Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Mais filtros







Base de dados
Indicadores
Intervalo de ano de publicação
1.
Arq. bras. oftalmol ; 83(2): 141-145, Mar.-Apr. 2020. tab, graf
Artigo em Inglês | LILACS | ID: biblio-1088976

RESUMO

ABSTRACT Purpose: To compare the postoperative refractive predictability of IOLMaster 500 and Pentacam HR on the basis of keratometry and anterior chamber depth values in eyes with an indication for multifocal intraocular lens (IOL) implantation. Methods: This was a retrospective study conducted on 118 eyes treated with phacoemulsification and multifocal intraocular lens implantation. Only the eyes that achieved emmetropia in the dynamic refraction performed on postoperative day 30 were included. Haigis' formula was used in each case to calculate the intraocular lens power, and the intraocular lens with the target refraction closest to emmetropia was implanted. Four lens calculation scenarios were tested by combining keratometry and anterior chamber depth measurements obtained using the two devices. Results: IOLMaster 500 and Pentacam HR differed with regard to mean keratometry (D 0.07 ± 0.03 D; p=0.0065) and anterior chamber depth (D 0.08 ± 0.01 mm; p<0.001). In the analysis of covariance, the following differences were obtained using the Haigis' formula when confronted with the biometric values obtained by inserting keratometry and anterior chamber depth values, respectively: Penta/IOL x IOL/Penta (0.13 ± 0.03; p<0.0001); Penta/Penta × IOL/Penta (0.13 ± 0.03; p<0.0001); Penta/IOL × IOL/IOL (0.11 ± 0.03; p=0.001); Penta/Penta × IOL/IOL (0.11 ± 0.03; p=0.002); IOL/IOL × IOL/Penta (0.02 ± 0.03; p=0.865); and Penta/IOL × Penta/Penta (0.002 ± 0.03; p=0.99). The difference was smaller when measuring the anterior chamber depth using the IOLMaster 500, regardless of which device was used to measure keratometry. Conclusions: Pentacam HR significantly differed from IOLMaster 500 when calculating keratometry. As regards the anterior chamber depth, the two devices were equally accurate.


RESUMO Objetivo: Comparar a previsibilidade refrativa pós-operatória do IOLMaster 500 e Pentacam HR com base nos valores de ceratometria e profundidade de câmara anterior nos olhos com indicação de implante de lentes intraoculares multifocais. Métodos: Estudo retrospectivo realizado em 118 olhos tratados com facoemulsificação e implante de lentes intraoculares multifocal. Apenas os olhos que atingiram a emetropia na refração dinâmica no 30º dia pós-operatório foram incluídos. A fórmula de Haigis foi usada em cada caso para calcular o poder das lentes intraoculares, e a lente intraocular com a refração alvo mais próxima da emetropia foi implantada. Cenários de cálculo de quatro lentes foram testados pela combinação de medidas de ceratometria e profundidade de câmara anterior obtidas usando os dois dispositivos. Resultados: IOLMaster 500 e Pentacam HR diferiram quanto à média de ceratometria (D 0,07 ± 0,03 D; p=0,0065) e profundidade de câmara anterior (D 0,08 ± 0,01 mm; p<0,001). Na análise da covariância, as seguintes diferenças foram obtidas usando a fórmula de Haigis quando confrontadas com os valores biométricos obtidos pela inserção dos valores de ceratometria e profundidade de câmara anterior, respectivamente: Penta/IOL x IOL/Penta (0,13 ± 0,03; p<0,0001); Penta/Penta x IOL/Penta (0,13 ± 0,03; p<0,0001); Penta/IOL x IOL/IOL (0,11 ± 0,03; p=0,001); Penta/Penta x IOL/IOL (0,11 ± 0,03; p=0,002); IOL/IOL x IOL/Penta (0,02 ± 0,03; p=0,865); Penta/IOL x Penta/Penta (0,002 ± 0,03; p=0,99). A diferença foi menor ao medir a profundidade da câmara anterior usando o IOLMaster 500, independentemente de qual dispositivo foi usado para medir a ceratometria. Conclusões: O Pentacam HR diferiu significativamente do IOLMaster 500 no cálculo de ceratometria. Quanto à profundidade da câmara anterior, os dois dispositivos foram igualmente precisos.


Assuntos
Humanos , Masculino , Feminino , Pessoa de Meia-Idade , Idoso , Facoemulsificação/métodos , Córnea/patologia , Topografia da Córnea/instrumentação , Implante de Lente Intraocular/métodos , Lentes Intraoculares Multifocais , Câmara Anterior/patologia , Período Pós-Operatório , Valores de Referência , Refração Ocular/fisiologia , Fatores de Tempo , Acuidade Visual/fisiologia , Valor Preditivo dos Testes , Estudos Retrospectivos , Biometria , Resultado do Tratamento , Córnea/diagnóstico por imagem , Interferometria/instrumentação , Interferometria/métodos , Câmara Anterior/diagnóstico por imagem
2.
Rev. bras. oftalmol ; 77(4): 184-188, jul.-ago. 2018. tab, graf
Artigo em Inglês | LILACS | ID: biblio-959100

RESUMO

ABSTRACT Objective: To evaluate the correlation of optical biometry and target with variable ages, anterior chamber depth, axial length, R1/K1 and R2/K2 established by two optical biometry devices in patients with cataract. Methods: The study included the analysis of 348 medical records, from which 503 cataract eyes were selected, which underwent evaluation by the optical biometric devices IOL Master 700 and Lenstar LS 900 in the period of April to July 2017. Data collected were: age, anterior chamber depth, axial length, R1/K1 and R2/K2. Results: The average of the biometrics obtained using Lenstar was 21.02, varying 3.46, more or less, with an average target of -0.02, varying 0.45. In relation to the IOL Master it was 21.19, with a variation of 3.40 and average target of -0.01, a variation of 0.11. It can be observed that despite close values in relation to the mean, there was significance (p<0.001). Axial length (p<0.001) and R1/K1 (p<0.001) had an influence on the difference of the biometric values between the devices. Conclusion: A high degree of clinical and statistical correspondence was observed between the results obtained by the biometry devices in patients with cataract.


RESUMO Objetivos: Avaliar a correlação da biometria óptica e target com as variáveis idade, profundidade da câmara anterior, comprimento axial, R1/K1 e R2/K2 estabelecidos por dois dispositivos de biometria óptica em pacientes com catarata. Métodos: O trabalho abrangeu a análise de 348 prontuários dos quais foram selecionados 503 olhos com catarata ,que passaram pela avaliação nos dispositivos de biometria óptica IOL Master 700 e Lenstar LS 900 no período de abril a julho de 2017. Os dados colhidos foram: idade, profundidade da câmara anterior, comprimento axial, R1/K1 e R2/K2 . Resultados: A média da biometria obtida utilizando o Lenstar foi de 21,02, variando 3,46 para mais ou para menos, com target médio de -0,02, variando 0,45. Já em relação ao IOL Master foi de 21,19, com variação de 3,40 e target médio de -0,01, variação de 0,11. Pode-se observar que apesar de valores próximos em relação à média, houve significância (p < 0,001). Houve a concordância da biometria em relação ao comprimento axial (p < 0,001) e R1/K1(p < 0,001). Conclusão: Observou-se alto grau de correspondência clínica e estatística entre os resultados obtidos pelos dispositivos de biometria em pacientes com catarata.


Assuntos
Humanos , Masculino , Feminino , Adulto , Pessoa de Meia-Idade , Idoso , Idoso de 80 Anos ou mais , Erros de Refração/diagnóstico por imagem , Catarata/diagnóstico , Biometria/instrumentação , Biometria/métodos , Comprimento Axial do Olho/diagnóstico por imagem , Lentes Intraoculares/normas , Câmara Anterior/diagnóstico por imagem , Refração Ocular/fisiologia , Extração de Catarata/métodos , Acuidade Visual , Estudos Transversais , Reprodutibilidade dos Testes , Córnea/diagnóstico por imagem , Topografia da Córnea/instrumentação , Implante de Lente Intraocular/métodos , Período Pré-Operatório , Registros Eletrônicos de Saúde , Estudo Observacional , Cristalino/diagnóstico por imagem
3.
Rev. bras. oftalmol ; 74(6): 350-354, nov.-dez. 2015. tab, graf
Artigo em Inglês | LILACS | ID: lil-767072

RESUMO

RESUMO Objetivo: Avaliar os parâmetros biométricos oculares por meio da biometria óptica e observar uma possível diferença refratométrica esférica, assim como sua variação, baseada no cálculo pré-cirúrgico estimado e na refração esférica pós-cirurgia de catarata pela facoemulsificação com implante de lente intraocular (LIO). Métodos: Foram revisados 252 prontuários eletrônicos entre 2013 e 2014 dos quais foram selecionados 117 pacientes adultos (189 olhos) submetidos à facoemulsificação com implante de LIO dobrável pelo mesmo cirurgião e examinados através do IOLMaster® 500. O poder dióptrico da LIO foi calculado pela fórmula de Haigis. O teste de Wilcoxon foi empregado para testar a existência de diferença significativa (p<0,05) entre o grau esférico esperado (GEE) e o grau esférico final (GEF). Resultados: Foram operados 98 olhos direitos (OD) e 91 esquerdos (OE). Após calculada a variação entre o GEE e o GEF observou-se que 55% dos OD alcançaram resultados dentro de ± 0,5 dioptrias (D) e 89% resultados dentro de ± 1D. Quanto ao OE, 46% alcançaram resultados dentro de ± 0,5D e 78% dentro de ± 1D. Conclusão: A biometria óptica pode ser utilizada como um método confiável, previsível e reprodutível para que seja estimado o GEF de ambos olhos.


ABSTRACT Objective: To assess ocular biometric parameters by optical biometry and to observe a possible spherical refractive difference, as well as its variation based on estimated preoperative calculation and the spherical refraction post cataract surgery by phacoemulsification with intraocular lens implant (IOL). Methods: After reviewing 252 electronic medical records between 2013 and 2014, 117 adult patients (189 eyes) were selected.The patients underwent phacoemulsification with foldable IOL implantation by the same surgeon and were examined by IOLMaster® 500.The IOL power was calculated using the Haigis formula.The Wilcoxon test was applied to identify the existence of significant differences (p<0.05) between the spherical expected refraction (SER) and the final spherical refraction (FSR) of the eyes. Results: There were operated 98 right eyes (OD) and 91 left (OS). A calculation of the variation between FSR and SER indicated that 55% of the OD reached results within ± 0.5 diopters (D) and 89% within ± 1D. With respect to OS, 46% achieved results within ± 0.5D and 78% within ± 1D. Conclusion: Optical biometry is a reliable, predictable and reproducible method to estimate the FSR of both eyes.


Assuntos
Humanos , Masculino , Feminino , Adulto , Pessoa de Meia-Idade , Idoso , Idoso de 80 Anos ou mais , Biometria/instrumentação , Biometria/métodos , Facoemulsificação/métodos , Implante de Lente Intraocular/métodos , Comprimento Axial do Olho/anatomia & histologia , Refração Ocular/fisiologia , Extração de Catarata/métodos , Estudos Transversais , Valor Preditivo dos Testes , Reprodutibilidade dos Testes , Registros Eletrônicos de Saúde , Lentes Intraoculares
4.
Arq. bras. oftalmol ; 78(3): 180-184, May-Jun/2015. tab
Artigo em Inglês | LILACS | ID: lil-753016

RESUMO

ABSTRACT Purpose: To evaluate the difference in terms of refractive errors and anterior segment parameters between schizophrenic patients and healthy volunteers. Methods: This study compared 70 patients (48 men) who were diagnosed with schizophrenia with a control group of 60 (35 men) who were similar in terms of age, gender, education, and socioeconomic level. Anterior segment examination was performed using a Scheimflug system. Axial length and lens thickness (LT) were measured using optic biometry. The following tests were administered to the psychiatric patient group: Brief Psychiatric Rating Scale (BPRS), Scale for the Assessment of Negative Symptoms (SANS), and Scale for the Assessment of Positive Symptoms (SAPS). Results: Mild myopia was detected in both the schizophrenic and control groups, with no statistically significant difference (p>0.005). Corneal volume (CV), anterior chamber volume (ACV), anterior chamber depth (ACD), and central corneal thickness (CCT) values were lower in the schizophrenic group, and there was a statistically significant between-group difference (p=0.026, p=0.014, p=0.048, and p=0.005, respectively). LT was greater in schizophrenics, and the difference was found to be statistically significant (p=0.006). A statistically significant negative correlation was found between SAPS and cylinder values (p=0.008). The axial eye length, cylinder value, pupil diameter, mean keratometric value, and anterior chamber angle revealed no statistically significant difference between the groups (p>0.05). Conclusion: No statistically significant difference was detected in terms of refraction disorders between schizophrenics and the healthy control group, while some differences in anterior chamber parameters were present. These results demonstrate that schizophrenics may exhibit clinical and structural differences in the eye. .


RESUMO Objetivo: Avaliar se existem diferenças em relação aos erros refracionais e parâmetros do segmento anterior entre pacientes com esquizofrenia e voluntários saudáveis. Métodos: Este estudo comparou 70 pacientes diagnosticados com esquizofrenia (48 homens) com um grupo controle de 60 pacientes, semelhantes em relação à idade, sexo, escolaridade e nível socioeconômico (35 homens). O exame do segmento anterior foi realizado com o sistema Scheimflug; os comprimentos axiais do olho e a espessura do cristalino foram avaliadas por meio de biometria óptica. Os seguintes testes foram aplicados ao grupo de pacientes psiquiátricos: Brief Psychiatric Rating Scale (BPRS), Scale for the Assessment of Negative Symptoms (SANS), e Scale for the Assessment of Positive Symptoms (SAPS). Resultados: Miopia leve foi detectada em ambos os grupos de esquizofrenia e de controle, sem diferença estatisticamente significativa (p>0,005). Volume de córnea (CV), volume da câmara anterior (ACV), profundidade da câmara anterior (ACD) e paquimetria central da córnea (CCT) apresentaram valores menores no grupo de esquizofrênicos e houve diferença estatisticamente significativa entre os dois grupos (p=0,026, p=0,014, p=0,048 e p=0,005, respectivamente). A espessura do cristalino (LT) foi maior em esquizofrênicos e a diferença foi estatisticamente significativa (p=0,006). Foi encontrada uma correlação negativa estatisticamente significativa entre SAPS e os valores cilíndricos (p=0,008). O comprimento axial do olho, o valor do cilindro, o diâmetro pupilar, a ceratometria média e o ângulo da câmara anterior não revelaram nenhuma diferença estatística entre os grupos (p>0,05). Conclusões: Não foi detectada diferença estatisticamente significativa em relação aos transtornos de refração entre os esquizofrênicos e o grupo controle, enquanto algumas diferenças nos parâmetros de câmara anterior estavam presentes. Estes resultados demonstram que esquizofrénicos podem ...


Assuntos
Adulto , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Adulto Jovem , Segmento Anterior do Olho , Biometria/métodos , Erros de Refração , Esquizofrenia , Segmento Anterior do Olho/fisiopatologia , Comprimento Axial do Olho/patologia , Estudos Transversais , Córnea/anatomia & histologia , Cristalino/patologia , Miopia/complicações , Miopia/diagnóstico , Escalas de Graduação Psiquiátrica , Pupila/fisiologia , Erros de Refração/diagnóstico , Erros de Refração/fisiopatologia , Fatores Socioeconômicos , Inquéritos e Questionários , Esquizofrenia/tratamento farmacológico , Esquizofrenia/fisiopatologia , Fatores de Tempo
5.
Arq. bras. oftalmol ; 72(2): 189-193, mar.-abr. 2009. graf, tab
Artigo em Inglês | LILACS | ID: lil-513887

RESUMO

Purpose: To evaluate the prediction of refraction using the SRK/T formula for intraocular lens (IOL) calculation in eyes with medium axial length after phacoemulsification. Methods: This prospective study enrolled 33 eyes with nuclear cataract that underwent phacoemulsification. All procedures were performed by one surgeon with theintraocular lens placed within the capsular bag. The same technician whowas unaware of the purpose of the study made all the measurements. Theachieved refractive error one month after surgery was compared to the predicted postoperative refractive error by the SRK/T formula. Results: The ocular axial length varied between 22.2 mm and 24.5 mm. The mean predicted refraction was -0.431 ± 0.181 D and the mean achieved postoperative spherical equivalent was -0.220 ± 0.732 D. Eighteen eyes (55%) had a refractive error between ± 0.50 D and thirty eyes (91%) between ± 1.00 D of the predicted refraction. There was a tendency toward hyperopic shift (mean ± SD: 0.211 ± 0.708 D, p=0.009). Conclusion: The SRK/T formula demonstrated a satisfactory accuracy to calculate the error of refraction in eyes with medium axial length.


Objetivo: Avaliar resultados refracionais utilizando a fórmula SRK/T no cálculo de lentes intraoculares (LIO) em olhos comcomprimento axial médio após facoemulsificação. Métodos: Este estudo prospectivo envolveu 33 olhos com catarata nuclear que foram submetidos a facoemulsificação. Todas as cirurgias foram realizadas pelo mesmo cirurgião com lentes intraoculares no saco capsular. O mesmo tecnólogo, o qualnão sabia o objetivo do estudo, realizou todas as medidas biométricas. O erro refracional atingido um mês após a cirurgia foi comparado ao erro refracional pós-operatório previsto pelafórmula SRK/T. Resultados: O comprimento axial variou entre 22,2 mm e 24,5 mm. A refração média prevista foi -0,431 ± 0,181 dioptrias (D) e o equivalente esférico pós-operatório alcançado foi -0,220 ± 0,732 D. Dezoito olhos (55%) obtiveram errorefracional de ± 0,50 D e 30 olhos (91%) entre ± 1,00 D da refração prevista. Houve tendência a um erro hipermetrópico (média±SD: 0,211 ± 0,708 D, p=0,009). Conclusão: A fórmula SRK/T demonstrou acurácia satisfatória no cálculo do erro refracional em olhos de comprimento axial médio.


Assuntos
Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Implante de Lente Intraocular , Facoemulsificação/métodos , Valor Preditivo dos Testes , Estudos Prospectivos , Refratometria , Reprodutibilidade dos Testes , Resultado do Tratamento , Acuidade Visual
6.
Arq. bras. oftalmol ; 71(3): 389-393, maio-jun. 2008. tab
Artigo em Português | LILACS | ID: lil-486117

RESUMO

OBJETIVOS: Determinar a incidência do glaucoma agudo primário no Serviço de Glaucoma do Hospital São Geraldo; estabelecer o perfil destes pacientes e identificar possíveis fatores de risco. MÉTODOS: Estudo transversal. Período de análise: setembro/2005 a agosto/2006. Inclusão: diagnóstico de glaucoma agudo primário. Exclusão: presença de catarata que acarrete baixa acuidade visual ou miopização, glaucomas secundários, íris em platô. Foram avaliados: número de atendimentos, incidência de glaucoma agudo primário, idade, sexo, raça, história familiar de glaucoma, ceratometria, e dados biométricos. RESULTADOS: Dentre 879 pacientes atendidos, 20 (2,3 por cento) tiveram o diagnóstico de glaucoma agudo primário, desse modo, a incidência de glaucoma agudo primário foi de 22,7 por 1000 atendimentos. Dos pacientes com glaucoma agudo primário: 6 (30,0 por cento) eram do sexo masculino e 14 (70,0 por cento) feminino; a idade variou de 40 a 73 anos (média: 60,4 ± 8,1 anos); 12 (60,0 por cento) eram leucodérmicos e 8 (40,0 por cento) feodérmicos; 5 (25,0 por cento) com história familiar positiva para glaucoma. O risco relativo para o sexo feminino foi de 1,44 (IC 95 por cento). Onze (55,0 por cento) pacientes tiveram glaucoma agudo primário no olho direito e 9 (45,0 por cento) no esquerdo. Não houve diferença estatisticamente significativa na comparação dos parâmetros biométricos e ceratometria entre os olhos afetados e os contralaterais. CONCLUSÕES: A incidência de glaucoma agudo primário no Serviço de Glaucoma do Hospital São Geraldo foi de 22,7 por 1000 atendimentos, sendo mais freqüente em mulheres, leucodérmicas, com história familiar negativa para glaucoma e média de idade de 60,4 anos. Os olhos afetados e olhos contralaterais foram semelhantes nos parâmetros biométricos.


PURPOSE: To determine the incidence of the primary angle-closure glaucoma at the Glaucoma Service of São Geraldo Hospital, to establish the profile of these patients and to identify the possible risk factors. METHODS: Transversal study. Period of assessment: from September/2005 to August/2006. Inclusion criteria: diagnosis of primary angle-closure glaucoma. Exclusion criteria: presence of cataracts that cause low visual acuity or index-myopia, secondary glaucoma, plateau iris. Number of visits, incidence of primary angle-closure glaucoma, age, gender, race, family history of glaucoma, keratometric, and biometric data were assessed. RESULTS: Of 879 attended patients, 20 (2.3 percent) had the diagnosis of primary angle-closure glaucoma, therefore, the incidence of the primary angle-closure glaucoma was 22.7 cases per 1000 attended. Of those patients with primary angle-closure glaucoma: 6 (30.0 percent) were men and 14 (70.0 percent) women; the age varied from 40 to 73 years (average: 60.4 ± 8.1 years); 12 (60.0 percent) were leukodermics and 8 (40.0 percent) pheodermics; 5 (25.0 percent) with positive familiar history of glaucoma. The relative risk for women was 1.44 (95 percent IC). Eleven (55.0 percent) patients had primary angle-closure glaucoma of the right eye and 9 (45.0 percent) of the left. When biometric data and keratometry were compared between the affected and contralateral eye, no statistical significant difference was observed. CONCLUSIONS: The incidence of the primary angle-closure glaucoma at the Glaucoma Service of São Geraldo Hospital was 22.7 cases per 1000 attended. It was more frequent in leukodermic women, without family history of glaucoma and with an average age of 60.4 years. The affected and contralateral eyes were biometrically similar.


Assuntos
Adulto , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Glaucoma de Ângulo Fechado/epidemiologia , Brasil/epidemiologia , Estudos de Casos e Controles , Estudos Transversais , Grupos Raciais/estatística & dados numéricos , Características da Família , Glaucoma de Ângulo Fechado/etiologia , Hospitais , Incidência , Fatores de Risco
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA