Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
Mais filtros







Base de dados
Intervalo de ano de publicação
1.
Arq. bras. cardiol ; 109(6): 550-559, Dec. 2017. tab, graf
Artigo em Inglês | LILACS, SES-SP, SESSP-IDPCPROD, SES-SP | ID: biblio-887985

RESUMO

Abstract Background: Transcatheter aortic valve implantation (TAVI) is a well-established procedure; however, atrioventricular block requiring permanent pacemaker implantation (PPI) is a common complication. Objectives: To determine the incidence, predictors and clinical outcomes of PPI after TAVI, focusing on how PPI affects left ventricular ejection fraction (LVEF) after TAVI. Methods: The Brazilian Multicenter TAVI Registry included 819 patients submitted to TAVI due to severe aortic stenosis from 22 centers from January/2008 to January/2015. After exclusions, the predictors of PPI were assessed in 670 patients by use of multivariate regression. Analysis of the ROC curve was used to measure the ability of the predictors; p < 0.05 was the significance level adopted. Results: Within 30 days from TAVI, 135 patients (20.1%) required PPI. Those patients were older (82.5 vs. 81.1 years; p = 0.047) and mainly of the male sex (59.3% vs 45%; p = 0.003). Hospital length of stay was longer in patients submitted to PPI (mean = 15.7 ± 25.7 vs. 11.8 ± 22.9 days; p < 0.001), but PPI affected neither all-cause death (26.7% vs. 25.6%; p = 0.80) nor cardiovascular death (14.1% vs. 14.8%; p = 0.84). By use of multivariate analysis, the previous presence of right bundle-branch block (RBBB) (OR, 6.19; 3.56-10.75; p ≤ 0.001), the use of CoreValve® prosthesis (OR, 3.16; 1.74-5.72; p ≤ 0.001) and baseline transaortic gradient > 50 mm Hg (OR, 1.86; 1.08-3.2; p = 0.025) were predictors of PPI. The estimated risk of PPI ranged from 4%, when none of those predictors was present, to 63%, in the presence of all of them. The model showed good ability to predict the need for PPI: 0.69 (95%CI: 0.64 - 0.74) in the ROC curve. The substudy of 287 echocardiograms during the 1-year follow-up showed worse LVEF course in patients submitted to PPI (p = 0.01). Conclusion: BRD prévio, gradiente aórtico médio > 50 mmHg e CoreValve® são preditores independentes de implante de MPD pós-TAVI. Ocorreu implante de MPD em aproximadamente 20% dos casos de TAVI, o que prolongou a internação hospitalar, mas não afetou a mortalidade. O implante de MPD afetou negativamente a FEVE pós-TAVI.


Resumo Fundamento: O implante valvar aórtico transcateter (TAVI) está bem estabelecido, porém, o bloqueio atrioventricular, com necessidade de marca-passo definitivo (MPD), é complicação frequente. Objetivo: Determinar a incidência, preditores e desfechos clínicos de implante de MPD após TAVI, focando em como a evolução da fração de ejeção do ventrículo esquerdo (FEVE), após o TAVI, é afetada pelo MPD. Métodos: No registro brasileiro foram incluídos 819 pacientes submetidos a TAVI por estenose aórtica severa em 22 centros entre janeiro/2008 e janeiro/2015. Após exclusões, os preditores de implante de MPD foram avaliados em 670 pacientes por regressão multivariada. Análise da curva ROC foi utilizada para medir a habilidade dos preditores; p < 0,05 foi considerado significativo. Resultados: Aos 30 dias, 135 pacientes (20,1%) necessitaram de MPD. Tais pacientes eram mais velhos (82,5 vs. 81,1 anos; p = 0,047) e predominantemente homens (59,3% vs 45%; p = 0,003). A permanência hospitalar foi maior no Grupo MPD (média= 15,7 ± 25,7 vs. 11,8 ± 22,9 dias; p < 0,001), mas o implante não afetou morte por qualquer causa (26,7% vs. 25,6%; p = 0,80) nem morte cardiovascular (14,1% vs. 14,8%; p = 0,84). Por análise multivariada, a presença prévia de bloqueio de ramo direito (BRD) (OR, 6,19; 3,56-10,75; p ≤ 0,001), o uso da prótese CoreValve® (OR, 3,16; 1,74-5,72; p ≤ 0,001) e gradiente transaórtico basal > 50 mmHg (OR, 1,86; 1,08-3,2; p= 0,025) foram preditores de implante de MPD. O risco estimado de implante de MPD foi 4%, quando nenhum dos fatores de risco estava presente, e 63% na presença de todos. O modelo mostrou boa habilidade de prever a necessidade de MPD: 0,69 (IC95%: 0,64 - 0,74) na curva ROC. Subestudo de 287 ecocardiogramas durante o seguimento de 1 ano mostrou pior evolução da FEVE no Grupo MPD (p = 0,01). Conclusão: Em crianças de 6 a 11 anos, circunferência da cintura aumentada está associada à PA elevada, mesmo quando o IMC é normal. (Arq Bras Cardiol. 2017; [online].ahead print, PP.0-0)


Assuntos
Humanos , Masculino , Feminino , Idoso de 80 Anos ou mais , Valva Aórtica/cirurgia , Marca-Passo Artificial/efeitos adversos , Bloqueio de Ramo/cirurgia , Próteses Valvulares Cardíacas/efeitos adversos , Estimulação Cardíaca Artificial/métodos , Implante de Prótese de Valva Cardíaca/efeitos adversos , Bloqueio Atrioventricular/cirurgia , Estenose da Valva Aórtica/cirurgia , Complicações Pós-Operatórias , Brasil , Fatores de Risco , Eletrocardiografia , Bloqueio Atrioventricular/fisiopatologia
2.
Arq. bras. cardiol ; 109(5): 440-447, Nov. 2017. tab, graf
Artigo em Inglês | LILACS | ID: biblio-887971

RESUMO

Abstract Background: Left atrial appendage closure (LAAC) is an effective alternative to oral anticoagulation (OA) for the prevention of stroke in patients with non-valvular atrial fibrillation (NVAF). Objective: To present the immediate results and late outcomes of patients submitted to LAAC and included in the Brazilian Registry of Percutaneous Left Atrial Appendage Closure. Methods: 91 patients with NVAF, high stroke risk (CHA2DS2VASc score = 4.5 ± 1.5) and restrictions to OAC (HAS-BLED score = 3.6 ± 1.0) underwent 92 LAAC procedures using either the Amplatzer cardiac plug or the Watchman device in 11 centers in Brazil, between late 2010 and mid 2016. Results: Ninety-six devices were used (1.04 device/procedure, including an additional non-dedicated device), with a procedural success rate of 97.8%. Associated procedures were performed in 8.7% of the patients. Complete LAAC was obtained in 93.3% of the successful cases. In cases of incomplete closure, no residual leak was larger than 2.5 mm. One patient needed simultaneous implantation of 2 devices. There were 7 periprocedural major (5 pericardial effusions requiring pericardiocentesis, 1 non-dedicated device embolization and 1 coronary air embolism without sequelae) and 4 minor complications. After 128.6 patient-years of follow-up there were 3 deaths unrelated to the procedure, 2 major bleedings (one of them in a patient with an unsuccessful LAAC), thrombus formation over the device in 2 cases (both resolved after resuming OAC for 3 months) and 2 strokes (2.2%). Conclusions: In this multicenter, real world registry, that included patients with NVAF and high thromboembolic and bleeding risks, LAAC effectively prevented stroke and bleeding when compared to the expected rates based on CHA2DS2VASc and HASBLED scores for this population. Complications rate of the procedure was acceptable considering the beginning of the learning curve of most of the involved operators.


Resumo Fundamento: A oclusão percutânea do apêndice atrial esquerdo (OAAE) é uma alternativa eficaz à anticoagulação oral (ACO) para a prevenção de acidente vascular cerebral (AVC) em pacientes com fibrilação atrial não-valvular (FANV). Objetivo: Apresentar os resultados imediatos e o seguimento tardio de pacientes submetidos a OAAE e incluídos no Registro Brasileiro de Oclusão Percutânea do Apêndice Atrial Esquerdo. Métodos: 91 pacientes com FANV, alto risco de AVC (escore CHA2DS2VASc = 4,5 ± 1,5) e restrição à AO (escore HAS-BLED = 3,6 ± 1,0) foram submetidos a 92 procedimentos de OAAE com as próteses Amplatzer Cardiac Plug e Watchman em 11 centros do Brasil, entre o final de 2010 e a metade de 2016. Resultados: Utilizaram-se 96 próteses no total (1,04 próteses/procedimento, incluindo-se o uso de 1 prótese não-dedicada adicional em um dos casos), obtendo-se sucesso em 97,8% dos procedimentos. Realizaram-se procedimentos associados à OAAE em 8,7% dos pacientes. Observou-se oclusão total do AAE em 93,3% dos casos com sucesso, e nos casos de oclusão incompleta, nenhum leak foi > 2,5 mm. Um paciente necessitou do implante simultâneo de 2 próteses. Houve 7 complicações maiores periprocedimento (5 derrames pericárdicos necessitando pericardiocentese, 1 embolização da prótese não-dedicada e 1 embolia aérea coronariana sem sequelas) e 4 menores. No seguimento de 128,6 pacientes-ano, houve 3 óbitos não relacionados ao procedimento, 2 sangramentos maiores (um deles em um dos casos de insucesso da OAAE), formação de trombo sobre a prótese em 2 casos (tratados com sucesso com reinstituição da ACO por 3 meses), e 2 AVCs (2,2%). Conclusões: Neste registro multicêntrico de mundo real, que incluiu pacientes com FANV e alto risco de sangramento e de eventos tromboembólicos, a OAAE foi eficaz na prevenção de AVC e sangramento quando comparada às taxas de AVC previstas pelos escores CHA2DS2VASc e HASBLED para esta população. O índice de complicações do procedimento foi aceitável, considerando se tratar do início da curva de aprendizado da maioria dos operadores envolvidos.


Assuntos
Humanos , Masculino , Feminino , Idoso , Fibrilação Atrial/cirurgia , Apêndice Atrial/cirurgia , Acidente Vascular Cerebral/prevenção & controle , Dispositivo para Oclusão Septal , Fibrilação Atrial/diagnóstico por imagem , Seguimentos , Resultado do Tratamento , Ecocardiografia Transesofagiana , Apêndice Atrial/diagnóstico por imagem , Acidente Vascular Cerebral/etiologia
3.
Rev. bras. cardiol. invasiva ; 23(2): 152-155, abr.-jun. 2015. ilus
Artigo em Português | LILACS | ID: lil-787001

RESUMO

O implante de valva aórtica transcateter (TAVI) é uma alternativa para pacientes com estenose aórtica de alto risco cirúrgico e para muitos daqueles considerados inoperáveis. Apesar de sua característica minimamente invasiva, podem ocorrer complicações relacionadas ao procedimento. Obstrução coronária durante o TAVI é uma complicação rara, com incidência inferior a 1%, mas potencialmente letal. Em nosso país, essa complicação foi encontrada em 0,72% dos procedimentos − 3 de 418 casos do Registro Brasileiro de Implante de Bioprótese Aórtica por Cateter − com mortalidade hospitalar de 100%. Apresentamos, neste relato de caso, medidas de prevenção e tratamento de oclusão coronária após o TAVI.


Transcatheter aortic valve implantation (TAVI) is an alternative for patients with aortic stenosis at high surgical risk and for many of those considered inoperable. Despite its minimally invasive features,complications related to the procedure may occur. Coronary obstruction during TAVI is a rare (incidence rate of less than 1%) but potentially lethal complication. In Brazil, this complication was found in 0.72% of procedures – three of 418 cases from the Brazilian Transcatheter Aortic Valve Implantation Registry – with an in-hospital mortality rate of 100%. This case report presents prevention and treatment measures forcoronary occlusion after TAVI.


Assuntos
Humanos , Feminino , Idoso , Estenose da Valva Aórtica/terapia , Implante de Prótese de Valva Cardíaca/métodos , Oclusão Coronária/complicações , Oclusão Coronária/terapia , Angioplastia/métodos , Artéria Femoral , Catéteres , Ecocardiografia/métodos , Fatores de Risco , Intervenção Coronária Percutânea/métodos , Stents , Valva Aórtica/cirurgia
4.
Rev. Soc. Cardiol. Estado de Säo Paulo ; 24(2): 64-69, abr.-jun. 2014. tab, ilus
Artigo em Português | LILACS | ID: lil-740491

RESUMO

A estenose aórtica é a doença vaI var cardíaca mais comum. Sua prevalência aumenta com a idade, afetando aproximadamente 3% da população com idade superior a 75 anos. Há décadas, a substituição cirúrgica da valva aórtica é o tratamento de eleição para pacientes com estenose aórtica importante sintomática, propiciando alívio dos sintomas e aumento da sobrevida. Entretanto, o risco cirúrgico aumenta com o avançar da idade e com a associação de comorbidades, o que faz com que mais de 1/3 dos idosos com estenose aórtica sintomática sejam recusados para a cirurgia. Frente a essa necessidade, Alan Cribier, em 2002, realizou o primeiro implante percutâneo de uma bioprótese valvar aórtica em seres humanos. No Brasil, a experiência com o implante valvar aórtico por cateter iniciou- se em janeiro de 2008, com a aprovação e disponibilidade do sistema CoreValve. Para avaliar os resultados desta nova modalidade de tratamento em nosso meio, a Sociedade Brasileira de Hemodinâmica e Cardiologia Intervencionista criou o Registro Brasileiro de Implante de Bioprótese Valvar Aórtica por Cateter. As evidências clínicas, empregando as próteses expansível por balão Sapien (Edwards Lifesciences) e autoexpansível CoreValve (Medtronic), indicam tratar-se de um procedimento seguro e altamente eficaz em pacientes selecionados. Atualmente, o implante de bioprótese aórtica por cateter é considerado a terapia de escolha para pacientes com estenose aórtica importante considerados inoperáveis e uma alternativa menos invasiva à cirurgia para pacientes com alto risco cirúrgico.


Aortic stenosis is the most common heart valve disease. Its prevalence increases with age, affecting approximately 3% of the population aged over 75 years. For decades, surgical aortic valve replacement has been the treatment of choice for patients with symptomatic severe aortic stenosis, providing relief of symptoms and increased survival. However, surgi cal risk increases with advancing age and with the association of comorbidities, which means that more than one third of elderly patients with symptomatic aortic stenosis are deemed inoperable. Given this unmet clinical need, Alan Cribier, in 2002, performed the first transcatheter aortic valve implantation in humans. In Brazil, the experience with transcatheter aortic valve implantation began in January 2008, with the approval and availability of the CoreValve system. To evaluate the results of this new treatment modality in Brazil, the Brazilian Society of Interventional Cardiology created the Brazilian Registry ofTranscatheter Aortic Valve Implantation. Clinical evidence, employing the balloon-expandable Sapien prosthesis (Edwards Lifesciences) and self-expanding CoreValve (Medtronic), indicate that it is a safe and highly effective procedure in selected patients. Currently, the transcatheter aortic valve implantation is considered the "gold standard" treatment for patients with severe symptomatic aortic stenosis deemed inoperable and an attractive alternative to surgical aortic valve replacement for patients at high surgical risk.


Assuntos
Humanos , Masculino , Feminino , Idoso , Estenose da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/terapia , Implante de Prótese de Valva Cardíaca/métodos , Tratamento Farmacológico , Valva Aórtica/cirurgia , Valvuloplastia com Balão/métodos , Bioprótese , Equipe de Assistência ao Paciente , Idoso , Mortalidade , Período Perioperatório
5.
Arq. bras. cardiol ; 99(2): 697-705, ago. 2012. graf, tab
Artigo em Português | LILACS | ID: lil-647716

RESUMO

FUNDAMENTO: O implante por cateter de bioprótese valvar aórtica é uma nova modalidade de tratamento para portadores de estenose aórtica inoperáveis ou de alto risco cirúrgico. Objetivo: Relatar a experiência de três anos do implante por cateter da bioprótese CoreValve. MÉTODOS: Entre janeiro de 2008 e janeiro de 2011, 35 pacientes com estenose aórtica (33 casos) ou disfunção de bioprótese valvar aórtica (dois casos) de alto risco cirúrgico foram submetidos ao implante da bioprótese CoreValve. RESULTADOS: A média de idade dos pacientes foi 81,5 ± 9 anos, e 80% apresentavam-se em classe funcional III ou IV de insuficiência cardíaca. O EuroScore foi 18,4 ± 14,3% e o STS 14,5 ± 11,6%. Obteve-se sucesso do implante em 34 (97,1%) pacientes. Após a intervenção houve redução do gradiente transvalvar de 84,9 ± 22 para 22,5 ± 9,5 mmHg e 87,1% dos pacientes evoluíram em classe funcional I ou II. A mortalidade aos 30 dias e no seguimento médio de 400 ± 298 dias foi, respectivamente, de 11,4% e 31,4%. A ocorrência de complicações hemorrágicas com risco de morte foi o único preditor independente de mortalidade cardiovascular. Acidente vascular cerebral ocorreu em 5,7% dos pacientes. Marca-passo permanente foi necessário em 32,1% dos casos no primeiro mês após o procedimento. CONCLUSÃO: O implante por cateter de bioprótese valvar aórtica é um procedimento seguro e eficaz para ser empregado em portadores de estenose aórtica de alto risco cirúrgico. O dispositivo CoreValve é eficaz no médio-prazo, em seguimento de até três anos.


BACKGROUND: Transcatheter aortic bioprosthesis implantation is a new treatment modality for patients with aortic stenosis who are inoperable or at high surgical risk. OBJECTIVE: To report the three-year experience with transcatheter CoreValve® bioprosthesis implantation. METHODS: From January 2008 to January 2011, 35 patients with aortic stenosis (33) or aortic valve bioprosthesis dysfunction (two) at high surgical risk underwent transcatheter CoreValve® bioprosthesis implantation. RESULTS: The patients' mean age was 81.5 ± 9 years, and 80% had heart failure functional class III or IV. The EuroScore was 18.4 ± 14.3% and the STS risk score was 14.5 ± 11.6%. Successful device implantation was achieved in 34 (97.1%) patients. After the intervention, a reduction in the transvalvular pressure gradient from 84.9 ± 22 to 22.5 ± 9.5 mm Hg was observed, and 87.1% of the patients progressed to functional class I or II. Thirty-day mortality and mortality in the follow-up of 400 ± 298 days were 11.4% and 31.4%, respectively. The occurrence of life-threatening hemorrhagic complications was the only independent predictor of cardiovascular mortality. Stroke occurred in 5.7% of the patients. Permanent pacemaker was required in 32.1% of the patients within the first month after the procedure. CONCLUSION: Transcatheter aortic bioprosthesis implantation is a safe and effective procedure to be used in patients with aortic stenosis at high surgical risk. The CoreValve® prosthesis proved to have mid-term efficacy in a three-year follow-up.


Assuntos
Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estenose da Valva Aórtica/terapia , Bioprótese , Cateterismo Cardíaco/métodos , Próteses Valvulares Cardíacas , Implante de Prótese de Valva Cardíaca/métodos , Cateterismo Cardíaco/efeitos adversos , Determinação de Ponto Final , Métodos Epidemiológicos , Implante de Prótese de Valva Cardíaca/efeitos adversos , Complicações Pós-Operatórias , Resultado do Tratamento
6.
Arq. bras. cardiol ; 98(6): e96-e98, jun. 2012. ilus, tab
Artigo em Português | LILACS | ID: lil-645351

RESUMO

Em pacientes com insuficiência coronariana aguda e choque cardiogênico, a mortalidade é alta. O dispositivo mais utilizado para suporte hemodinâmico é o balão intra-aórtico que, no entanto, pode ser insuficiente em pacientes com choque cardiogênico refratário. Relato de caso com dois dias de dor precordial opressiva e intensa, irradiada para membro superior esquerdo. ECG com supradesnivelamento anterior. Realizado angioplastia e implante de stent na artéria descendente anterior. Evolução com choque cardiogênico refratário ao uso de drogas vasoativas e balão intra-aórtico. Foram realizadas medidas hemodinâmicas e decidiu-se pela colocação do Impella® 2,5 por via percutânea para assistência circulatória.


Mortality is high in patients with acute coronary failure and cardiogenic shock. The most commonly used device for hemodynamic support is the intra-aortic balloon, which, however, may be insufficient in patients with refractory cardiogenic shock. This is a case report of a patient complaining of two days of intense and oppressive chest pain, radiating to the left arm. The ECG showed ST elevation. The patient was submitted to angioplasty and stent implant in the anterior descending artery and developed cardiogenic shock refractory to vasoactive drugs and intra-aortic balloon. Hemodynamic measures were carried out and we chose to use an Impella 2.5 device, by percutaneous route, for circulatory support.


Assuntos
Idoso , Feminino , Humanos , Balão Intra-Aórtico , Choque Cardiogênico/cirurgia , Angioplastia Coronária com Balão , Hemodinâmica/fisiologia , Infarto do Miocárdio/cirurgia , Stents , Choque Cardiogênico/etiologia , Resultado do Tratamento
7.
Arq. bras. cardiol ; 93(1): 15-21, jul. 2009. ilus, graf, tab
Artigo em Inglês, Espanhol, Português | LILACS | ID: lil-528231

RESUMO

FUNDAMENTO: A aterosclerose ocorre mais cedo em pacientes com diabetes mellitus tipo 1 (DM-1) e a doença arterial coronariana (DAC) constitui a mais importante causa de morte. OBJETIVO: Avaliar a prevalência e as características anatômicas da DAC em pacientes com DM-1 e insuficiência renal crônica, submetidos à diálise. MÉTODOS: Este é um estudo descritivo de 20 pacientes com DM-1 submetidos à diálise sem DAC conhecida. A DAC foi avaliada através de angiografia coronariana quantitativa (ACQ) e ultra-som intravascular (USIV). A ACQ foi realizada em todas as lesões >30 por cento, visualmente Todos os segmentos proximais de 18 mm das artérias coronárias foram analisados por USIV. Todos os outros segmentos coronarianos com estenose >30 por cento também foram analisados. RESULTADOS: A angiografia detectou 29 lesões >30 por cento em 15 pacientes (75 por cento). Onze (55 por cento) das lesões eram >50 por cento e 10 (50 por cento) >70 por cento. Treze pacientes tiveram as 3 principais artérias avaliadas pelo USIV. A aterosclerose estava presente em todos os pacientes e em todos os 51 segmentos proximais de 18 mm analisados. Esses segmentos significam que a medida do diâmetro dos vasos apresentava-se significantemente maior no USIV do que na ACQ, em todos os vasos. As imagens do ISIV de 25 (86,2 por cento) das 29 lesões >30 por cento foram obtidas. Placas fibróticas eram comuns (48 por cento) e 60 por cento apresentavam remodelamento intermediário de vasos. CONCLUSÃO: A DAC estava presente em todos os vasos de todos os pacientes com diabete tipo 1 submetidos a hemodiálise. Esses achados estão de acordo com outros estudos de autópsia, angiografia e USIV. Além disso, eles indicam a necessidade de estudos adicionais epidemiológicos e de imagem, para um melhor entendimento e tratamento de uma condição clínica complexa e grave que afeta jovens indivíduos.


BACKGROUND: In patients with type 1 diabetes mellitus, atherosclerosis occurs earlier in life and coronary artery disease (CAD) constitutes the major cause of death. OBJECTIVE: Evaluate the prevalence and anatomic characteristics of coronary artery disease (CAD) in type 1 diabetic patients with chronic renal failure undergoing hemodialysis. METHODS: This is a descriptive study of 20 patients with type 1 diabetes mellitus undergoing hemodialysis without known CAD. CAD was assessed by quantitative coronary angiography (QCA) and intravascular ultrasound (IVUS). QCA was performed in all lesions >30 percent, visually. All proximal 18-mm segments of the coronary arteries were analyzed by IVUS. All other coronary segments with stenosis >30 percent were also analyzed. RESULTS: Angiography detected 29 lesions >30 percent in 15 patients (75 percent). Eleven (55 percent) of the lesions were >50 percent and 10 (50 percent) >70 percent. Thirteen patients had all 3 major arteries interrogated by IVUS. Atherosclerosis was present in all patients and in all 51 proximal 18-mm segments analyzed. The mean vessel diameter of these segments was significantly larger at the IVUS than at the QCA, for all vessels. IVUS images of 25 (86.2 percent) of the 29 lesions >30 percent were obtained. Fibrotic plaques were common (48 percent) and 60 percent had intermediate vessel remodeling. CONCLUSION: CAD was present in all vessels of all type 1 diabetic patients undergoing hemodialysis. These findings are in agreement with other autopsy, angiography and IVUS studies. Additionally, they indicate the need for additional epidemiological and imaging studies to better understand and treat such a complex and serious clinical condition affecting young people.


FUNDAMENTO: La aterosclerosis ocurre más temprano en pacientes con diabetes mellitus tipo 1 (DM-1) y la enfermedad arterial coronaria (EAC) constituye la más importante causa de muerte. OBJETIVO: Evaluar la prevalencia y las características anatómicas de la EAC en pacientes con DM-1 e insuficiencia renal crónica, sometidos a diálisis. MÉTODOS: Este es un estudio descriptivo de 20 pacientes con DM-1 sometidos a diálisis sin EAC conocida. La EAC se evaluó mediante angiografía coronaria cuantitativa (ACC) y ultrasonido intravascular (IVUS). La ACC se realizó en todas las lesiones >30 por ciento, se llevó a cabo el análisis visual por IVUS en todos los segmentos proximales de 18 mm de las arterias coronarias. También se analizaron todos los otros segmentos coronarios con estenosis >30 por ciento. RESULTADOS: La angiografía detectó 29 lesiones >30 por ciento en 15 pacientes (75 por ciento). Once (55 por ciento) de las lesiones eran >50 por ciento y 10 (50 por ciento) >70 por ciento. Trece pacientes tuvieron las tres arterias principales evaluadas por el IVUS. La aterosclerosis estaba presente en todos los pacientes y en todos los 51 segmentos proximales de 18 mm analizados. Esos segmentos significan que la medición del diámetro de los vasos resultaba significantemente mayor en el IVUS que en la ACC, en todos los vasos. De las imágenes del IVUS se obtuvieron 25 (86,2 por ciento) de las 29 lesiones >30 por ciento. Placas fibróticas eran comunes (48 por ciento) y el 60 por ciento presentaban remodelamiento intermediario de vasos. CONCLUSIÓN: La EAC estaba presente en todos los vasos de todos los pacientes con diabetes tipo 1 sometidos a hemodiálisis. Esos hallazgos están de acuerdo con otros estudios de autopsia, angiografía e IVUS. Además de ello, indican la necesidad de estudios adicionales epidemiológicos y de imagen, para una mejor comprensión y tratamiento de una condición clínica compleja y severa que afecta a jóvenes individuos.


Assuntos
Adulto , Feminino , Humanos , Masculino , Doença da Artéria Coronariana/patologia , Vasos Coronários/patologia , Diabetes Mellitus Tipo 1/complicações , Angiopatias Diabéticas/patologia , Falência Renal Crônica/terapia , Diálise Renal , Angiografia Coronária , Doença da Artéria Coronariana , Doença da Artéria Coronariana , Vasos Coronários , Angiopatias Diabéticas , Angiopatias Diabéticas , Estudos Prospectivos , Fatores de Tempo
8.
Arq. bras. cardiol ; 77(3): 270-273, Sept. 2001. ilus
Artigo em Inglês | LILACS | ID: lil-298658

RESUMO

Intracoronary brachytherapy using beta or gamma radiation is currently the most efficient type of therapy for preventing the recurrence of coronary in-stent restenosis. Its implementation depends on the interaction among interventionists, radiotherapists, and physicists to assure the safety and quality of the method. The authors report the pioneering experience in Brazil of the treatment of 2 patients with coronary in-stent restenosis, in whom beta radiation was used as part of the international multicenter randomized PREVENT study (Proliferation REduction with Vascular ENergy Trial). The procedures were performed rapidly and did not require significant modifications in the traditional techniques used for conventional angioplasty. Alteration in the radiological protection devices of the hemodynamic laboratory were also not required, showing that intracoronary brachytherapy using beta radiation can be incorporated into the interventional tools of cardiology in our environment


Assuntos
Humanos , Feminino , Idoso , Pessoa de Meia-Idade , Braquiterapia/métodos , Doença das Coronárias/radioterapia , Stents , Doença das Coronárias , Recidiva , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA