Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros







Base de dados
Intervalo de ano de publicação
1.
Arq. bras. cardiol ; 113(5): 915-922, Nov. 2019. tab, graf
Artigo em Inglês | LILACS | ID: biblio-1055038

RESUMO

Abstract Background: Hepatopulmonary syndrome (HPS), found in cirrhotic patients, has been little studied in hepatosplenic schistosomiasis (HSS) and includes the occurrence of intrapulmonary vascular dilatations (IPVD). Contrast transesophageal echocardiography (cTEE) with microbubbles is more sensitive than contrast transthoracic echocardiography (cTTE) with microbubbles in the detection of IPVD in cirrhosis. Objective: To assess the performance of the cTEE, compared with that of cTTE, in detecting IPVD for the diagnosis of HPS in patients with HSS. Methods: cTEE and cTTE for investigation of IPVD and laboratory tests were performed in 22 patients with HSS. Agitated saline solution was injected in peripheral vein during the cTEE and cTTE procedures. Late appearance of the microbubbles in the left chambers indicated the presence of IPVD. Results of the two methods were compared by the Student's t-test and the chi-square test (p < 0.05). Results: cTEE was performed in all patients without complications. Three patients were excluded due to the presence of patent foramen ovale (PFO). The presence of IPVD was confirmed in 13 (68%) of 19 patients according to the cTEE and in only six (32%, p < 0.01) according to the cTTE. No significant differences in clinical or laboratory data were found between the groups with and without IPVD, including the alveolar-arterial gradient. The diagnosis of HPS (presence of IPVD with changes in the arterial blood gas analysis) was made in five patients by the cTEE and in only one by the cTTE (p = 0.09). Conclusion: In HSS patients, cTEE was safe and superior to cTTE in detecting IPVD and allowed the exclusion of PFO.


Resumo Fundamento: A síndrome hepatopulmonar (SHP), presente em pacientes cirróticos, é pouco estudada na esquistossomose hepatoesplênica (EHE) e inclui a ocorrência de dilatações vasculares intrapulmonares (DVP). O ecocardiograma transesofágico com contraste (ETEc) de microbolhas é mais sensível que o ecocardiograma transtorácico com contraste (ETTc) de microbolhas na identificação de DVP na cirrose. Objetivo: Avaliar o desempenho do ETEc comparado ao ETTc na identificação de DVP para diagnóstico de SHP em pacientes com EHE. Métodos: Incluímos 22 pacientes com EHE submetidos a ETEc e ETTc para pesquisa de DVP, além de exames laboratoriais. Os ETEc e ETTc foram realizados empregando-se solução salina agitada, injetada em veia periférica. A visualização tardia das microbolhas em câmaras esquerdas indicava presença de DVP. Os resultados foram comparados entre os dois métodos pelos testes t de Stu dent e qui-quadrado (significância p < 0,05). Resultados: Todos os 22 pacientes realizaram ETEc sem intercorrências. Foram excluídos três pela presença de forame oval patente (FOP), e a análise final foi realizada nos outros 19. A DVP esteve presente ao ETEc em 13 pacientes (68%) e em apenas seis ao ETTc (32%, p < 0,01). Não houve diferenças significativas nos dados clínicos e laboratoriais entre os grupos com e sem DVP, incluindo a diferença alveoloarterial de oxigênio. O diagnóstico de SHP (presença de DVP com alterações gasométricas) ocorreu em cinco pacientes pelo ETEc e em apenas um pelo ETTc (p = 0,09). Conclusão: Em pacientes com EHE, o ETEc foi seguro e superior ao ETTc na detecção de DVP não identificada ao ETTc, o que possibilitou adicionalmente excluir FOP.


Assuntos
Humanos , Masculino , Feminino , Adulto , Pessoa de Meia-Idade , Idoso , Esquistossomose/diagnóstico por imagem , Esplenopatias/diagnóstico por imagem , Ecocardiografia/métodos , Ecocardiografia Transesofagiana/métodos , Dilatação Patológica/diagnóstico por imagem , Hepatopatias Parasitárias/diagnóstico por imagem , Sensibilidade e Especificidade , Meios de Contraste , Síndrome Hepatopulmonar/diagnóstico , Síndrome Hepatopulmonar/diagnóstico por imagem , Microbolhas , Forame Oval Patente/diagnóstico
2.
Arq. bras. cardiol ; 94(1): e4-e6, jan. 2010. ilus
Artigo em Inglês, Espanhol, Português | LILACS | ID: lil-543875

RESUMO

Os pseudoaneurismas ocorrem como rara complicação do infarto do miocárdio, após rotura miocárdica, cujo processo hemorrágico é contido por aderências do pericárdio visceral, parietal - ou de ambos -, impedindo o desenvolvimento de tamponamento cardíaco. Relatamos o caso de um paciente de 55 anos, com pseudoaneurisma crônico do ventrículo esquerdo de etiologia indefinida, de longa evolução, que foi submetido a tratamento conservador.


Pseudoaneurysms occur as a rare complication of the myocardial infarction, of which hemorrhagic process is contained by adherences of the visceral or parietal pericardium - or of both - preventing the development of cardiac tamponade. We report the case of a 55-year-old patient, with a chronic left ventricular pseudoaneurysm of undetermined etiology, who was submitted to a conservative treatment.


Los pseudoaneurismas ocurren como rara complicación del infarto de miocardio, tras rotura miocárdica, con detención del proceso hemorrágico por las adherencias del pericardio visceral, parietal - o de ambos -, impidiendo el desarrollo de taponamiento cardiaco. Relatamos el caso de un paciente de 55 años, con pseudoaneurisma crónico del ventrículo izquierdo de etiología indefinida, de larga evolución, que se sometió a tratamiento conservador.


Assuntos
Humanos , Masculino , Pessoa de Meia-Idade , Falso Aneurisma/etiologia , Disfunção Ventricular Esquerda/etiologia , Falso Aneurisma/terapia , Doença Crônica , Doença das Coronárias/diagnóstico , Progressão da Doença , Disfunção Ventricular Esquerda/terapia
3.
Arq. bras. cardiol ; 93(5): 443-483, nov. 2009. tab, graf
Artigo em Inglês, Espanhol, Português | LILACS | ID: lil-536195

RESUMO

FUNDAMENTO: A ecocardiografia transesofágica (ETE) é um exame semi-invasivo amplamente utilizado e seu uso associado a sedativos poderá influenciar a segurança do procedimento. OBJETIVO: analisar aspectos da segurança da ETE associada ao uso de midazolam (MZ) e flumazenil (FL) e a influência de variáveis clínicas na taxa de eventos. MÉTODO: estudo prospectivo com 137 pacientes que realizaram ETE com MZ associado à sedação moderada. Analisamos as seguintes ocorrências: complicações com anestesia tópica, ao uso do MZ e complicações relacionadas ao procedimento. Análises uni e multivariada foram usadas para testar a influência das variáveis clínicas: idade, sexo, acidente vascular cerebral (AVC), miocardiopatia (MP), duração do exame, insuficiência mitral (IM) e dose de MZ. RESULTADOS: todos pacientes (65±16 anos; 58 por cento masculino) completaram o exame. As doses médias de MZ e FL foram de 4,3±1,9 mg e 0,28±0,2 mg, respectivamente. A duração do exame e a fração de ejeção (FE) média foram de 16.4±6.1 minutos e 60±9 por cento, respectivamente. O evento mais comum foi a hipóxia leve (SO2<90 por cento), em 11 pacientes; 3 pacientes (2 por cento) apresentaram hipóxia transitória por obstrução da via aérea superior na passagem da sonda, enquanto 8 (5,8 por cento) apresentaram hipóxia devido ao uso do MZ. Hipotensão transitória (PAS<90 mmHg) ocorreu em 1 paciente (0,7 por cento). A análise multivariada mostrou que insuficiência mitral (IM) importante, MP (FE<45 por cento) e altas doses do MZ (>5mg) tiveram associação com tais eventos (p<0,001). A FE no grupo com MP foi de 40 por cento, ao passo que, no grupo com insuficiência mitral (IM), esse percentual foi de 44 por cento, podendo ser este um fator associado a eventos clínicos neste último grupo. CONCLUSÃO: ETE com sedação tem baixas taxas de eventos. Não se observou eventos graves e não houve a necessidade de interrupção dos exames.


BACKGROUND: TEE is a semi-invasive tool broadly used and its utilization associated to sedatives drugs might to affect the procedure safety. OBJECTIVE: to analyze aspects of TEE safety associated to the use of Midazolan (MZ) and Flumazenil (FL) and the influence of the clinical variables on the event rate. METHOD: prospective study with 137 patients that underwent TEE with MZ associated to moderate sedation. We analyzed the following events: complications related with the topical anesthesia, with MZ use and with the procedure. Uni- and multivariate analyses were used to test the influence of the clinical variables: age, sex, stroke, myocardiopathy (MP), duration of the test, mitral regurgitation (MR) and the MZ dose. RESULTS: All patients (65±16 yrs; 58 percent males) finished the examination. The mean doses of MZ and FL were 4.3±1.9 mg and 0.28±0.2 mg, respectively. The duration of the examination and the mean ejection fraction (EF) were 16.4±6.1 minutes and 60±9 percent, respectively. Mild hypoxia (SO2<90 percent) was the most common event (11 patients); 3 patients (2 percent) presented transient hypoxia due to upper airway obstruction by probe introduction and 8 (5.8 percent) due to hypoxia caused by MZ use. Transient hypotension (SAP<90mmHg) occurred in 1 patient (0.7 percent). The multivariate analysis showed that severe MR, MP (EF<45 percent) and high doses of MZ (>5mg) were associated with events (p<0.001). The EF was 40 percent, in the group with MP and 44 percent in the group with severe MR and it can be a factor associated with clinical events in the last group. CONCLUSION: TEE with sedation presents a low rate of events. There were no severe events and there was no need to interrupt the examinations.


FUNDAMENTO: La ecocardiografía transesofágica (ETE) es un examen semiinvasivo ampliamente utilizado y su uso asociado a sedantes puede influir sobre la seguridad del procedimiento. OBJETIVO: Analizar aspectos de la seguridad de la ETE asociada al uso de midazolam (MZ) y flumazenil (FL) y la influencia de variables clínicas en la tasa de complicaciones. MÉTODO: Estudio prospectivo con 137 pacientes, a quienes se realizó ETE con MZ asociado a la sedación moderada. Analizamos los siguientes eventos: complicaciones con anestesia local, relacionadas al uso de MZ y complicaciones relacionadas con el procedimiento. Se utilizaron análisis uni y multivariados para evaluar la influencia de las variables clínicas: edad, sexo, accidente cerebrovascular (ACV), miocardiopatía (MP), duración del estudio, insuficiencia mitral (IM) y dosis de MZ. RESULTADOS: Todos los pacientes (65±16 años; 58 por ciento masculino) completaron el estudio. Las dosis promedio de MZ y FL fueron de 4,3±1,9 mg y 0,28±0,2 mg, respectivamente. La duración del estudio y la fracción de eyección (FE) promedio fueron de 16.4±6.1 minutos y 60±9 por ciento, respectivamente. El evento más común fue la hipoxia leve (SO2<90 por ciento), en 11 pacientes; 3 pacientes (2 por ciento) presentaron hipoxia transitoria por obstrucción de la vía aérea superior con el pasaje de la sonda, mientras que 8 (5,8 por ciento) presentaron hipoxia debido a la utilización del MZ. Un paciente (0.7 por ciento) padeció hipotensión transitoria (PAS<90 mmHg). El análisis multivariado mostró que IM significativa, MP (FE<45 por ciento) y altas dosis de MZ (>5mg) se asociaron a tales complicaciones (p<0,001). La FE en el grupo con MP fue de 40 por ciento, mientras que, en el grupo con insuficiencia mitral, ese porcentaje fue de 44 por ciento, pudiendo ser éste un factor asociado a complicaciones clínicas en este último grupo. CONCLUSIÓN: ETE con sedación presenta bajas tasas de ...


Assuntos
Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Anestésicos Intravenosos/efeitos adversos , Sedação Consciente/efeitos adversos , Ecocardiografia Transesofagiana/efeitos adversos , Flumazenil/efeitos adversos , Midazolam/efeitos adversos , Anestésicos Intravenosos/administração & dosagem , Hipóxia/induzido quimicamente , Hipóxia/epidemiologia , Brasil/epidemiologia , Relação Dose-Resposta a Droga , Ecocardiografia Transesofagiana/métodos , Estudos de Viabilidade , Flumazenil/administração & dosagem , Hospitais Gerais , Análise Multivariada , Midazolam/administração & dosagem , Insuficiência da Valva Mitral/patologia , Estudos Prospectivos , Fatores de Risco , Volume Sistólico/efeitos dos fármacos
4.
Rev. bras. cir. cardiovasc ; 24(2): 233-238, abr.-jun. 2009. ilus
Artigo em Inglês, Português | LILACS | ID: lil-525563

RESUMO

OBJETIVO: A troca valvar aórtica é procedimento rotineiro, envolve substituição da valva nativa/prótese. Na maioria destes pacientes o risco é aceitável, porém, em alguns casos, o risco predito pode justificar contra-indicação. O implante de valva aórtica minimamente invasivo transcateter e sem circulação extracorpórea (CEC) tem se mostrado viável, com menor morbi-mortalidade. O objetivo deste trabalho foi desenvolver bioprótese aórtica, montada em cateter, para implante sem CEC. MÉTODOS: Após desenvolvimento em animais, três pacientes com EuroSCORE elevado foram submetidos ao implante. Caso 1: portador de bioprótese com disfunção; Caso 2: estenose aórtica grave; Caso 3: disfunção de bioprótese aórtica. Após minitoracotomia e sob controle ecocardiográfico e fluoroscópico, cateter-balão foi posicionado sobre posição aórtica e insuflado. Após, segundo cateter-balão, com endoprótese valvada, foi posicionado e liberado sob alta frequência ventricular. Controles angiográficos e ecocardiográficos foram realizados e pacientes encaminhados para UTI. RESULTADOS: No primeiro caso foi possível implante sem CEC com resultados adequados. Evoluiu com melhora da função ventricular. Cursou com broncopneumonia, fístula traqueo-esofágica e óbito por mediastinite. Necropsia confirmou bom posicionamento valvar e preservação dos folhetos. O segundo caso apresentou migração do dispositivo após insuflação do balão, necessidade de esternotomia mediana de urgência, CEC e troca valvar convencional. O paciente evoluiu bem, recebendo alta da UTI 14 dias após procedimento e sem complicações. Cursou com infecção respiratória, choque séptico e óbito no 60º pós-operatório. O terceiro caso foi submetido a implante com sucesso. CONCLUSÃO: O implante de bioprótese transapical montada em cateter sem CEC mostrou ser procedimento factível. Detalhes técnicos e a curva de aprendizado demandam discussão.


OBJECTIVE: The aortic valve replacement is a routine procedure, and involves replacement of the native valve/prosthesis. In most of the patients who undergo such procedure the risk is acceptable, but in some cases, such risk can justify contraindication. The minimally invasive transcatheter aortic valve implantation without cardiopulmonary bypass (CPB) has been shown to be viable, with lower morbidity and mortality. The aim of this study was to develop a catheter-mounted aortic bioprosthesis for implantation without CPB. METHODS: After developing in animals, three patients with high EuroSCORE underwent implantation. Case 1: patients with bioprosthesis dysfunction; Case 2: severe aortic stenosis; Case 3: dysfunction of aortic bioprosthesis. After minithoracotomy and under echocardiographic and fluoroscopic control, a balloon catheter was placed on aortic position and inflated. After, a second balloon with valved endoprosthesis was positioned and released under high ventricular rate. Echocardiographic and angiographic controls were performed and the patients were referred to ICU. RESULTS: In the first case, implantation without CPB was possible with appropriate results. The patient evolved with improvement of ventricular function. After, this patient developed bronchopneumonia, tracheoesophageal fistula and died due to mediastinitis. Autopsy confirmed proper valve positioning and leaflets preservation. The second case showed the device migration after inflation of the balloon, with the need for urgent median sternotomy, CPB and conventional valve replacement. This patient evolved well and was discharged from the ICU on the 14th postoperative day without complications. This patient developed respiratory infection, septic shock and died on the 60th postoperative day. The patient from the third case underwent successful implantation. CONCLUSION: The off-pump transapical implantation of catheter-mounted bioprosthesis was shown to be a feasible ...


Assuntos
Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estenose da Valva Aórtica/terapia , Valva Aórtica/cirurgia , Bioprótese , /instrumentação , Próteses Valvulares Cardíacas , Implante de Prótese de Valva Cardíaca/métodos , Ponte Cardiopulmonar , Evolução Fatal , Implante de Prótese de Valva Cardíaca/efeitos adversos , Desenho de Prótese , Falha de Prótese , Reoperação , Medição de Risco
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA