artigo em Inglês | LILACS | ID: biblio-973766

RESUMO

Abstract Background: Heart failure (HF) affects more than 5 million individuals in the United States, with more than 1 million hospital admissions per year. Cardiac resynchronization therapy (CRT) can benefit patients with advanced HF and prolonged QRS. A significant percentage of patients, however, does not respond to CRT. Electrical dyssynchrony isolated might not be a good predictor of response, and the last left ventricular (LV) segment to contract can influence the response. Objectives: To assess electromechanical dyssynchrony in CRT with LV lead implantation guided by GATED SPECT. Methods: This study included 15 patients with functional class II-IV HF and clinically optimized, ejection fraction of 35%, sinus rhythm, left bundle-branch block, and QRS ≥ 120 ms. The patients underwent electrocardiography, answered the Minnesota Living with Heart Failure Questionnaire (MLHFQ), and underwent gated myocardial perfusion SPECT up to 4 weeks before CRT, being reassessed 6 months later. The primary analysis aimed at determining the proportion of patients with a reduction in QRS duration and favorable response to CRT, depending on concordance of the LV lead position, using chi-square test. The pre- and post-CRT variables were analyzed by use of Student t test, adopting the significance level of 5%. Results: We implanted 15 CRT devices, and 2 patients died during follow-up. The durations of the QRS (212 ms vs 136 ms) and the PR interval (179 ms vs 126 ms) were significantly reduced (p < 0.001). In 54% of the patients, the lead position was concordant with the maximal delay site. In the responder group, the lateral position was prevalent. The MLHFQ showed a significant improvement in quality of life (p < 0.0002). Conclusion: CRT determines improvement in the quality of life and in electrical synchronism. Electromechanical synchronism relates to response to CRT. Positioning the LV lead in the maximal delay site has limitations.


Resumo Fundamento: A insuficiência cardíaca (IC) afeta mais de 5 milhões de pessoas nos Estados Unidos, com mais de 1 milhão de internações/ano. A terapia de ressincronização (TRC) pode beneficiar pacientes com IC avançada e QRS alargado; entretanto, percentual significativo de pacientes não respondem à TRC. O dissincronismo elétrico isolado pode não representar um bom preditor de resposta, e o local da última ativação do ventrículo esquerdo (VE) pode influenciar na resposta. Objetivos: Avaliar o dissincronismo eletromecânico na TRC com o implante do eletrodo do VE orientado por GATED SPECT. Métodos: Incluídos 15 pacientes com IC classe funcional II-IV, otimizados clinicamente, com fração de ejeção de 35%, ritmo sinusal, bloqueio de ramo esquerdo, QRS ≥ 120 ms. Realizaram eletrocardiograma, Questionário Minnesota Vivendo com Insuficiência Cardíaca (MLHFQ) e cintilografia GATED SPECT até 4 semanas antes do implante. Reavaliados 6 meses após. Análise primária visou determinar a proporção de pacientes com redução da duração do QRS e resposta favorável à TRC dependendo da concordância ou não na posição do eletrodo, utilizando teste Qui-Quadrado. Análise das variáveis pré e pós TRC foi feita através do teste t de Student, assumindo significância de 5%. Resultados: Realizamos 15 implantes com 2 óbitos no seguimento. As reduções das durações do QRS (212 ms vs 136 ms) e do IPR (179 ms vs 126 ms) foram significativas (p < 0,001). Em 54%, o eletrodo foi concordante com o local de maior atraso. No grupo respondedor, a posição lateral foi prevalente. O MLHFQ mostrou melhora significativa da qualidade de vida (p < 0,0002). Conclusão: A TRC determina melhora da qualidade de vida e do sincronismo elétrico. O sincronismo eletromecânico relaciona-se com a resposta à TRC. O posicionamento do eletrodo de VE no sítio de maior retardo tem limitações.


Assuntos
Humanos , Masculino , Feminino , Pessoa de Meia-Idade , Idoso , Disfunção Ventricular Esquerda/terapia , Tomografia Computadorizada por Emissão de Fóton Único de Sincronização Cardíaca/métodos , Terapia de Ressincronização Cardíaca/métodos , Dispositivos de Terapia de Ressincronização Cardíaca , Insuficiência Cardíaca/terapia , Qualidade de Vida , Volume Sistólico , Fatores de Tempo , Bloqueio de Ramo/fisiopatologia , Bloqueio de Ramo/terapia , Fluoroscopia , Resultado do Tratamento , Disfunção Ventricular Esquerda/fisiopatologia , Disfunção Ventricular Esquerda/diagnóstico por imagem , Estatísticas não Paramétricas , Eletrocardiografia , Insuficiência Cardíaca/fisiopatologia , Insuficiência Cardíaca/diagnóstico por imagem
2.
Arq. bras. cardiol ; 107(5): 455-459, Nov. 2016. tab, graf
Artigo em Inglês | LILACS | ID: biblio-827874

RESUMO

Abstract Background: In the Systolic Heart Failure Treatment With the If Inhibitor Ivabradine Trial (SHIFT), heart rate (HR) reduction with ivabradine was associated with improved survival and reduced hospitalizations in patients with heart failure (HF). The mechanisms by which elevated HR increases mortality are not fully understood. Objective: To assess the relationship of baseline HR with clinical, neurohormonal and cardiac sympathetic activity in patients with chronic HF and elevated HR. Method: Patients with chronic HF who were in sinus rhythm and had resting HR>70 bpm despite optimal medical treatment were included in a randomized, double-blind study comparing ivabradine versus pyridostigmine. This report refers to the baseline data of 16 initial patients. Baseline HR (before randomization to one of the drugs) was assessed, and patients were classified into two groups, with HR below or above mean values. Cardiac sympathetic activity was assessed by 123-iodine-metaiodobenzylguanidine myocardial scintigraphy. Results: Mean HR was 83.5±11.5 bpm (range 72 to 104), and seven (43.7%) patients had HR above the mean. These patients had lower 6-min walk distance (292.3±93 vs 465.2±97.1 m, p=0.0029), higher values of N-Terminal-proBNP (median 708.4 vs 76.1, p=0.035) and lower late heart/mediastinum rate, indicating cardiac denervation (1.48±0.12 vs 1.74±0.09, p<0.001). Conclusion: Elevated resting HR in patients with HF under optimal medical treatment was associated with cardiac denervation, worse functional capacity, and neurohormonal activation.


Resumo Fundamento: No SHIFT (Systolic Heart Failure Treatment With the If Inhibitor Ivabradine Trial, ou Estudo do Tratamento da Insuficiência Cardíaca Sistólica com o Inibidor de If Ivabradina), a redução da frequência cardíaca (FC) com ivabradina associou-se com melhor sobrevida e redução das hospitalizações em pacientes com insuficiência cardíaca (IC). Os mecanismos pelos quais a FC elevada aumenta a mortalidade não são totalmente compreendidos. Objetivo: Avaliar a relação da FC basal com atividade clínica, neuro-hormonal e simpática cardíaca em pacientes com IC crônica e FC elevada. Método: Pacientes com IC crônica em ritmo sinusal e FC≥70 apesar de tratamento adequado foram incluídos em um estudo duplo-cego, randomizado, que comparou ivabradina com piridostigmina. Este artigo refere-se a dados basais dos primeiros 16 pacientes. A FC basal (antes da randomização para um dos medicamentos) foi avaliada, e os pacientes classificados em dois grupos, com FC abaixo ou acima dos valores médios. A atividade simpática cardíaca foi avaliada por cintilografia com metaiodobenzilguanidina marcada com iodo 123. Resultados: A FC média foi 83,5±11,5 bpm (intervalo 72 a 104), e sete pacientes (43.7%) tinham FC acima da média. Esses pacientes apresentaram menor distância percorrida no teste de caminhada de 6 minutos (292,3±93 vs 465,2±97,1 m, p=0,0029), valores mais altos de N-terminal do pró-BNP (mediana 708,4 vs 76,1, p=0,035) e menor relação coração/mediastino tardia, indicando desnervação cardíaca (1,48±0,12 vs 1,74±0,09, p<0,001). Conclusão: A FC de repouso elevada em pacientes com IC em tratamento médico adequado associou-se com desnervação cardíaca, pior capacidade funcional e ativação neuro-hormonal.


Assuntos
Humanos , Masculino , Feminino , Adulto , Pessoa de Meia-Idade , Sistema Nervoso Simpático/diagnóstico por imagem , 3-Iodobenzilguanidina , Coração/inervação , Insuficiência Cardíaca/diagnóstico por imagem , Frequência Cardíaca/fisiologia , Sistema Nervoso Simpático/fisiologia , Fármacos Cardiovasculares/uso terapêutico , Cintilografia , Doença Crônica , Denervação , Teste de Esforço , Coração/diagnóstico por imagem , Insuficiência Cardíaca/tratamento farmacológico
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA