Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros







Base de dados
Intervalo de ano de publicação
1.
Rev. bras. cir. cardiovasc ; 36(3): 420-423, May-June 2021. tab, graf
Artigo em Inglês | LILACS | ID: biblio-1288239

RESUMO

Abstract In the growing era of transcatheter aortic valve implantation, it is crucial to develop minimally invasive surgical techniques. These methods enable easier recovery from surgical trauma, especially in elderly and frail patients. Minimally invasive aortic valve replacement (MIAVR) is frequently performed via upper hemisternotomy. We describe MIAVR via right anterior thoracotomy, which is associated with less trauma, rapid mobilization, lower blood transfusion rates, and lower risk of postoperative wound infections. As minimally invasive procedures tend to take longer operative times, we suggest using rapid-deployment valve prostheses to overcome this limitation. This description focuses on the technical aspects and preoperative assessment.


Assuntos
Humanos , Idoso , Estenose da Valva Aórtica/cirurgia , Próteses Valvulares Cardíacas , Implante de Prótese de Valva Cardíaca , Valva Aórtica/cirurgia , Toracotomia , Estudos Retrospectivos , Resultado do Tratamento
2.
Rev. bras. cir. cardiovasc ; 35(4): 411-419, July-Aug. 2020. tab, graf
Artigo em Inglês | LILACS, SES-SP | ID: biblio-1137311

RESUMO

Abstract Introduction: People with aortic/prosthetic valve endocarditis are a high-risk cohort of patients who present a challenge for all medically involved disciplines and who can be treated by various surgical techniques. Methods: We analyzed the results of treatment of root endocarditis with Medtronic Freestyle® in full-root technique over 19 years (1999-2018) and compared them against treatment with other tissue valves. Comparison was made with propensity score matching, using the nearest neighbor method. Various tests were performed as suited for adequate analyses. Results: Fifty-four patients in the Medtronic Freestyle group (FS group) were matched against 54 complex root endocarditis patients treated with other tissue valves (Tissue group). Hospital mortality was 9/54 (16.7%) in the FS group vs. 14/54 (25.6%) in the Tissue group (P=0.24). Cox regression performed for early results demonstrated coronary heart disease (P=0.004, odds ratio 2.3), among others, influencing early mortality. Recurrent infection was low (1.8% for FS and Tissue patients) and freedom from reoperation was 97.2% at a total of 367 patient-years of follow-up (median of 2.7 years). Conclusion: The stentless xenograft is a viable alternative for treatment of valve/root/prosthetic endocarditis, demonstrating a low rate of reinfection. The design of the bioroot allows for complex reconstructive procedures at the outflow tract and the annular level with at an acceptable operative risk. Endocarditis patients can be treated excluding infective tissue from the bloodstream, possibly with benefits, concerning bacteremia and recurrent infection. Furthermore, the use of the stentless bioroot offers varying treatment options in case of future valve degeneration.


Assuntos
Humanos , Masculino , Feminino , Pessoa de Meia-Idade , Idoso , Bioprótese/efeitos adversos , Próteses Valvulares Cardíacas/efeitos adversos , Implante de Prótese de Valva Cardíaca/efeitos adversos , Endocardite Bacteriana/cirurgia , Valva Aórtica/cirurgia , Desenho de Prótese , Reoperação , Resultado do Tratamento , Pontuação de Propensão
3.
Rev. bras. cir. cardiovasc ; 35(3): 241-248, May-June 2020. tab, graf
Artigo em Inglês | LILACS, SES-SP | ID: biblio-1137266

RESUMO

Abstract Objective: To determine the feasibility of aortic valve neocuspidization (AVNeo) with glutaraldehyde-treated autologous pericardium. Methods: One hundred and seventy (170) AVNeo (84 males/86 females) were performed from January 2017 through March 2019 in three centers. All the records were prospectively collected and retrospectively reviewed. Results: Most of the patients were older than 60 years and over 95% were operated for aortic stenosis. Preoperatively, pressure gradients were 69.9±21.3 mmHg for patients with aortic stenosis, and the surgical annular diameter was 21.0±2.0 mm for all patients. Effective orifice area (EOA) and indexed EOA (iEOA) averaged 0.7±0.3 cm2 and 0.4±0.2 cm2/m2 for patients with aortic stenosis before surgery, respectively. There was no conversion to prosthetic aortic valve replacement. Eight patients needed reoperation for bleeding, but no patient needed reoperation due to early infective endocarditis. There were five in-hospital deaths due to noncardiac cause. Compared to preoperative echocardiographic measurements, postoperative peak pressure gradient decreased significantly (-58.7±1.7 mmHg; P<0.001) and reached 11.2±5.6 mmHg, and mean pressure gradient also decreased significantly (-36.8±1.1 mmHg; P<0.001) and reached 6.0±3.5 mmHg. Accordingly, EOA and iEOA increased significantly 2.0 cm2 and 1.0 cm2/m2 (both P<0.001) to reach 2.7±0.6 cm2 and 1.4±0.3 cm2/m2 after surgery, respectively, with minimal significant aortic regurgitation (0.6% > mild). Conclusion: AVNeo is feasible and reproducible with good clinical results. Hemodynamically, AVNeo produces immediate postoperative low-pressure gradients, large EOA, and minimal regurgitation of the aortic valve. Further studies are necessary to evaluate mid- and long-term evolution.


Assuntos
Humanos , Masculino , Feminino , Pessoa de Meia-Idade , Idoso , Estenose da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Bioprótese , Próteses Valvulares Cardíacas , Implante de Prótese de Valva Cardíaca , Valva Aórtica/cirurgia , Valva Aórtica/diagnóstico por imagem , Pericárdio/transplante , Estudos Retrospectivos , Resultado do Tratamento , Glutaral
4.
Rev. bras. cir. cardiovasc ; 35(2): 141-144, 2020. tab, graf
Artigo em Inglês | LILACS | ID: biblio-1101481

RESUMO

Abstract Objective: To test the German Aortic Valve (GAV) score at our university hospital in patients undergoing isolated aortic valve replacement (AVR). Methods: A total of 224 patients who underwent isolated conventional AVR between January 2015 and December 2018 were included. Patients with concomitant procedures and transcatheter aortic valve implantation were excluded. Patients' data were collected and analyzed retrospectively. Patients' risk scores were calculated according to criteria described by GAV score. Sensitivity, specificity, and accuracy (area under the ROC curve [AUC]) were also calculated. The calibration of the model was tested by the Hosmer-Lemeshow method. Results: The mortality rate was 8.04% (18 patients). The patients' mean age was 58.2±19.3 years and 25% of them were female (56 patients). Mean GAV score was 1.73±5.86 (min: 0.0; max: 3.53). The GAV score showed excellent discriminative capacity (AUC 0.925, 95% confidence interval 0.882-0.956; P<0.001). The cutoff "1.8" turned out to be the best discriminatory point with the best combination of sensitivity (88.9%) and specificity (75.7%) to predict operative death. Hosmer-Lemeshow method revealed a P-value of 0.687, confirming a good calibration of the model. Conclusion: The GAV score applies to our population with high predictive accuracy.


Assuntos
Humanos , Masculino , Feminino , Adulto , Pessoa de Meia-Idade , Idoso , Implante de Prótese de Valva Cardíaca , Valva Aórtica , Estenose da Valva Aórtica , Brasil , Estudos Retrospectivos , Fatores de Risco , Resultado do Tratamento , Medição de Risco
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA