Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros







Base de dados
Intervalo de ano de publicação
1.
J. bras. pneumol ; 46(1): e20180397, 2020. tab, graf
Artigo em Inglês | LILACS | ID: biblio-1056621

RESUMO

ABSTRACT Objective: To test the construct validity, reliability, and measurement error of the Brazilian Portuguese-language version of the Manchester Respiratory Activities of Daily Living (MRADL) questionnaire in patients with COPD. Methods: We evaluated 50 patients with COPD, among whom 30 were men, the mean age was 64 ± 8 years, and the median FEV1 as a percentage of the predicted value (FEV1%predicted) was 38.4% (interquartile range, 29.1-57.4%). Pulmonary function and limitations in activities of daily living (ADLs) were assessed by spirometry and by face-to-face application of the MRADL, respectively. For the construct validity analysis, we tested the hypothesis that the total MRADL score would show moderate correlations with spirometric parameters. We analyzed inter-rater reliability, test-retest reliability, inter-rater measurement error, and test-retest measurement error. Results: The total MRADL score showed moderate correlations with the FEV1/FVC ratio, FEV1 in liters, FEV1%predicted, and FVC%predicted, all of the correlations being statistically significant (r = 0.34, r = 0.31, r = 0.42, and r = 0.38, respectively; p < 0.05 for all). For the reliability and measurement error of the total MRADL score, we obtained the following inter-rater and test-retest values, respectively: two-way mixed-effects model intraclass correlation coefficient for single measures, 0.92 (95% CI: 0.87-0.96) and 0.89 (95% CI: 0.81-0.93); agreement standard error of measurement, 1.03 and 0.97; smallest detectable change at the individual level, 2.86 and 2.69; smallest detectable change at the group level, 0.40 and 0.38; and limits of agreement, −2.24 to 1.96 and −2.65 to 2.69. Conclusions: In patients with COPD in Brazil, this version of the MRADL shows satisfactory construct validity, satisfactory inter-rater/test-retest reliability, and indeterminate inter-rater/test-retest measurement error.


RESUMO Objetivo: Testar a validade de construto, a confiabilidade e o erro de medida da versão em português do Brasil do questionário Manchester Respiratory Activities of Daily Living (MRADL) em pacientes com DPOC. Métodos: Avaliamos 50 pacientes com DPOC, 30 dos quais eram homens. A média de idade foi de 64 ± 8 anos, e a mediana do VEF1 em porcentagem do previsto (VEF1%previsto) foi de 38,4% (intervalo interquartil: 29,1-57,4%). A função pulmonar e limitações experimentadas durante a realização de atividades cotidianas foram avaliadas por meio de espirometria e da aplicação presencial do MRADL, respectivamente. Para a análise de validade de construto, testamos a hipótese de que haveria correlações moderadas entre a pontuação total no MRADL e parâmetros espirométricos. Analisamos a confiabilidade e o erro de medida entre avaliadores e entre teste e reteste. Resultados: Houve correlações moderadas e estatisticamente significativas entre a pontuação total no MRADL e VEF1/CVF, VEF1 em litros, VEF1%previsto e CVF%previsto (r = 0,34, r = 0,31, r = 0,42 e r = 0,38, respectivamente; p < 0,05 para todas). No tocante à confiabilidade e ao erro de medida para a pontuação total no MRADL entre avaliadores e entre teste e reteste, respectivamente, foram obtidos os seguintes valores: coeficiente de correlação intraclasse de duas vias e efeitos mistos para medidas únicas = 0,92 (IC95%: 0,87-0,96) e 0,89 (IC95%: 0,81-0,93); erro-padrão de medida do tipo concordância = 1,03 e 0,97; mínima mudança detectável no indivíduo = 2,86 e 2,69; mínima mudança detectável no grupo = 0,40 e 0,38; limites de concordância = −2,24 a 1,96 e −2,65 a 2,69. Conclusões: Em pacientes com DPOC, a versão brasileira do MRADL apresenta validade de construto satisfatória, confiabilidade interavaliadores/teste-reteste satisfatória e erro de medida interavaliadores/teste-reteste indeterminado.


Assuntos
Humanos , Masculino , Pessoa de Meia-Idade , Idoso , Atividades Cotidianas , Inquéritos e Questionários , Doença Pulmonar Obstrutiva Crônica/fisiopatologia , Tradução , Índice de Gravidade de Doença , Reprodutibilidade dos Testes , Características Culturais
2.
J. bras. pneumol ; 44(5): 370-377, Sept.-Oct. 2018. tab, graf
Artigo em Inglês | LILACS | ID: biblio-975935

RESUMO

ABSTRACT Objective: To develop reference equations for the Glittre Activities of Daily Living test (Glittre ADL-test) on the basis of anthropometric and demographic variables in apparently healthy individuals. A secondary objective was to determine the reliability of the equations in a sample of COPD patients. Methods: This was a cross-sectional study including 190 apparently healthy individuals (95 males; median age, 54.5 years [range, 42-65]; median FEV1 = 97% [range, 91-105.2]; and median FVC = 96% [range, 88.5-102]) recruited from the general community and 74 COPD patients (55 males; mean age, 65 ± 8 years; body mass index [BMI] = 25.9 ± 4.7 kg/m2; FEV1 = 36.1 ± 14.1%; and FVC = 62.7 ± 16.1%) recruited from a pulmonary rehabilitation center. Results: The mean time to complete the Glittre ADL-test was 2.84 ± 0.45 min. In the stepwise multiple linear regression analysis, age and height were selected as Glittre ADL-test performance predictors, explaining 32.1% (p < 0.01) of the total variance. Equation 1 was as follows: Glittre ADL-testpredicted = 3.049 + (0.015 × ageyears) + (−0.006 × heightcm). Equation 2 included age and BMI and explained 32.3% of the variance in the test, the equation being as follows: Glittre ADL-testpredicted = 1.558 + (0.018 × BMI) + (0.016 × ageyears). Conclusions: The reference equations for the time to complete the Glittre ADL-test were based on age, BMI, and height as independent variables and can be useful for predicting the performance of adult individuals. The predicted values appear to be reliable when applied to COPD patients.


RESUMO Objetivo: Elaborar equações de referência para o teste Glittre Activities of Daily Living (Glittre ADL) com base em variáveis antropométricas e demográficas em indivíduos aparentemente saudáveis. O objetivo secundário foi determinar a confiabilidade das equações em uma amostra composta por pacientes com DPOC. Métodos: Estudo transversal com 190 indivíduos aparentemente saudáveis [95 homens; mediana de idade: 54,5 anos (variação: 42-65); mediana de VEF1 = 97% (variação: 91-105,2); mediana de CVF = 96% (variação: 88,5-102)] recrutados na comunidade geral e 74 pacientes com DPOC [55 homens; média de idade: 65 ± 8 anos; índice de massa corporal (IMC) = 25,9 ± 4,7 kg/m2; VEF1 = 36,1 ± 14,1%; CVF = 62,7 ± 16,1%] recrutados em um centro de reabilitação pulmonar. Resultados: A média do tempo necessário para completar o teste Glittre ADL foi de 2,84 ± 0,45 min. Na análise de regressão linear múltipla passo a passo (stepwise), a idade e a estatura foram selecionadas como preditores do desempenho no teste Glittre ADL, explicando 32,1% (p < 0,01) da variância total. A equação 1 foi a seguinte: Glittre ADLprevisto = 3,049 + (0,015 × idadeanos) + (−0,006 × alturacm). A equação 2 incluiu idade e IMC e explicou 32,3% da variância do teste: Glittre ADLprevisto = 1,558 + (0,018 × IMC) + (0,016 × idadeanos). Conclusões: As equações de referência para o tempo necessário para completar o teste Glittre ADL basearam-se na idade, IMC e estatura como variáveis independentes e podem ser úteis para prever o desempenho de indivíduos adultos. Os valores previstos são aparentemente confiáveis quando aplicados em pacientes com DPOC.


Assuntos
Humanos , Masculino , Feminino , Adulto , Pessoa de Meia-Idade , Idoso , Idoso de 80 Anos ou mais , Qualidade de Vida , Atividades Cotidianas , Doença Pulmonar Obstrutiva Crônica/fisiopatologia , Teste de Esforço , Padrões de Referência , Estudos Transversais , Reprodutibilidade dos Testes
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA