Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 9 de 9
Filtrar
Mais filtros







Base de dados
Intervalo de ano de publicação
1.
Rev. bras. cir. cardiovasc ; 36(5): 639-647, Sept.-Oct. 2021. tab
Artigo em Inglês | LILACS | ID: biblio-1351659

RESUMO

Abstract Introduction: Cardiac pacemaker (PM) therapy is of paramount importance. PM use increases with age, with an estimated increased use of 70% to 80% in patients over 65 years. This study evaluated the perception of the health-related quality of life (HRQoL) of elderly patients with PM, comparing them with patients without PM, by applying two quality of life questionnaires: EuroQoL 5-dimensions (EQ-5D) and 36-Item Short Form Health Survey (SF-36). Methods: This study included elderly patients divided into a group with PM and another without PM. Information on HRQoL was obtained using the EQ-5D and SF-36 questionnaires. Results: The study involved 104 elderly patients with PM and 150 without PM. The distribution of responses to the EQ-5D was similar between groups. Statistical differences within the gender variable in the group of elderly people with PM were significant for the mobility, habitual activities, and anxiety/depression domains and for the average EQoL utility score and visual analogue scale (EQ-VAS). Elderly patients with PM presented significant differences between New York Heart Association classes 1 and 2 for the mobility domain and EQ-VAS, while those evaluated through SF-36 presented higher averages in vitality, general health status, and pain. However, a different analysis was observed in the physical aspect domain. Conclusion: The SF-36 demonstrated that elderly patients with PM had an HRQoL similar to or greater than those without PM. However, the results of the EQ-5D did not show significant differences regarding the implantation of PM and HRQoL between the two groups of elderly individuals in the study.


Assuntos
Humanos , Idoso , Marca-Passo Artificial , Qualidade de Vida , Medição da Dor , Nível de Saúde , Inquéritos e Questionários
2.
Rev. bras. cir. cardiovasc ; 33(1): 82-88, Jan.-Feb. 2018. tab, graf
Artigo em Inglês | LILACS | ID: biblio-897975

RESUMO

Abstract Introduction: Chagas disease represents an important health problem with socioeconomic impacts in many Latin-American countries. It is estimated that 20% to 30% of the people infected by Trypanosoma cruzi will develop chronic Chagas cardiomyopathy (CCC), which is generally accompanied by heart failure (HF). Cardiac resynchronization therapy (CRT) may be indicated for patients with HF and electromechanical dysfunctions. Objective: The primary endpoint of this study was to analyze the response to CRT in patients with CCC, while the secondary endpoint was to estimate the survival rates of CRT responder patients. Methods: This is an observational, cross-sectional and retrospective study. The records of 50 patients with CRT pacing devices implanted between June 2009 and March 2017 were analyzed. For statistical analyses, Pearson's correlation was used along with Student's t-test, and survival was analyzed using the Kaplan-Meier method. A P value of <0.05 was considered significant. Results: Out of 50 patients, 56% were male, with a mean age of 63.4±13.3 years and an average CRT duration of 61.2±21.7 months. The mean QRS duration was 150.12±12.4 ms before and 116.04±2.2 ms after the therapy (P<0.001). The mean left ventricular ejection fractions (LVEF) were 29±7% and 39.1±12.2% before and after CRT, respectively (P<0.001). A total of 35 (70%) patients had a reduction of at least one New York Heart Association (NYHA) functional class after six months of therapy (P=0.014). The survival rate after 72 months was 45%. Conclusion: This study showed clinical improvement and a nonsignificant survival rate in patients with CCC after the use of CRT.


Assuntos
Humanos , Masculino , Feminino , Pessoa de Meia-Idade , Cardiomiopatia Chagásica/mortalidade , Cardiomiopatia Chagásica/terapia , Terapia de Ressincronização Cardíaca/métodos , Análise de Sobrevida , Doença Crônica , Estudos Transversais , Estudos Retrospectivos
3.
Trab. educ. saúde ; 13(3): 773-796, set.-dez. 2015.
Artigo em Português | LILACS | ID: lil-763378

RESUMO

ResumoEste artigo trata de uma pesquisa qualitativa sobre as práticas e políticas curriculares relacionadas à formação médica. O método adotado foi o materialismo histórico dialético, num estudo comparado de dois casos. A amostra foi intencional, com recorte em dois cursos de Medicina: o da Pontifícia Universidade Católica de Goiás (Brasil) e o da Faculdade de Ciências da Saúde, da Universidade da Beira do Interior (Portugal). O objetivo geral era comparar as políticas curriculares para o ensino médico nos dois países e analisar as práticas de organização curricular vigentes nas duas instituições tendo em vista as políticas de cada país. Filosoficamente, a pesquisa se fundamentou na teoria do agir comunicativo de Habermas. As aproximações entre os dois cursos perseveram na matriz curricular com o ensino-aprendizagem centrado no aluno e no perfil do egresso. Os maiores distanciamentos se evidenciaram na proposta de inserção social, preconizada pela Pontifícia Universidade Católica de Goiás, e no pressuposto da pesquisa e internacionalização da Faculdade de Ciências da Saúde, da Universidade da Beira do Interior. Concluiu-se que há necessidade de solidificação dos projetos pedagógicos atuais e de adoção de uma escola reflexiva com propostas reais, no sentido de vislumbrar a possibilidade de transformações sociais na realidade concreta.


AbstractThis article is a qualitative survey of curricular practices and policies related to medical training. The method used was dialectical historical materialism based on a comparative study of two cases. The sample was intentional, making a cross section of two medical schools: the Catholic University of Goiás (Brazil) and the College of Health Sciences of the University of Beira Interior (Portugal). The overall goal was to compare the curricular policies for medical education in both countries and to analyze the curriculum organization practices prevailing in the two institutions with a view of each country's policies. Philosophically, the study was based on Habermas’ theory of communicative action. The similarities between the two courses remain in the curricular matrix, with teaching-learning focused on the student and on the graduate's profile. The greatest differences appeared in the social inclusion proposal advocated by the Catholic University of Goiás, and in the assumption of research and internationalization of the College of Health Sciences of the University of Beira Interior. It was concluded that there is a need to solidify the current educational projects and to adopt a reflective school with real proposals aiming to gain a glimpse into the possibility of social change in concrete reality.


ResumenEste artículo trata de una investigación cualitativa sobre las prácticas y políticas curriculares relacionadas con la formación médica. El método adoptado fue el materialismo histórico dialéctico, en un estudio comparado de dos casos. La muestra fue intencional, con recorte en dos cursos de Medicina: el de la Pontificia Universidad Católica de Goiás (Brasil) y el de la Facultad de Ciencias de la Salud, de la Universidad de Beira do Interior (Portugal). El objetivo general era comparar las políticas curriculares para la enseñanza médica en los dos países y analizar las prácticas de organización curricular vigentes en las dos instituciones, teniendo en vista las políticas de cada país. Filosóficamente, la investigación se fundamentó en la teoría de la acción comunicativa de Habermas. Las aproximaciones entre los dos cursos perseveran en la matriz curricular con la enseñanza-aprendizaje centrada en el alumno y en el perfil del egresado. Los mayores distanciamientos se pusieron de manifiesto en la propuesta de inserción social, preconizada por la Pontificia Universidad Católica de Goiás, y en el presupuesto de la investigación e internacionalización de la Facultad de Ciencias de la Salud, de la Universidad de Beira do Interior. Se concluyó que hay necesidad de solidificación de los proyectos pedagógicos actuales y de adopción de una escuela reflexiva con propuestas reales, en el sentido de vislumbrar la posibilidad de transformaciones sociales en la realidad concreta.


Assuntos
Humanos , Saúde , Currículo , Educação Médica , Política de Saúde
4.
Rev. bras. cir. cardiovasc ; 30(3): 311-315, July-Sept. 2015. tab, ilus
Artigo em Inglês | LILACS | ID: lil-756516

RESUMO

AbstractIntroduction:Technological progress of pacemakers has allowed the association of two or more sensors in one heart rate system response. The accelerometer sensor measures the intensity of the activity; it has a relatively rapid response to the beginning of it, however, it may present insufficient response to less strenuous or of less impact exercise. The minute ventilation sensor changes the pacing rate in response to changes in respiratory frequency in relation to tidal volume, allowing responses to situations of emotional stress and low impact exercises.Objective:To evaluate the cardiorespiratory response of the accelerometer with respect to the blended sensor (BS=accelerometer sensor+minute ventilation sensor) to exercise in chagasic patients undergoing cardiopulmonary exercise test.Methods:This was a prospective, observational, randomized, cross-sectional study. Patients who met the inclusion criteria were selected. The maximum heart rate of the sensor was programmed by age (220-age). The results were analyzed through t test with paired samples (P<0.05).Results:Sample was comprised of 44 patients, with a mean age of 66±10.4 years, 58% were female, 54% as first implant, in 74% were functional class I and 26% were functional class II, left ventricular ejection fraction was 58±7. As for the cardiopulmonary test, maximum expected heart rate and VO2 were not achieved in both the accelerometer sensor and the blended sensor, however, metabolic equivalent in the blended sensor was higher than the expected, all data with P<0.001.Conclusion:Even though the maximal heart rate was not reached, the blended sensor provided a physiological electrical sequence when compared to the accelerometer sensor, providing better physical fitness test in cardiopulmonary hemodynamics and greater efficiency.


ResumoIntrodução:O progresso tecnológico dos marca passos permitiu a associação de dois ou mais sensores em um único sistema de resposta de frequência cardíaca. O sensor acelerômetro afere a intensidade da atividade, possui uma resposta relativamente rápida ao início da mesma, porém pode apresentar respostas insuficientes a exercícios físicos menos intensos ou de menor impacto. O sensor volume-minuto altera a taxa de estimulação cardíaca em resposta à variação da frequência respiratória quanto ao volume corrente, permitindo, assim, respostas a situações de estresse emocional e exercícios de baixo impacto.Objetivo:Avaliar a resposta cardiorrespiratória do acelerômetro em relação ao duplo sensor ao exercício em pacientes chagásicos submetidos ao teste ergoespirométrico.Métodos:Pesquisa prospectiva, observacional, randomizada e cruzada. Foram selecionados pacientes que preenchiam os critérios de inclusão. A frequência cardíaca máxima do sensor foi programada por idade (220-idade). Os resultados obtidos foram analisados pelo Teste T com amostras pareadas (P<0,05).Resultados:Amostra de 44 pacientes, com idade média de 66±10,4, com 58% do sexo feminino, 54% como primeiro implante, classe funcional I em 74% e II em 26%, fração de ejeção do ventrículo esquerdo de 58±7. Quanto ao ergoespirométrico, a frequência cardíaca máxima prevista e a VO2 máxima prevista não foram atingidas tanto no sensor acelerômetro quanto no sensor volume-minuto, contudo, o equivalente metabólico no sensor volume- minuto foi superior à prevista, todos os dados com P<0,001.Conclusão:Apesar da frequência cardíaca máxima não ter sido atingida, o duplo sensor proporcionou uma sequência elétrica mais fisiológica quando comparado ao sensor acelerômetro.


Assuntos
Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estimulação Cardíaca Artificial , Doença de Chagas/fisiopatologia , Teste de Esforço , Frequência Cardíaca/fisiologia , Marca-Passo Artificial , Acelerometria/instrumentação , Estudos Transversais , Consumo de Oxigênio , Estudos Prospectivos , Distribuição Aleatória , Valores de Referência , Taxa Respiratória/fisiologia , Fatores de Tempo , Volume de Ventilação Pulmonar/fisiologia
5.
RELAMPA, Rev. Lat.-Am. Marcapasso Arritm ; 26(2): 71-75, abr.-jun .2013.
Artigo em Português | LILACS | ID: lil-711864

RESUMO

Diversos estudos têm sido realizados a fim de mostrar a eficácia dos algoritmos na redução dos episódios da fibrilação atrial (FA). Dentre eles, destaca-se o ADOPT A (Atrial Dynamic Overdrive Pacing Trial - A), com o objetivo de avaliar a eficácia de um algoritmo de overpace atrial dinâmico (DAO - dynamic atrial overdrive) na redução de episódios de fibrilação atrial. Objetivo primário: Analisar os efeitos adversos do uso em longo prazo da sobre-estimulação atrial dinâmica em portadores de marcapasso para doença do nó sinusal do tipo síndrome braditaquicardia. Objetivo secundário: Avaliar a prevalência de possíveis efeitos adversos com o algoritmo e as consequências da FA, como: acidente vascular encefálico, embolia pulmonar, alterações cardíacas e outras causas. Método: Estudo observacional, retrospectivo, descritivo, no qual foi realizada a análise dos dados dos pacientes que implantaram marcapasso com software de sobre-estimulação atrial. Critério de inclusão: portador de MP com software overdrive programado em DDD cuja indicação baseou-se na presença de doença do nó sinusal do tipo síndrome braditaquicardia, em acompanhamento por um período mínimo de 48 meses. A coleta de dados foi feita por meio de consulta ao prontuário do paciente. Resultados: No que tange aos dados telemétricos encontrados, os diagnósticos dos 20 pacientes da amostra refletiram em uma média de 79,09 ± 5,39 episódios de troca (AMS), com janela em ciclos estimulados (OPC) de 28,54 ± 9,91, respeitando uma taxa básica de estímulos já programada de acordo com a mudança de modo. A frequência básica (BR) atingiu 62,9 ± 5,16 bpm em média.


Several studies have been conducted to demonstrate the effectiveness of algorithms in reducing atrial fibrillation episodes (AF). Among them, we highlight ADOPT A (Atrial Dynamic Overdrive Pacing Trial - A), with the aim of evaluating the dynamic algorithm overpace effectiveness (DAO - dynamic atrial overdrive) in reducing atrial fibrillation episodes. Primary Objective: Analyze database looking for long-term adverse effects of DAO in patients with pacemaker for sinus disease in type bradycardia-tachycardia syndrome. Secondary Objective: Evaluate the prevalence of possible adversities with the algorithm and consequences of FA as stroke, pulmonary embolism, cardiac abnormalities and other causes. Method: The project is an observational, retrospective, descriptive trial and analyzed data of patients whose pacemaker was implanted using an atrial overstimulation software. This protocol was approved by the ethics committee of the Catholic University of Goiás on March 04, 2013, with protocol number 210 302. Inclusion criteria: patients using a pacemaker implanted by an overdrive software programmed in DDD within a minimum of four (4) years, whose indication was based on the presence of sinus node disease type bradycardia-tachycardia syndrome. Data collection was obtained by assessing the patient's chart...


Assuntos
Humanos , Masculino , Feminino , Idoso , Estimulação Cardíaca Artificial/efeitos adversos , Marca-Passo Artificial/efeitos adversos , Síndrome do Nó Sinusal/complicações , Ablação por Cateter/métodos , Sistemas Computadorizados de Registros Médicos , Prevalência , Fatores de Tempo
6.
RELAMPA, Rev. Lat.-Am. Marcapasso Arritm ; 26(1): 24-28, jan.-mar. 2013.
Artigo em Português | LILACS | ID: lil-682803

RESUMO

O diabetes mellitus é um dos principais problemas de saúde pública, responsável por cerca de 5% de todasas mortes a cada ano e com prevalência e morbimortalidade em ascensão no Brasil e no mundo. Níveis glicêmicosacima do normal, mas sem preencher os critérios para diabetes mellitus, constituem o pré-diabetes. Estudosdemonstram que o diabetes mellitus está associado a alterações do sistema nervoso autônomo, constituindo fatorfisiopatológico importante no desenvolvimento de comorbidades, como a neuropatia autonômica cardiovascular.Porém, poucos estudos correlacionaram essas alterações com o período pré-diabetes, embora haja indícios de quepossam estar presentes já nessa fase. Objetivos: Demonstrar, por meio da variabilidade da frequência cardíaca, aexistência de correlação entre alterações do sistema nervoso autônomo, em pacientes pré-diabéticos e diabéticos.Métodos: Foram estudados 40 pacientes, divididos em quatro grupos: (A) controle; (B) pré-diabéticos; (C)portadores de diabetes mellitus tipo 2 controlados; e (D) portadores de diabetes mellitus tipo 2 não controlados. Osdados obtidos no Holter 24h foram correlacionados com os níveis glicêmicos de jejum e a hemoglobina glicada,além de dados clínicos, como pressão arterial, índice de massa corporal e circunferência abdominal. Resultados:Foi encontrada associação significativa ao se comparar o SDNN do grupo controle com pacientes diabéticoscontrolados (p=0,026) e não controlados (p=0,022). Conclusões: Os resultados encontrados sugerem que ospacientes diabéticos apresentam distúrbios na modulação autonômica cardíaca, conforme descrito na literatura,não sendo encontrada disautonomia cardíaca significativa em pré-diabéticos.


Background: Diabetes mellitus (DM) is a major public health problem, accounting for about 5% ofall deaths each year and rising prevalence and morbidity and mortality in Brazil and worldwide. Pre-diabetes isconstituted by blood glucose levels over the normal range which do not meet DM criteria. Studies have shown thatDM is associated with changes in the autonomic nervous system and is an important pathophysiological factorin the development of comorbidities such as cardiovascular autonomic neuropathy. However, few studies havecorrelated these changes with pre-diabetes although there are indications that they may be present at this stage.Objectives: Demonstrate a correlation between the autonomic nervous system, pre-diabetes and diabetes changesusing heart rate variability. Methods: We studied 40 patients, divided into four groups: (A) control; (B) prediabetics;(C) patients with controlled type 2 diabetes mellitus, (D) patients with uncontrolled type 2 diabetes.Data obtained by the 24-hour Holter were correlated with fasting glucose levels and glycated hemoglobin, inaddition to clinical data such as blood pressure, BMI and waist circumference. Results: A significant associationwas observed when the control group SDNN was compared to that of controlled (p=0.026) and uncontrolled (p=0.022) diabetic patients. Conclusions: Based on the results we can suggest that diabetic patients have cardiacautonomic modulation disturbances, as described in the literature and significant cardiac dysautonomia was notobserved in pre-diabetics.


Fundamento: La diabetes mellitus (DM) es uno de los principales problemas de salud pública,responsable de un 5% de la totalidad de las muertes todos los años y con prevalencia y morbimortalidad enascensión en Brasil y en el mundo. La pre diabetes comprende niveles glucémicos arriba de lo considerado normal,pero no rellena los criterios para DM. Estudios demuestran que la DM está asociada con alteraciones del sistemanervioso autónomo, constituyéndose en importante factor fisiopatológico para el desarrollo de comorbilidades,como la neuropatía autonómica cardiovascular. Sin embargo, pocos estudios han correlacionado dichas alteracionescon el período pre diabetes, aunque existan indicios de que puedan estar presentes ya en esa fase. Objetivos:Demostrar una correlación, por medio de la variabilidad de la frecuencia cardiaca, entre las alteraciones del sistemanervioso autónomo, la pre diabetes y la DM. Métodos: Se estudiaron 40 pacientes, divididos en cuatro grupos:(A) control; (B) pre diabéticos; (C) portadores de diabetes mellitus tipo 2 controlados; y (D) portadores de DMtipo 2 no controlados. Los datos obtenidos en el Holter 24h fueron correlacionados con los niveles glucémicosde ayuno y hemoglobina glicada, además de datos clínicos, tales como: presión arterial, IMC y circunferenciaabdominal. Resultados: Se encontró asociación significativa al compararse el SDNN del grupo control conpacientes diabéticos controlados (p=0,026) y no controlados (p=0,022). Conclusiones: A partir de los resultadosencontrados, se puede sugerir, mediante los resultados hasta entonces obtenidos, que los pacientes diabéticospresentan disturbios en la modulación autonómica cardiaca, conforme descrito en la literatura, no encontrándosedisautonomía cardiaca significativa en pre diabéticos.


Assuntos
Humanos , Masculino , Adolescente , Idoso , Arritmias Cardíacas/prevenção & controle , Diabetes Mellitus/epidemiologia , Estado Pré-Diabético/epidemiologia , Frequência Cardíaca , Hiperglicemia/sangue , Prevalência
7.
RELAMPA, Rev. Lat.-Am. Marcapasso Arritm ; 24(4): 264-270, out.-dez. 2011. tab, graf
Artigo em Português | LILACS | ID: lil-610051

RESUMO

O algoritmo de estimulação ventricular mínima (EVM) do marcapasso (MP) de dupla-câmara permite uma estimulação cardíaca fisiológica. Questiona-se se a associação de um sítio alternativo de estimulação ventricular pode reduzir a incidência de arritmias supraventriculares em longo prazo, sobretudo a fibrilação atrial (FA) crônica. Objetivo: Comparar a densidade de arritmia atrial, a dimensão do átrio esquerdo e a qualidade de vida quando do sinergismo entre a EVM (por meio do "suporte ao ritmo intrínseco" -"Intrinsic Rhythm Support - IRS plus) e a estimulação em via de saída do ventriculo direito (VSVD) com a estimulação em VSVD com a estimulação em VSVD isolada em pacientes com doença do nó sinusal (DNS) e/ou bloqueio atrioventricular (BAV) incomplet0o. Metodologia: Cinquenta pacientes foram submetidos ao implante de MP de dupla-câmara com o referido algoritmo. O eletrodo atrial foi posicionado no septo do átrio direito (AD) e o ventricular, na VSVD. Os pacientes foram randomizados em dois grupos: o Grupo I, com IRSplus ligado nos primeiros 6 meses, IRSplus desligado nos 6 meses seguintes e novamente IRS plus ligado nos 12 meses subsequentes: e o Grupo II, na sequência oposta à do Grupo I. Aos 6, 12, 18 e 30 meses todos os pacientes foram submetidos às seguintes avaliações: 1. seguimento de telemetria do MP pra avaliação da densidade...


Assuntos
Humanos , Masculino , Feminino , Pessoa de Meia-Idade , Estimulação Cardíaca Artificial/métodos , Fibrilação Atrial/diagnóstico , Marca-Passo Artificial , Ecocardiografia/métodos , Ecocardiografia , Qualidade de Vida/psicologia
8.
Arq. bras. cardiol ; 88(1): 1-7, jan. 2007. tab, graf
Artigo em Português | LILACS | ID: lil-443635

RESUMO

OBJETIVO: Avaliar os efeitos da estimulação atrial otimizada (EAO) (estimulação duplo-sítio atrial, freqüência acima da intrínseca e algoritmo funcional específico) e uso de atenolol, na prevenção da fibrilação atrial (FA) recorrente. Desfecho primário: quantificar a taxa de episódios de FA. Desfechos secundários: qualidade de vida, avaliação de sintomas específicos cardiovasculares, taxa de internações hospitalares, taxa de cardioversões elétricas e farmacológicas e eventos cardíacos adversos. MÉTODOS: Vinte e sete pacientes com FA paroxística recorrente e doença do nó sinusal foram submetidos ao implante de marcapasso duplo-sítio atrial e ventricular e iniciaram com atenolol 100 mg/dia, a seguir foram randomizados em dois grupos, grupo I (3 meses iniciais com EAO e algoritmo especifico ligado e mais 3 com o mesmo desligado) e grupo II (seqüência inversa do grupo I). O modo de estimulação foi DDDR e após 3 meses, foram submetidos à avaliação clínica e eletrônica do sistema de estimulação - mudança automática de modo (AMS), Holter de 24 horas, ecocardiograma e questionário SF-36. Em seguida, foram cruzados e após 6 meses, nova avaliação. RESULTADOS: Pacientes com EAO, quando comparados ao grupo com algoritmo desligado, apresentaram menores taxas de: FA/semana (p<0,001), ativações do AMS (p<0,01), hospitalizações (p<0,001), cardioversões (p<0,001), além de melhores índices dos componentes físico e mental da qualidade de vida. CONCLUSÃO: A terapêutica híbrida, EAO associada ao uso de atenolol, reduziu a taxa de recorrência de FA e proporcionou melhora clínico funcional de pacientes com bradiarritmias sintomáticas.


OBJECTIVE: Evaluate the effects of optimized atrial stimulation - OAS (dual-site atrial pacing, heart rate above the intrinsic rate, and specific functional algorithm), and the use of atenolol in preventing recurrent atrial fibrillation (AF). Primary endpoint: to quantify the rate of AF episodes. Secondary endpoints: assessment of quality of life, specific cardiovascular symptoms, rate of hospital admissions, rate of electrical and pharmacological cardioversions, and adverse cardiac events. METHODS: Twenty-five patients with recurrent episodes of paroxysmal AF and sinus node disease had dual-site atrial and ventricular pacemakers implanted, and were started on atenolol, 100 mg/day. Next, they were randomized to two groups: GROUP I: first three months with OAS and the specific pacing algorithm (DAO) turned on, and three more months with the algorithm off. GROUP II: the inverse sequence to GROUP I. The pacing mode chosen was DDDR, and after three months patients underwent clinical and electronic evaluations of the stimulation system by: automatic mode switch (AMS), 24-hour Holter monitoring, Doppler echocardiogram, and SF-36 questionnaire. Following, a crossover comparison took place, and a new assessment was performed six months later. RESULTS: When compared to the group with the algorithm turned off, OAS patients had lower rates of: AF/week (p < 0.001); AMS activations (p < 0.01); hospitalizations (p < 0.001); cardioversions (p < 0.001), and higher scores on the physical and mental components of quality of life. CONCLUSION: The hybrid therapy adopted, OAS associated with the use of atenolol, reduced the rate of recurrent AF and improved the clinical-functional status of patients with symptomatic bradyarrhythmias.


Assuntos
Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Antiarrítmicos/uso terapêutico , Atenolol/uso terapêutico , Fibrilação Atrial/prevenção & controle , Estimulação Cardíaca Artificial , Síndrome do Nó Sinusal/terapia , Algoritmos , Terapia Combinada , Estudos Cross-Over , Cardioversão Elétrica , Seguimentos , Estudos Prospectivos , Qualidade de Vida , Recidiva/prevenção & controle , Método Simples-Cego , Fatores de Tempo
9.
Rev. bras. cir. cardiovasc ; 13(4): 340-50, out.-dez. 1998. ilus
Artigo em Português | LILACS | ID: lil-229775

RESUMO

Introduction: The treatment of AV conduction disorders associated with sinus node illness employing DDDR pacemakers, has motivated the surch for an ideal sensor. Objective: Evaluate the heart rate response of the contractility sensor pacemaker both during the physical effort and mental stress of daily life in out patient tests for patients with bradycardia and chronotropic incompetence. Material and Methods: We use the brazilian Multicentric Study "Inos DR Project - Brazil" working with a DDDR stimulation system which uses the myocardial contractility state chronotropic 38 patients presenting; incompetence were selected, 21 men and 17 women, with age ranging from 13 to 83 years (mean 57 years). The pacemaker utilizes intrinsic cardiovascular information (cardiac contractility from the measure of the unipolar cardiac impedance) for heart rate adaptation, in a closed loop system that theoretically adjusts to all physiologic needs. The system calibration and programation were performed 30 days after implantation (stabilization of heart-lead interface), based on the tests of mental stress (mathematical) and treadmill test, monitoring heart rate histogram of frequency and oxygen consumption. Results: The acute stimulation threshold mean is 0.82 volts and 0.55 volts, and the mean sensibility is 2.37 mV and 10.61 mV, to atrium and ventricle respectively. The mean chronic stimulation threshold is 1.44 V and 1.18, and the mean sensibility threshold mean is 2.81 mV and 6 mV, to atrium and ventricle respectively. The heart rate varied from 5 per cent to 128 per cent on physical activity and from 5 per cent to 80 per cent on mental activity, with elevation right at the beginning of activity, permitting a normal oxygen consumption curve similar to that of normal person of the same age, sex and weight. The average data were compared using T Student test and the variables using variance analysis. Conclusion: The cardiac contractility sensor has an excelent performance on heart rate adaptation, with similar values produced by the autonomous nervous system of normal subjects.


Assuntos
Humanos , Masculino , Feminino , Adolescente , Adulto , Pessoa de Meia-Idade , Contração Miocárdica , Marca-Passo Artificial , Idoso de 80 Anos ou mais , Cardiografia de Impedância , Teste de Esforço , Frequência Cardíaca/fisiologia , Estudos Multicêntricos como Assunto , Limiar Sensorial
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA