Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 11 de 11
Filtrar
Mais filtros







Base de dados
Intervalo de ano de publicação
1.
Rev. bras. cir. cardiovasc ; 33(4): 362-370, July-Aug. 2018. tab, graf
Artigo em Inglês | LILACS | ID: biblio-958425

RESUMO

Abstract Objective: To analyze the behavior of platelets after transcatheter valve-in-valve implantation for the treatment of degenerated bioprosthesis and how they correlate with adverse events upon follow-up. Methods: Retrospective analysis of 28 patients who received a valve-in-valve implant, 5 in aortic, 18 in mitral and 5 in tricuspid positions. Data were compared with 74 patients submitted to conventional redo valvular replacements during the same period, and both groups' platelet curves were analyzed. Statistical analysis was conducted using the IBM SPSS Statistics(r) 20 for Windows. Results: All patients in the valve-in-valve group developed thrombocytopenia, 25% presenting mild (<150.000/µL), 54% moderate (<100.000/µL) and 21% severe (<50.000/µL) thrombocytopenia. The platelet nadir was on the 4th postoperative day for aortic ViV, 2nd for mitral and 3rd for tricuspid patients, with the majority of patients recovering regular platelet count. However, the aortic subgroup comparison between valve-in-valve and conventional surgery showed a statistically significant difference from the 7th day onwards, where valve-in-valve patients had more severe and longer lasting thrombocytopenia. This, however, did not translate into a higher postoperative risk. In our study population, postoperative thrombocytopenia did not correlate with greater occurrence of adverse outcomes and only normal preoperative platelet count could significantly predict a postoperative drop >50%. Conclusion: Although thrombocytopenia is an extremely common finding after valve-in-valve procedures, the degree of platelet count drop did not correlate with greater incidence of postoperative adverse outcomes in our study population.


Assuntos
Humanos , Masculino , Feminino , Adolescente , Adulto , Pessoa de Meia-Idade , Idoso , Idoso de 80 Anos ou mais , Adulto Jovem , Complicações Pós-Operatórias/etiologia , Complicações Pós-Operatórias/sangue , Trombocitopenia/etiologia , Trombocitopenia/sangue , Implante de Prótese de Valva Cardíaca/efeitos adversos , Contagem de Plaquetas/métodos , Valores de Referência , Reoperação , Fatores de Tempo , Valva Tricúspide/cirurgia , Bioprótese/efeitos adversos , Próteses Valvulares Cardíacas/efeitos adversos , Valor Preditivo dos Testes , Estudos Retrospectivos , Fatores de Risco , Resultado do Tratamento , Estatísticas não Paramétricas , Medição de Risco , Implante de Prótese de Valva Cardíaca/métodos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Valva Mitral/cirurgia
3.
Rev. bras. cir. cardiovasc ; 28(2): 217-223, abr.-jun. 2013. ilus
Artigo em Português | LILACS | ID: lil-682432

RESUMO

OBJETIVO: A insuficiência cardíaca é uma das causas mais comuns de internação. Dispositivos para assistência circulatória crônica foram testados e, em sua maioria, são de alta complexidade. O objetivo deste estudo é a descrição de uma endoprótese contrátil com capacidade de pulsação crônica no interior da aorta descendente, de maneira semelhante à produzida pelo balão intra-aórtico. MÉTODOS: Endopróteses pulsáteis compostas de níquel-titânio foram posicionadas de forma a envolver tubos de látex, simulando a aorta. Diferentes correntes elétricas foram aplicadas a unidades ligadas em série, de modo a causar contração da estrutura e deslocamento de uma coluna líquida. Foram realizadas duas sequências de testes: a primeira com duas gaiolas metálicas e a segunda com cinco gaiolas. Na primeira sequência de testes, aplicou-se tensão de 16,3 volts e corrente de 5 amperes e, na segunda sequência, tensão de 15 volts e corrente de 7 amperes. RESULTADOS: Na primeira sequência de testes, obteve-se o efeito pulsátil dos 2 stents, havendo contração do tubo e deslocamento da coluna d'água suficientes para validar o efeito pulsátil da endoprótese. As duas estruturas ejetaram um volume de 2,6 mL por ciclo, com uma variação de 29 mm na altura da coluna de água, equivalente a 8% de contração durante a pulsação. Na segunda sequência, conseguiu-se uma variação de 7,4 mL por ciclo. CONCLUSÃO: Os resultados obtidos comprovam a contratilidade da endoprótese pulsátil ativada pela aplicação de corrente elétrica. Continuidade do estudo e aperfeiçoamento do material se fazem necessários para obtenção de modelo mais eficiente do ponto de vista energético e com maior pulsação, para permitir volumes de ejeção comparáveis aos de balões intra-aórticos.


OBJECTIVE: Heart failure is currently one of the most common hospitalization causes. Several chronic circulatory assist devices have been tested and are highly complex. The objective is the description of a pulsatile endoprosthesis capable of applying a chronic pulse within the descending aorta, similar to that produced by intra-aortic balloon. METHODS: Pulsatile stents composed of nickel-titanium were built and positioned to engage latex tubes simulating the aorta. Different electric currents were applied to units connected in series in order to cause structure contraction and displacement of a liquid column. There were two sequence tests: first composed of two metallic cages and the second composed of five cages. At first sequence tests was applied a voltage of 16.3 volts and a current of 5 amperes. In the second, voltage of 15 volts and current of 07 amperes. RESULTS: In the first sequence was obtained the pulsatile effect of stent, with contraction of the tube and displacement of the water column sufficient to validate the pulsating effect of the endoprosthesis. The two structures ejected a volume of 2.6 ml per cycle, with a range of 29 mm in height of the column of water equivalent to 8% shrinkage during the pulse. In the second sequence, it reachead a variation of 7.4 mL per cycle. CONCLUSION: The results obtained confirm the stent pulsatile contractility activated by electrical current. The continuity of the study and material improvement are necessary to obtain more efficient model from the point of view of energy and pulse, to allow ejection volumes comparable with the intra-aortic balloons.


Assuntos
Humanos , Coração Auxiliar , Insuficiência Cardíaca/terapia , Fluxo Pulsátil , Desenho de Prótese/métodos , Stents , Aorta , Ventrículos do Coração , Ilustração Médica , Níquel/uso terapêutico , Reprodutibilidade dos Testes , Titânio/uso terapêutico
4.
Rev. bras. cir. cardiovasc ; 27(3): 355-361, jul.-set. 2012. ilus, tab
Artigo em Português | LILACS | ID: lil-660805

RESUMO

INTRODUÇÃO: A reoperação para substituição de biopróteses aórticas com disfunção é procedimento que envolve considerável risco. Em alguns casos, a mortalidade é elevada e pode contraindicar o procedimento. O implante minimamente invasivo "valve-in-valve" transcateter de valva aórtica parece ser uma alternativa, reduzindo morbimortalidade. O objetivo deste estudo foi avaliar esses implantes utilizando a prótese Braile Inovare. MÉTODOS: A prótese Braile Inovare, transcateter, balão expansível foi utilizada em 14 casos. Euroscore médio foi de 42,9%. Todos os pacientes eram portadores de dupla disfunção de bioprótese aórtica. Os procedimentos foram realizados em ambiente cirúrgico híbrido, sob controle ecocardiográfico e fluoroscópico. Por meio de minitoracotomia esquerda, as próteses foram implantadas através do ápice ventricular, sob estimulação ventricular de alta frequência. Foram realizados controles clínicos e ecocardiográficos seriados. O seguimento variou de 1 a 30 meses. RESULTADOS: A correta liberação protética foi possível em todos os casos. Não ocorreu conversão. Não houve mortalidade operatória. A mortalidade em 30 dias foi de 14,3% (dois casos). A fração de ejeção apresentou aumento significativo após o 7º pós-operatório e o gradiente aórtico apresentou redução significativa. A insuficiência aórtica residual não esteve presente. Não ocorreu complicação vascular periférica ou bloqueio atrioventricular total. CONCLUSÕES: O implante "valve-in-valve" de valva aórtica transcateter em biopróteses com disfunção é um procedimento seguro e com morbimortalidade baixa. Essa possibilidade poderá alterar a indicação de seleção de prótese no procedimento inicial, favorecendo próteses biológicas.


OBJECTIVE: Aortic valve replacement for bioprosthesis dysfunction is a procedure involving considerable risk. In some cases, mortality is high and may contraindicate the procedure. Minimally invasive transcatheter aortic "valve-in-valve" implant appears to be an alternative, reducing morbidity and mortality. The objective is to evaluate aortic valve-in-valve procedure using Braile Inovare prosthesis. METHODS: The Braile Inovare prosthesis, transcatheter, expandable balloon, was used in 14 cases. Average EuroSCORE was 42.9%. All patients had double aortic bioprosthesis dysfunction. Procedures were performed in a surgical hybrid environment under echocardiographic and fluoroscopic guidance. Using left minithoracotomy prostheses were implanted through the ventricular apex under high-frequency ventricular pacing. Serial clinical and echocardiographic controls were performed. Follow-up ranged 1-30 months. RESULTS: Correct prosthetic deployment was obtained in all cases. There was no conversion. There was no operative mortality. The 30-day mortality was 14.3% (two cases). Ejection fraction increased significantly after the 7th postoperative day. Aortic gradient significantly reduced. The residual aortic regurgitation was not present. There were no vascular complications or complete atrioventricular block. CONCLUSION: The transcatheter "valve-in-valve" procedure for bioprosthesis dysfunction is safe with low morbidity. This possibility may change prosthesis choice during the first aortic valve replacement, favoring bioprostheses.


Assuntos
Idoso , Feminino , Humanos , Masculino , Estenose da Valva Aórtica/cirurgia , Bioprótese , Cateterismo Cardíaco/métodos , Próteses Valvulares Cardíacas , Implante de Prótese de Valva Cardíaca/métodos , Estenose da Valva Aórtica/mortalidade , Cateterismo Cardíaco/mortalidade , Implante de Prótese de Valva Cardíaca/mortalidade , Estimativa de Kaplan-Meier , Reprodutibilidade dos Testes , Medição de Risco , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento
5.
Rev. bras. cir. cardiovasc ; 26(3): 338-347, jul.-set. 2011.
Artigo em Português | LILACS | ID: lil-624514

RESUMO

OBJETIVO: A troca valvar aórtica é procedimento rotineiro com risco aceitável. Em alguns casos, a mortalidade é elevada, contraindicando o procedimento. O implante minimamente invasivo transcateter de valva aórtica parece ser alternativa, reduzindo a morbimortalidade. A avaliação dos resultados clínicos, segurança e eficácia do procedimento são o objetivo desse estudo. MÉTODOS: Uma prótese transcateter, balão expansível foi utilizada em 33 casos de alto risco. EuroScore médio foi de 39,30% e STS score de 30,28%. Oito pacientes apresentavam disfunção de bioprótese e o restante, estenose aórtica calcificada. Os procedimentos foram realizados em ambiente cirúrgico híbrido, sob controle ecocardiográfico e fluoroscópico. Através de minitoracotomia esquerda, as próteses foram implantadas pelo ápice ventricular, sob estimulação de alta frequência ou choque hemorrágico. Foram realizados controles clínicos e ecocardiográficos. RESULTADOS: A correta liberação da prótese foi possível em 30 casos. Três conversões ocorreram. A mortalidade operatória foi de um caso e a mortalidade em 30 dias, 18,18%. O gradiente médio reduziu de 43,58 para 10,54 mmHg. A fração de ejeção apresentou aumento significativo após o 7º pós-operatório. Insuficiência aórtica residual esteve presente em 30,30% dos pacientes. Ocorreu uma complicação vascular periférica e um caso de bloqueio atrioventricular total. Um paciente apresentou acidente vascular cerebral. A mortalidade em 30 dias foi de 18,18%. CONCLUSÃO: O implante transapical de valva aórtica transcateter é procedimento seguro e com resultados de médio prazo satisfatórios. São necessários estudos de longo prazo com maior poder amostral no intuito de determinar resultado hemodinâmico, qualidade de vida e sobrevida em longo prazo.


OBJECTIVE: Aortic valve replacement is a routine procedure with acceptable risk, but in some cases, such risk can justify contraindication. Minimally invasive transcatheter aortic valve implantation has emerged as an alternative, with lower morbidity and mortality. The aim of this study was clinical, safety and efficacy assessment. METHODS: Thirty-three high risk patients underwent transcatheter balloon expandable aortic valve implantation. Mean Logistic EuroScore risk was 39.30% and STS score 30.28%. Eight patients presented with dysfunctional bioprosthesis, remaining ones presented calcified aortic stenosis. Procedures were performed in a hybrid OR under fluoroscopic and echocardiography guidance. Using a left minithoracotomy the prosthesis were implanted trough the ventricular apex under rapid ventricular pacing or hemorrhagic shock. Echocardiographic and angiographic controls were performed. RESULTS: Implant was feasible in 30 cases. Three conversions occured. There was only one case of operative death. Median transvalvular aortic gradient reduced from 43.58 mmHg to 10.54 mmHg. Left ventricular function improved in the first 7 postoperative days. Paravalvular aortic regurgitation was mild and present in 30.30%. One case presented major vascular complication and another one permanent pacemaker implant. One major stroke case occurred. Overall 30-day mortality was 18.18%. CONCLUSION: The transapical implantation of catheter mounted bioprosthesis is a safe procedure with acceptable midterm results. Long term follow-up with increased sample power is mandatory in order to access hemodynamic, life quality and survival.


Assuntos
Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estenose da Valva Aórtica/cirurgia , Valva Aórtica/cirurgia , Calcinose/cirurgia , Cateterismo Cardíaco/efeitos adversos , Implante de Prótese de Valva Cardíaca/métodos , Estenose da Valva Aórtica/fisiopatologia , Brasil , Calcinose/fisiopatologia , Estudos de Viabilidade , Cateterismo Cardíaco/métodos , Implante de Prótese de Valva Cardíaca/mortalidade , Estimativa de Kaplan-Meier , Medição de Risco/métodos , Resultado do Tratamento
6.
Clinics ; 66(12): 2049-2053, 2011. tab
Artigo em Inglês | LILACS | ID: lil-609001

RESUMO

OBJECTIVES: Patients with coronary artery disease and left ventricular dysfunction have high mortality when kept in clinical treatment. Coronary artery bypass grafting can improve survival and the quality of life. Recently, revascularization without cardiopulmonary bypass has been presented as a viable alternative. The aim of this study is to compare patients with left ventricular ejection fractions of less than 20 percent who underwent coronary artery bypass graft with or without cardiopulmonary bypass. METHODS: From January 2001 to December 2005, 217 nonrandomized, consecutive, and nonselected patients with an ejection fraction less than or equal to 20 percent underwent coronary artery bypass graft surgery with (112) or without (off-pump) (105) the use of cardiopulmonary bypass. We studied demographic, operative, and postoperative data. RESULTS: There were no demographic differences between groups. The outcome variables showed similar graft numbers in both groups. Mortality was 12.5 percent in the cardiopulmonary bypass group and 3.8 percent in the off-pump group. Postoperative complications were statistically different (cardiopulmonary bypass versus off-pump): total length of hospital stay (days)-11.3 vs. 7.2, length of ICU stay (days)-3.7 vs. 2.1, pulmonary complications-10.7 percent vs. 2.8 percent, intubation time (hours)-22 vs. 10, postoperative bleeding (mL)-654 vs. 440, acute renal failure-8.9 percent vs. 1.9 percent and left-ventricle ejection fraction before discharge-22 percent vs. 29 percent. CONCLUSION: Coronary artery bypass grafting without cardiopulmonary bypass in selected patients with severe left ventricular dysfunction is valid and safe and promotes less mortality and morbidity compared with conventional operations.


Assuntos
Idoso , Feminino , Humanos , Masculino , Ponte de Artéria Coronária sem Circulação Extracorpórea/métodos , Disfunção Ventricular Esquerda/cirurgia , Ponte de Artéria Coronária sem Circulação Extracorpórea/efeitos adversos , Índice de Gravidade de Doença , Resultado do Tratamento , Disfunção Ventricular Esquerda/fisiopatologia
7.
Rev. bras. cir. cardiovasc ; 25(3): 293-302, jul.-set. 2010. ilus, tab
Artigo em Português | LILACS | ID: lil-564994

RESUMO

OBJETIVO: A troca valvar aórtica é procedimento rotineiro com risco aceitável. Em alguns casos, a mortalidade é elevada, levando à contraindicação do procedimento, apesar dos sintomas. O implante minimamente invasivo transcateter de valva aórtica parece ser uma alternativa, reduzindo a morbi-mortalidade. O objetivo deste estudo foi o desenvolvimento e implante de nova prótese para implante transcateter. MÉTODOS: Após desenvolvimento em animais, uma prótese transcateter, balão-expansível foi utilizada em 14 casos de alto risco. O EuroSCORE médio foi de 43,7 por cento. Quatro pacientes apresentavam disfunção de biopróteses e o restante, estenose aórtica calcificada. Todos os pacientes eram sintomáticos. Os procedimentos foram realizados em ambiente cirúrgico híbrido, sob controle ecocardiográfico e fluoroscópico. Com o uso de minitoracotomia esquerda, as próteses foram implantadas através do ápice ventricular, sob estimulação ventricular de alta frequência ou choque hemorrágico controlado, após valvoplastia aórtica. Foram realizados controles clínicos e ecocardiográficos seriados. RESULTADOS: A correta liberação da prótese foi possível em 13 casos. Uma conversão ocorreu. Não houve mortalidade operatória. O gradiente de pico médio pós-implante foi de 25 mmHg. A fração de ejeção apresentou aumento significativo após o 7º pós-operatório. Insuficiência aórtica residual não significativa esteve presente em 71 por cento dos casos, nenhuma significativa. Não ocorreu complicação vascular periférica. Não houve necessidade de marcapasso definitivo. Um caso de acidente vascular cerebral ocorreu. A mortalidade geral foi de 42 por cento. CONCLUSÃO: O implante transapical de valva aórtica transcateter é um procedimento possível com esta nova prótese. O comportamento hemodinâmico foi satisfatório. São necessários estudos de longo prazo e com maior poder amostral, no intuito de determinar a real eficácia e indicação do procedimento alternativo.


OBJECTIVE: The aortic valve replacement is a routine procedure with acceptable risk, but in some cases, such a risk can justify contraindication. The minimally invasive transcatheter aortic valve implantation has been viable, with lower morbidity and mortality. The aim of this study was to develop a national catheter-mounted aortic bioprosthesis for the aortic position implant. METHODS: After animal studies, 14 patients with high EuroSCORE underwent transcatheter aortic valve implantation. Median Logistic EuroSCORE was 43.7 percent. Four patients presented with dysfunctional bioprosthesis, remaining ones presented calcified aortic stenosis. All patients presented symptoms. Procedures were performed in a hybrid OR under fluoroscopic and echocardiography guidance. Using a left minithoracotomy the prosthesis was implanted through the ventricular apex under ventricular pacing or hemorrhagic shock, after aortic valvoplasty. Echocardiograph and angiograph controls were performed, and the patients were referred to ICU. RESULTS: Implant was feasible in 13 cases. There were no intra-operative deaths. Median peak transvalvular aortic gradient reduced to 25.0 mmHg, and left ventricular function improved in the first seven post-operative days. Paravalvular aortic regurgitation was mild and present in 71 percent. No definitive pacemaker was needed. There was no peripheral vascular complication. Overall mortality was 42 percent. CONCLUSION: The transapical implantation of cathetermounted bioprosthesis was a feasible procedure. Long term follow-up is mandatory in order to access efficacy and indications.


Assuntos
Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estenose da Valva Aórtica/cirurgia , Implante de Prótese de Valva Cardíaca/métodos , Toracotomia/métodos , Aortografia , Cateterismo Cardíaco/métodos , Implante de Prótese de Valva Cardíaca/mortalidade , Resultado do Tratamento
8.
Rev. bras. cir. cardiovasc ; 24(2): 233-238, abr.-jun. 2009. ilus
Artigo em Inglês, Português | LILACS | ID: lil-525563

RESUMO

OBJETIVO: A troca valvar aórtica é procedimento rotineiro, envolve substituição da valva nativa/prótese. Na maioria destes pacientes o risco é aceitável, porém, em alguns casos, o risco predito pode justificar contra-indicação. O implante de valva aórtica minimamente invasivo transcateter e sem circulação extracorpórea (CEC) tem se mostrado viável, com menor morbi-mortalidade. O objetivo deste trabalho foi desenvolver bioprótese aórtica, montada em cateter, para implante sem CEC. MÉTODOS: Após desenvolvimento em animais, três pacientes com EuroSCORE elevado foram submetidos ao implante. Caso 1: portador de bioprótese com disfunção; Caso 2: estenose aórtica grave; Caso 3: disfunção de bioprótese aórtica. Após minitoracotomia e sob controle ecocardiográfico e fluoroscópico, cateter-balão foi posicionado sobre posição aórtica e insuflado. Após, segundo cateter-balão, com endoprótese valvada, foi posicionado e liberado sob alta frequência ventricular. Controles angiográficos e ecocardiográficos foram realizados e pacientes encaminhados para UTI. RESULTADOS: No primeiro caso foi possível implante sem CEC com resultados adequados. Evoluiu com melhora da função ventricular. Cursou com broncopneumonia, fístula traqueo-esofágica e óbito por mediastinite. Necropsia confirmou bom posicionamento valvar e preservação dos folhetos. O segundo caso apresentou migração do dispositivo após insuflação do balão, necessidade de esternotomia mediana de urgência, CEC e troca valvar convencional. O paciente evoluiu bem, recebendo alta da UTI 14 dias após procedimento e sem complicações. Cursou com infecção respiratória, choque séptico e óbito no 60º pós-operatório. O terceiro caso foi submetido a implante com sucesso. CONCLUSÃO: O implante de bioprótese transapical montada em cateter sem CEC mostrou ser procedimento factível. Detalhes técnicos e a curva de aprendizado demandam discussão.


OBJECTIVE: The aortic valve replacement is a routine procedure, and involves replacement of the native valve/prosthesis. In most of the patients who undergo such procedure the risk is acceptable, but in some cases, such risk can justify contraindication. The minimally invasive transcatheter aortic valve implantation without cardiopulmonary bypass (CPB) has been shown to be viable, with lower morbidity and mortality. The aim of this study was to develop a catheter-mounted aortic bioprosthesis for implantation without CPB. METHODS: After developing in animals, three patients with high EuroSCORE underwent implantation. Case 1: patients with bioprosthesis dysfunction; Case 2: severe aortic stenosis; Case 3: dysfunction of aortic bioprosthesis. After minithoracotomy and under echocardiographic and fluoroscopic control, a balloon catheter was placed on aortic position and inflated. After, a second balloon with valved endoprosthesis was positioned and released under high ventricular rate. Echocardiographic and angiographic controls were performed and the patients were referred to ICU. RESULTS: In the first case, implantation without CPB was possible with appropriate results. The patient evolved with improvement of ventricular function. After, this patient developed bronchopneumonia, tracheoesophageal fistula and died due to mediastinitis. Autopsy confirmed proper valve positioning and leaflets preservation. The second case showed the device migration after inflation of the balloon, with the need for urgent median sternotomy, CPB and conventional valve replacement. This patient evolved well and was discharged from the ICU on the 14th postoperative day without complications. This patient developed respiratory infection, septic shock and died on the 60th postoperative day. The patient from the third case underwent successful implantation. CONCLUSION: The off-pump transapical implantation of catheter-mounted bioprosthesis was shown to be a feasible ...


Assuntos
Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estenose da Valva Aórtica/terapia , Valva Aórtica/cirurgia , Bioprótese , /instrumentação , Próteses Valvulares Cardíacas , Implante de Prótese de Valva Cardíaca/métodos , Ponte Cardiopulmonar , Evolução Fatal , Implante de Prótese de Valva Cardíaca/efeitos adversos , Desenho de Prótese , Falha de Prótese , Reoperação , Medição de Risco
9.
Rev. bras. cir. cardiovasc ; 16(1): 1-6, jan.-mar. 2001. graf, tab
Artigo em Português | LILACS | ID: lil-289375

RESUMO

Introduçäo: A revascularizaçäo do miocárdio sem circulaçäo extracorpórea (CEC) é hoje alternativa de revascularizaçäo em expansäo näo estando ainda bem definidos os limites de sua aplicabilidade. Os autores revêem sua casuística global e discutem as indicaçöes ideais do procedimento baseados nos resultados obtidos. Casuística e Métodos: Säo analisados 2.495 pacientes operados sem CEC de outubro de 1981 a setembro de 1999 de um total de 10.656 pacientes revascularizados no período (23,4 por cento). As idades variaram de 32 a 90 anos, mediana 59, e o sexo masculino predominou (67 por cento). Insuficiência coronária crônica foi responsável por 70,8 por cento das indicaçöes operatórias e a maioria dos pacientes recebeu 2 pontes (51,5 por cento). Resultados: A mortalidade (30 dias) global foi de 1,9 por cento (48/2495) e a morbidade referente a eventos maiores foi significativamente menor em um subgrupo deste material que foi prospectivamente. Apenas 45 por cento dos operados necessitaram de transfusäo sangüínea contrastando com 90,5 por cento dos operados com a técnica convencional. A aplicabilidade da técnica que no global foi de 23 por cento nos últimos três anos foi de 36,8 por cento, 35, l por cento e 42,2 por cento. Conclusäo: A revascularizaçäo do miocárdio sem CEC é alternativa segura de tratamento da insuficiência coronária observando-se um aumento progressivo de sua aplicaçäo nos últimos anos. Permite o tratamento de um subgrupo de pacientes com baixa mortalidade hospitalar e menor incidência de complicaçöes pós-operatórias, devendo seu uso ser expandido nos próximos anos com a introduçäo dos estabilizadores, manobras especiais e a revascularizaçäo funcional


Assuntos
Humanos , Masculino , Feminino , Adulto , Pessoa de Meia-Idade , Baixo Débito Cardíaco/cirurgia , Circulação Extracorpórea , Revascularização Miocárdica/métodos , Idoso de 80 Anos ou mais , Procedimentos Cirúrgicos Minimamente Invasivos , Resultado do Tratamento
10.
Rev. bras. cir. cardiovasc ; 12(4): 372-6, out.-dez. 1997. ilus
Artigo em Português | LILACS | ID: lil-209413

RESUMO

Este trabalho tem como objetivo a apresentaçäo do caso de uma paciente submetida à correçäo da dissecçäo da aorta descendente utilizando "stent" recoberto com Dacron introduzido através da artéria femoral na sala de hemodinâmica. Para este fim, a paciente foi submetida a sedaçäo, anestesia local de ambas regiöes inguinais e heparinizaçäo sistêmica. O cateter contendo o "stent" foi introduzido através da artéria femoral comum esquerda previamente dissecada até a aorta descendente no seu terço médio. A expansäo do "stent" foi realizada no local onde existia a lesäo da íntima diagnosticada previamente por arteriografia, com oclusäo imediata da falsa luz. O tempo do procedimento foi de 1h30 min. A alta hospitalar ocorreu, sem complicaçöes, 48 horas após o procedimento. Acreditamos que este procedimento poderá proporcionar uma melhora substancial nos resultados do tratamento das dissecçöes da aorta descendente.


Assuntos
Humanos , Feminino , Idoso , Aneurisma Aórtico/cirurgia , Dissecção Aórtica/cirurgia , Stents , Artéria Femoral/cirurgia , Resultado do Tratamento
11.
Rev. bras. cir. cardiovasc ; 11(4): 227-31, out.-dez. 1996. tab
Artigo em Português | LILACS | ID: lil-184571

RESUMO

A revascularizaçao miocárdica sem circulaçao extracorpórea agora se constitui numa alternativa de tratamento cirúrgico de cardiopatia isquêmica de interesse crescente. O objetivo deste trabalho é apresentar os resultados obtidos ao longo de 15 anos de experiência ininterrupta. De setembro de l981 a março de 1996, 1549 pacientes foram operados sem o auxílio do coraçao-pulmao artificial, o que constitui cerca de 18 por cento do total de pacientes operados no período. As idades variaram de 28 a 86 anos, oscilando em torno de 57 anos, sendo l126 do sexo masculino e 423 do feminino. O número de pontes variou de l a 5, com média de 1,7 pontes/paciente. A técnica nao constituiu problema especial para o emprego de enxertos arteriais, sendo as artérias torácicas internas utilizadas em 1140 artérias coronárias. Em 1515 pacientes a via de acesso foi a esternotomia mediana e, em 34, a toracotomia anterior esquerda mínima. A mortalidade operatória global foi de 2,4 por cento (38/1549), sendo a principal causa o mau débito cardíaco em pacientes operados em isquemia aguda, sendo 8 sob auxílio de balao intra-aórtico. Os resultados desta experiência permitem concluir que a revascularizaçao do miocárdio sem circulaçao extracorpórea é uma excelente alternativa de revascularizaçao para determinado subgrupo de pacientes, oferecendo baixa mortalidade e morbidade pós-operatória, sendo especialmente indicada em pacientes com complicaçoes clínicas pré-existentes e de maior risco operatório.


Assuntos
Humanos , Masculino , Feminino , Adulto , Pessoa de Meia-Idade , Circulação Extracorpórea , Isquemia Miocárdica/cirurgia , Revascularização Miocárdica/métodos , Idoso de 80 Anos ou mais , Circulação Extracorpórea/efeitos adversos , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA