1.
Arq. bras. cardiol ; Arq. bras. cardiol;108(6): 546-551, June 2017. tab, graf
Artigo em Inglês | LILACS, Sec. Est. Saúde SP, SESSP-IDPCPROD, Sec. Est. Saúde SP | ID: biblio-887880

RESUMO

Abstract Background: Chagas disease continues to be a serious public health problem, and accounts for 25-30% of the indications for cardiac stimulation in Brazil. Objective: To assess clinical and epidemiological characteristics of patients with Chagas disease, younger than 18 years, who had undergone pacemaker implantation in Brazil between 1994 and 2011, and its temporal trend. Methods: This was a cross-sectional analysis of data from the Brazilian Pacemaker Registry database. The following variables were analyzed: year when pacemaker was implanted, location, age, sex, ethnic group, functional class and the main electrocardiographic findings at baseline. Results: In a total of 183,123 implants performed between 1994 and 2011, 214 implants of cardiac stimulation device in Chagas disease patients aged younger than 18 years were identified. Mean age at implantation was 5.6 ± 6.2 years. Second- and third-degree atrioventricular blocks corresponded to 71% of indications for pacemaker implantation. Fifty-six percent of the procedures were performed in the southeast region. Regarding the total number of pacemaker implants per year, there was a remarkable increase in the implants for all causes. However, time series analysis of the implants in Chagas disease patients younger than 18 years revealed a significant reduction in the annual number of implants. Conclusion: There has been an important reduction in the number of pacemaker implantations among children and adolescents with Chagas disease, suggesting a reduction in the vertical transmission of the parasite.


Resumo Fundamento: A doença de Chagas mantém-se como sério problema de saúde pública e tem sido responsável por aproximadamente 25% a 30% das indicações de estimulação cardíaca no Brasil. Objetivo: Estudar as características clínicas e epidemiológicas dos pacientes menores de 18 anos portadores de doença de Chagas submetidos a implante de marca-passo no território brasileiro entre 1994 e 2011, e sua tendência temporal. Métodos: Trata-se de um estudo retrospectivo que utilizou informações coletadas pelo Registro Brasileiro de Marca-passo. As variáveis analisadas foram: ano do implante, localidade, idade, sexo, grupo étnico dos pacientes; classificação funcional e os principais achados eletrocardiográficos de base. Resultados: Em um total de 183 123 implantes realizados entre 1994 e 2011, foram identificados 214 implantes de dispositivos de estimulação cardíaca em portadores de doença de Chagas com idade inferior a 18 anos. A média de idade no momento do implante foi de 5,6 ± 6,2 anos. Bloqueios atrioventriculares de 2º e 3º graus foram responsáveis por 71% das indicações. Dos procedimentos, 55,6% foram realizados na região sudeste. Em relação ao total de implantes de marca-passo por ano, observamos um aumento importante e significante de implante por todas as causas. Entretanto, quando avaliamos a série temporal de implantes em pacientes com doença de Chagas menores que 18 anos, observamos uma redução expressiva e significativa no número anual de implantes. Conclusão: Observa-se uma redução importante do número de implantes de marca-passo em crianças e adolescente chagásicos, o que sugere uma redução da transmissão vertical do parasita.


Assuntos
Humanos , Criança , Adolescente , Marca-Passo Artificial/estatística & dados numéricos , Cardiomiopatia Chagásica/terapia , Fatores Socioeconômicos , Brasil/epidemiologia , Cardiomiopatia Chagásica/epidemiologia , Incidência , Estudos Transversais , Resultado do Tratamento
2.
RELAMPA, Rev. Lat.-Am. Marcapasso Arritm ; 28(4): 175-181, out.-dez. 2015. ilus, tab, graf
Artigo em Português | LILACS, Sec. Est. Saúde SP, SESSP-IDPCPROD, Sec. Est. Saúde SP | ID: lil-788755

RESUMO

A cardiomiopatia induzida por marcapasso é uma forma de cardiomiopatia que ocorre em coraçõesestruturalmente normais após o implante de marcapasso convencional. A incidência pode chegar a 20% ao longode dez anos. A ressincronização biventricular é o tratamento de escolha para essa enfermidade. Relata-se o casode uma paciente do sexo feminino, com 77 anos de idade, portadora de implante de marcapasso bicameral por bloqueio atrioventricular de 2o grau Mobitz II, bloqueio de ramo esquerdo intermitente e síncope. A paciente evoluiu com disfunção ventricular grave e dispneia aos esforços habituais sete anos após o implante. Foi proposto upgrade para ressincronizador biventricular e após um ano houve remodelamento reverso do ventrículo esquerdo, com normalização da fração de ejeção e controle dos sintomas.


Pacing-induced cardiomyopathy is a cardiomyopathy that occurs in structurally normal hearts afterconventional pacemaker implant. The incidence may reach 20% in 10 years. Biventricular resynchronization is the choice treatment to this disorder. We report a female, 77 year-old patient, with a pacemaker for Mobitz typeII second-degree atrioventricular block, left bundle branch block and syncope. The patient evolved with severeventricular dysfunction and dyspnea during daily activities 7 years after implant. An upgrade to biventricularresynchronization was suggested and within 1 year there was reverse left ventricular remodeling with normalizationof ejection fraction and symptom control.


Assuntos
Humanos , Feminino , Idoso , Cardiomiopatias/fisiopatologia , Cardiomiopatias/terapia , Marca-Passo Artificial , Terapia de Ressincronização Cardíaca/métodos , Ecocardiografia/métodos , Eletrocardiografia/métodos , Resultado do Tratamento , Ventrículos do Coração , Átrios do Coração
3.
Rev. bras. cir. cardiovasc ; Rev. bras. cir. cardiovasc;30(2): 139-147, Mar-Apr/2015. tab, graf
Artigo em Inglês | LILACS, Sec. Est. Saúde SP | ID: lil-748943

RESUMO

Abstract Introduction: Although rare, the atrioesophageal fistula is one of the most feared complications in radiofrequency catheter ablation of atrial fibrillation due to the high risk of mortality. Objective: This is a prospective controlled study, performed during regular radiofrequency catheter ablation of atrial fibrillation, to test whether esophageal displacement by handling the transesophageal echocardiography transducer could be used for esophageal protection. Methods: Seven hundred and four patients (158 F/546M [22.4%/77.6%]; 52.8±14 [17-84] years old), with mean EF of 0.66±0.8 and drug-refractory atrial fibrillation were submitted to hybrid radiofrequency catheter ablation (conventional pulmonary vein isolation plus AF-Nests and background tachycardia ablation) with displacement of the esophagus as far as possible from the radiofrequency target by transesophageal echocardiography transducer handling. The esophageal luminal temperature was monitored without and with displacement in 25 patients. Results: The mean esophageal displacement was 4 to 9.1cm (5.9±0.8 cm). In 680 of the 704 patients (96.6%), it was enough to allow complete and safe radiofrequency delivery (30W/40ºC/irrigated catheter or 50W/60ºC/8 mm catheter) without esophagus overlapping. The mean esophageal luminal temperature changes with versus without esophageal displacement were 0.11±0.13ºC versus 1.1±0.4ºC respectively, P<0.01. The radiofrequency had to be halted in 68% of the patients without esophageal displacement because of esophageal luminal temperature increase. There was no incidence of atrioesophageal fistula suspected or confirmed. Only two superficial bleeding caused by transesophageal echocardiography transducer insertion were observed. Conclusion: Mechanical esophageal displacement by transesophageal echocardiography transducer during radiofrequency catheter ablation was able to prevent a rise in esophageal luminal temperature, helping to avoid ...


Resumo Introdução: Apesar de rara, a fístula átrio-esofágica é uma das complicações mais temidas na ablação por radiofrequência da fibrilação atrial pelo alto risco de mortalidade. Objetivo: Este é um estudo prospectivo controlado, realizado durante a ablação por radiofrequência da fibrilação atrial regular, para testar se o deslocamento do esôfago ao manipular o transdutor de ecocardiografia transesofágica poderia ser usado para a proteção de esôfago. Métodos: Setecentos e quatro pacientes (158 mulheres e 546 homens [22,4%/77,6%]; 52,8±14 [17-84] anos), com EF média igual a 0,66±0,8 e com fibrilação atrial refratária ao tratamento medicamentoso, foram submetidos à terapia híbrida com ablação por radiofrequência (isolamento convencional das veias pulmonares e ninhos de fibrilação atrial e ablação de taquicardia de background) com deslocamento do esôfago o mais longe possível do alvo da radiofrequência por manuseio do transdutor de ecocardiografia transesofágica. A temperatura luminal esofágica foi monitorada com e sem deslocamento em 25 pacientes. Resultados: O deslocamento esofágico significativo foi de 4 a 9,1 centímetros (5,9±0,8 cm). Em 680 dos 704 pacientes (96,6%), isso foi o suficiente para permitir a entrega completa e segura de radiofrequência (30W/40ºC/cateter irrigado ou 50W/60ºC/cateter de 8 milímetros) sem sobreposição do esôfago. As alterações médias de temperatura luminal esofágica com e sem deslocamento de esôfago foram de 0,11±0,13ºC versus 1,1±0,4ºC, respectivamente, P<0,01. A radiofrequência teve que ser interrompida em 68% dos pacientes sem deslocamento de esôfago devido ao aumento da temperatura luminal esofágica. Não houve nenhum caso, suspeito ou confirmado, de fístula átrio-esofágica. Foram observados apenas dois sangramentos superficiais causados por inserção do transdutor de ecocardiografia transesofágica. Conclusão: O deslocamento mecânico do esôfago pelo transdutor de ecocardiografia transesofágico durante ...


Assuntos
Humanos , Masculino , Feminino , Adolescente , Adulto , Pessoa de Meia-Idade , Idoso , Idoso de 80 Anos ou mais , Adulto Jovem , Fibrilação Atrial/cirurgia , Cardiomiopatias/prevenção & controle , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Fístula Esofágica/prevenção & controle , Fístula/prevenção & controle , Fibrilação Atrial , Cardiomiopatias/etiologia , Ablação por Cateter/instrumentação , Ecocardiografia Transesofagiana/instrumentação , Fístula Esofágica/etiologia , Esôfago/anatomia & histologia , Esôfago/lesões , Esôfago , Fístula/etiologia , Átrios do Coração/cirurgia , Átrios do Coração , Estudos Prospectivos , Reprodutibilidade dos Testes , Fatores de Risco , Temperatura , Resultado do Tratamento
4.
Arq. bras. cardiol ; Arq. bras. cardiol;73(6): 485-98, Dec. 1999. ilus, tab
Artigo em Português, Inglês | LILACS | ID: lil-262243

RESUMO

OBJECTIVE: To describe a new more efficient method of endocardial cardiac stimulation, which produces a narrower QRS without using the coronary sinus or cardiac veins. METHODS: We studied 5 patients with severe dilated cardiomyopathy, chronic atrial fibrillation and AV block, who underwent definitive endocardial pacemaker implantation, with 2 leads, in the RV, one in the apex and the other in the interventricular septum (sub pulmonary), connected, respectively, to ventricular and atrial bicameral pacemaker outputs. Using Doppler echocardiography, we compared, in the same patient, conventional (VVI), high septal ("AAI") and bifocal ("DDT" with AV interval @ 0) stimulation. RESULTS: The RV bifocal stimulation had the best results with an increase in ejection fraction and cardiac output and reduction in QRS duration, mitral regurgitation and in the left atrium area (p < or = 0.01). The conventional method of stimulation showed the worst result. CONCLUSION: These results suggest that, when left ventricular stimulation is not possible, right ventricular bifocal stimulation should be used in patients with severe cardiomyopathy where a pacemaker is indicated.


Assuntos
Humanos , Masculino , Feminino , Adulto , Pessoa de Meia-Idade , Cardiomiopatia Dilatada/terapia , Marca-Passo Artificial , Fibrilação Atrial/terapia , Cardiomiopatia Dilatada , Doença Crônica , Eletrodos Implantados , Bloqueio Cardíaco/terapia , Ventrículos do Coração , Insuficiência da Valva Mitral , Insuficiência da Valva Mitral/terapia