Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 23
Filtrar
2.
Arq. bras. cardiol ; 113(6): 1104-1111, Dec. 2019. tab, graf
Artigo em Inglês | LILACS | ID: biblio-1055057

RESUMO

Abstract Background: Chronic kidney disease (CKD) is frequently present in patients with aortic valve disease. Decreased kidney perfusion as a consequence of reduced cardiac output may contribute to renal dysfunction in this setting. Objective: Given the potential reversibility of kidney hypoperfusion after valve repair, this study aimed to analyze the impact of percutaneous transcatheter aortic valve implantation (TAVI) on kidney function. Methods: We performed a retrospective analysis of 233 consecutive patients who underwent TAVI in a single center between November 2008 and May 2016. We assessed three groups according to their baseline estimated glomerular filtration rate (eGFR) (mL/min/1.73 m2): Group 1 with eGFR ≥ 60; Group 2 with 30 ≤ eGFR < 60; and Group 3 with eGFR < 30. We analyzed the eGFR one month and one year after TAVI in these three groups, using the Chronic Kidney Disease Epidemiology Collaboration (CKD-EPI) formula to calculate it. Results: Patients from Group 1 had a progressive decline in eGFR one year after the TAVI procedure (p < 0.001 vs. pre-TAVI). In Group 2 patients, the mean eGFR increased one month after TAVI and continued to grow after one year (p = 0.001 vs. pre-TAVI). The same occurred in Group 3, with the mean eGFR increasing from 24.4 ± 5.1 mL/min/1.73 m2 before TAVI to 38.4 ± 18.8 mL/min/1.73 m2 one year after TAVI (p = 0.012). Conclusions: For patients with moderate-to-severe CKD, kidney function improved one year after the TAVI procedure. This outcome is probably due to better kidney perfusion post-procedure. We believe that when evaluating patients that might need TAVI, this 'reversibility of CKD effect' should be considered.


Resumo Fundamento: Pacientes com doença valvar aórtica frequentemente apresentam doença renal crônica (DRC). Diminuição da perfusão renal como consequência da redução do débito cardíaco pode contribuir para a disfunção renal neste cenário. Objetivo: Dado o potencial de reversibilidade da hipoperfusão renal após o reparo valvar, este estudo teve o objetivo de analisar o impacto do implante percutâneo de válvula aórtica (TAVI - transcatheter aortic valve implantation) na função renal. Métodos: Foi realizada uma análise retrospectiva de 233 pacientes consecutivos submetidos ao TAVI em um único centro, entre novembro de 2008 e maio de 2016. Três grupos foram avaliados de acordo com a taxa de filtração glomerular estimada (TFGe) basal (mL/min/1,73 m2): Grupo 1 com TFGe ≥ 60; Grupo 2 com 30 ≤ TFGe < 60; e Grupo 3 com TFGe < 30. O TFGe foi analisado nestes três grupos um mês e um ano após o TAVI e calculado usando a fórmula do Chronic Kidney Disease Epidemiology Collaboration (CKD-EPI). Resultados: Os pacientes do Grupo 1 tiveram um declínio progressivo da TFGe um ano após o procedimento TAVI (p < 0,001 vs. pré-TAVI). Nos pacientes do Grupo 2, a média da TFGe aumentou um mês depois do TAVI e continuou crescendo depois de um ano (p = 0,001 vs. pré-TAVI). O mesmo ocorreu no Grupo 3, com a média da TFGe subindo de 24,4 ± 5,1 mL/min/1,73 m2 antes do TAVI para 38,4 ± 18,8 mL/min/1,73 m2 um ano após o TAVI (p = 0,012). Conclusões: Em pacientes com DRC moderada a grave, a função renal melhorou um ano após o procedimento TAVI. Este resultado é provavelmente devido à melhora da perfusão renal pós-procedimento. Acredita-se que, ao avaliar pacientes que possam precisar de TAVI, este 'efeito de reversibilidade da DRC' deva ser considerado.


Assuntos
Humanos , Masculino , Feminino , Pessoa de Meia-Idade , Idoso , Idoso de 80 Anos ou mais , Estenose da Valva Aórtica/cirurgia , Insuficiência Renal Crônica/reabilitação , Substituição da Valva Aórtica Transcateter/métodos , Estenose da Valva Aórtica/complicações , Comorbidade , Estudos Retrospectivos , Fatores de Risco , Insuficiência Renal Crônica/etiologia , Substituição da Valva Aórtica Transcateter/estatística & dados numéricos , Taxa de Filtração Glomerular
3.
Arq. bras. cardiol ; 106(6): 519-527, tab, graf
Artigo em Inglês | LILACS | ID: lil-787321

RESUMO

Abstract Background: Transcatheter aortic valve implantation has become an option for high-surgical-risk patients with aortic valve disease. Objective: To evaluate the in-hospital and one-year follow-up outcomes of transcatheter aortic valve implantation. Methods: Prospective cohort study of transcatheter aortic valve implantation cases from July 2009 to February 2015. Analysis of clinical and procedural variables, correlating them with in-hospital and one-year mortality. Results: A total of 136 patients with a mean age of 83 years (80-87) underwent heart valve implantation; of these, 49% were women, 131 (96.3%) had aortic stenosis, one (0.7%) had aortic regurgitation and four (2.9%) had prosthetic valve dysfunction. NYHA functional class was III or IV in 129 cases (94.8%). The baseline orifice area was 0.67 ± 0.17 cm2 and the mean left ventricular-aortic pressure gradient was 47.3±18.2 mmHg, with an STS score of 9.3% (4.8%-22.3%). The prostheses implanted were self-expanding in 97% of cases. Perioperative mortality was 1.5%; 30-day mortality, 5.9%; in-hospital mortality, 8.1%; and one-year mortality, 15.5%. Blood transfusion (relative risk of 54; p = 0.0003) and pulmonary arterial hypertension (relative risk of 5.3; p = 0.036) were predictive of in-hospital mortality. Peak C-reactive protein (relative risk of 1.8; p = 0.013) and blood transfusion (relative risk of 8.3; p = 0.0009) were predictive of 1-year mortality. At 30 days, 97% of patients were in NYHA functional class I/II; at one year, this figure reached 96%. Conclusion: Transcatheter aortic valve implantation was performed with a high success rate and low mortality. Blood transfusion was associated with higher in-hospital and one-year mortality. Peak C-reactive protein was associated with one-year mortality.


Resumo Fundamento: O implante de válvula aórtica por cateter tornou-se uma opção para pacientes com doença valvar aórtica de elevado risco cirúrgico. Objetivo: Avaliar os resultados dos seguimentos intra-hospitalar e de até 1 ano do implante de válvula aórtica por cateter. Métodos: Estudo de coorte prospectiva de casos de implante de válvula aórtica por cateter entre julho de 2009 e fevereiro de 2015. Análise de variáveis clínicas e do procedimento, correlacionando com mortalidade intra-hospitalar e de 1 ano. Resultados: Foram submetidos ao implante 136 pacientes, com média de idade de 83 (80-87) anos, sendo 49% mulheres, 131 (96,3%) deles com estenose aórtica, um (0,7%) com insuficiência aórtica e quatro (2,9%) com disfunção de prótese. A classe funcional da NYHA foi III ou IV em 129 (94,8%) casos. A área valvar inicial foi 0,67 ± 0,17 cm2 e o gradiente ventrículo esquerdo-aorta médio de 47,3 ± 18,2 mmHg, com STS de 9,3% (4,8%-22,3%). As próteses implantadas eram autoexpansíveis em 97% dos casos. A mortalidade peroperatória em 1,5% dos casos; em 30 dias em 5,9%; intra-hospitalar em 8,1%; e após 1 ano em 15,5% dos casos. A hemotransfusão (risco relativo de 54; p = 0,0003) e a hipertensão arterial pulmonar (risco relativo de 5,3; p = 0,036) foram preditoras de mortalidade hospitalar; e a proteína C-reativa pico (risco relativo de 1,8; p = 0,013) e a hemotransfusão (risco relativo de 8,3; p = 0,0009) de mortalidade em 1 ano. Aos 30 dias, 97% dos pacientes estavam em classe NYHA I/II e, em 1 ano, o número chegou a 96%. Conclusão: O implante de válvula aórtica por cateter foi realizado com alto índice de sucesso e baixa mortalidade. A hemotransfusão associou-se com maior mortalidade hospitalar e de 1 ano. Proteína C-reativa pico se associou com a mortalidade de 1 ano.


Assuntos
Humanos , Masculino , Feminino , Idoso de 80 Anos ou mais , Valva Aórtica/cirurgia , Insuficiência da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/cirurgia , Mortalidade Hospitalar , Substituição da Valva Aórtica Transcateter/mortalidade , Insuficiência da Valva Aórtica/epidemiologia , Estenose da Valva Aórtica/epidemiologia , Complicações Pós-Operatórias/mortalidade , Fatores de Tempo , Brasil/epidemiologia , Métodos Epidemiológicos
4.
Rev. Assoc. Med. Bras. (1992) ; 62(1): 32-37, Jan.-Feb. 2016. tab, graf
Artigo em Inglês | LILACS | ID: lil-777440

RESUMO

SUMMARY Introduction: the EuroSCORE II and STS are the most used scores for surgical risk stratification and indication of transcatheter aortic valve implantation (TAVI). However, its role as a tool for mortality prediction in patients undergoing TAVI is still unclear. Objective: to evaluate the performance of the EuroSCORE II and STS as predictors of in-hospital and 30-day mortality in patients undergoing TAVI. Methods: we included 59 symptomatic patients with severe aortic stenosis that underwent TAVI between 2010 and 2014. The variables were analyzed using Student's t-test and Fisher's exact test and the discriminative power was evaluated using receiver operating characteristic curve (ROC) and area under the curve (AUC) with a 95% confidence interval. Results: mean age was 81±7.3 years, 42.3% men. The mean EuroSCORE II was 7.6±7.3 % and STS was 20.7±10.3%. Transfemoral procedure was performed in 88.13%, transapical in 3.38% and transaortic in 8.47%. In-hospital mortality was 10.1% and 30-day mortality was 13.5%. Patients who died had EuroSCORE II and STS higher than the survivors (33.7±16.7vs. 18.6±7.3% p=0,0001 for STS and 13.9±16.1 vs. 4.8±3.8% p=0.0007 for EuroSCORE II). The STS showed an AUC of 0.81 and the EuroSCORE II of 0.77 and there were no differences in the discrimination ability using ROC curves (p=0.72). Conclusion: in this cohort, the STS and EuroSCORE II were predictors of in-hospital and 30-days mortality in patients with severe aortic stenosis undergoing TAVI.


RESUMO Introdução: STS e EuroSCORE II são os escores mais utilizados para a estratificação de risco cirúrgico e indicação do implante de válvula aórtica transcateter (TAVI). Entretanto, seu papel como ferramenta para predição de mortalidade em pacientes submetidos ao TAVI ainda é incerto. Objetivo: avaliar o desempenho do EuroSCORE II e STS como preditores de mortalidade intra-hospitalar em 30 dias em pacientes submetidos ao TAVI. Métodos: 59 pacientes com estenose aórtica importante submetidos ao TAVI entre 2010 e 2014. Variáveis foram analisadas por meio do teste t-Student e teste exato de Fisher, e o poder discriminativo foi avaliado pela curva ROC e área sob a curva, acompanhada de intervalo de confiança de 95%. Resultados: a idade média foi de 81±7,3 anos, 42,3% homens. Média do EuroSCORE II foi de 6,07±7,3%, e do STS, 20,7±10,3%. Procedimento transfemoral foi realizado em 88,13%, transapical, em 3,38% e transaórtico, em 8,47%. A mortalidade intra-hospitalar foi 10,1%, e em 30 dias, 13,5%. Os pacientes que evoluíram para óbito apresentavam STS e EuroSCORE II mais elevados que os sobreviventes (33,7±16,7% vs. 18,6±7,3%; p=0,0001 para STS e 13,9±16,1% vs. 4,8±3,8%; p=0,0007 para EuroSCORE II). O STS apresentou AUC de 0,81, e o EuroSCORE II, 0,77. Não houve diferença na capacidade de discriminação pelas curvas ROC (p=0,72). Conclusão: STS e EuroSCORE II foram preditores de mortalidade intra-hospitalar em 30 dias.


Assuntos
Humanos , Masculino , Feminino , Idoso , Idoso de 80 Anos ou mais , Medição de Risco/métodos , Substituição da Valva Aórtica Transcateter/mortalidade , Estenose da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/mortalidade , Brasil , Reprodutibilidade dos Testes , Estudos Retrospectivos , Fatores de Risco , Sensibilidade e Especificidade , Mortalidade Hospitalar , Substituição da Valva Aórtica Transcateter/efeitos adversos
5.
Rev. bras. cardiol. invasiva ; 23(4): 238-241, out.-dez. 2015. tab, graf
Artigo em Português | LILACS | ID: biblio-846502

RESUMO

Introdução: A válvula aórtica transcateter de segunda geração LotusTM foi desenhada para proporcionar ao intervencionista o controle completo de sua liberação durante o procedimento. O presente estudo apresenta a experiência inicial e os desfechos hospitalares de pacientes tratados com essa prótese no Brasil. Métodos: Registro observacional, retrospectivo, que incluiu pacientes com estenose aórtica grave sintomáticos, considerados de alto risco cirúrgico, tratados em sete centros.Resultados: Receberam o dispositivo 31 pacientes, sendo 61,3% do sexo feminino, com idade de 82,9 ± 6,9 anos e escore STS de 6,5 ± 4,1%. A área valvar aórtica foi de 0,73 ± 0,18 cm2 e o gradiente médio de 51,7 ± 13,9 mmHg. Todos os procedimentos foram realizados pela via transfemoral, e a pré-dilatação foi necessária em 65% dos casos. A taxa de sucesso do procedimento foi de 96,7%. Não houve complicação vascular com necessidade de intervenção cirúrgica e nem casos de acidente vascular cerebral. O gradiente médio após o procedimento foi de 10,5 ± 5,8 mmHg e não foram observadas regurgitações aórticas de graus moderado/importante. A taxa de implante de marca-passo definitivo foi de 38,7%, e a permanência hospitalar de 8,5 ± 4,8 dias. Conclusões: Na experiência inicial com o implante da válvula aórtica LotusTM, os resultados hospitalares demostraram a segurança e a eficácia do dispositivo, além de ausência de regurgitação aórtica relevante


Background: The second-generation LotusTM transcatheter aortic valve was designed to provide the interventional cardiologist with complete control of its release during the procedure. This study presents the initial experience and in-hospital outcomes of patients treated with this prosthesis in Brazil. Methods: This observational and retrospective study included patients with symptomatic severe aortic stenosis considered at high surgical risk, treated in seven centers. Results: The device was used in 31 patients, 61.3% female, aged 82.9 ± 6.9 years, and with STS score of 6.5 ± 4.1%. The aortic valve area was 0.73 ± 0.18 cm2 and the mean gradient was 51.7 ± 13.9 mmHg. All procedures were performed by the transfemoral access route, and pre-dilation was necessary in 65% of cases. The success rate of the procedure was 96.7%. There were no vascular complications requiring surgical intervention nor cases of stroke. The mean gradient after the procedure was 10.5 ± 5.8 mmHg; no cases of moderate to severe aortic regurgitation were observed. The rate of permanent pacemaker implantation was 38.7%, and mean in-hospital length of stay was 8.5 ± 4.8 days. Conclusions: In the initial experience with the use of the LotusTM aortic valve, in-hospital results demonstrated the safety and efficacy of the device; no cases of significant aortic regurgitation were observed


Assuntos
Humanos , Masculino , Feminino , Idoso , Valva Aórtica/cirurgia , Próteses e Implantes , Desfibriladores Implantáveis , Estenose da Valva Aórtica/terapia , Bioprótese/tendências , Fatores de Risco , Estudo Observacional , Insuficiência Cardíaca/terapia , Valvas Cardíacas/cirurgia , Ventrículos do Coração/fisiopatologia
6.
Arq. bras. cardiol ; 105(3): 241-247, Sept. 2015. ilus, tab
Artigo em Inglês | LILACS, SES-SP, SESSP-IDPCPROD, SES-SP | ID: lil-761513

RESUMO

AbstractBackground:Predicting mortality in patients undergoing transcatheter aortic valve implantation (TAVI) remains a challenge.Objectives:To evaluate the performance of 5 risk scores for cardiac surgery in predicting the 30-day mortality among patients of the Brazilian Registry of TAVI.Methods:The Brazilian Multicenter Registry prospectively enrolled 418 patients undergoing TAVI in 18 centers between 2008 and 2013. The 30-day mortality risk was calculated using the following surgical scores: the logistic EuroSCORE I (ESI), EuroSCORE II (ESII), Society of Thoracic Surgeons (STS) score, Ambler score (AS) and Guaragna score (GS). The performance of the risk scores was evaluated in terms of their calibration (Hosmer–Lemeshow test) and discrimination [area under the receiver–operating characteristic curve (AUC)].Results:The mean age was 81.5 ± 7.7 years. The CoreValve (Medtronic) was used in 86.1% of the cohort, and the transfemoral approach was used in 96.2%. The observed 30-day mortality was 9.1%. The 30-day mortality predicted by the scores was as follows: ESI, 20.2 ± 13.8%; ESII, 6.5 ± 13.8%; STS score, 14.7 ± 4.4%; AS, 7.0 ± 3.8%; GS, 17.3 ± 10.8%. Using AUC, none of the tested scores could accurately predict the 30-day mortality. AUC for the scores was as follows: 0.58 [95% confidence interval (CI): 0.49 to 0.68, p = 0.09] for ESI; 0.54 (95% CI: 0.44 to 0.64, p = 0.42) for ESII; 0.57 (95% CI: 0.47 to 0.67, p = 0.16) for AS; 0.48 (95% IC: 0.38 to 0.57, p = 0.68) for STS score; and 0.52 (95% CI: 0.42 to 0.62, p = 0.64) for GS. The Hosmer–Lemeshow test indicated acceptable calibration for all scores (p > 0.05).Conclusions:In this real world Brazilian registry, the surgical risk scores were inaccurate in predicting mortality after TAVI. Risk models specifically developed for TAVI are required.


ResumoFundamento:Ainda é desafiador prever a mortalidade de pacientes que se submetem ao TAVI (sigla do inglês Transcatheter Aortic Valve Implantation).Objetivos:Avaliar o desempenho de cinco escores de risco para cirurgia cardíaca em prever mortalidade em 30 dias de pacientes inscritos no Registro Brasileiro de TAVI.Métodos:O Registro Multicêntrico Brasileiro inscreveu prospectivamente 418 pacientes submetidos ao TAVI em 18 centros entre 2008 e 2013. Os seguintes escores cirúrgicos foram usados para calcular o risco de mortalidade no período de 30 dias: EuroSCORE I (ESI) logístico, EuroSCORE II (ESII), STS Score (STS), Ambler Score (AS) e Guaragna Score (GS). O desempenho dos escores de risco foram avaliados através de sua calibração (teste Hosmer-Lemeshow) e discriminação [área sob a curva (AUC) do inglês receiver-operating characteristic curve)].Resultados:A idade média foi de 81,5 ± 7,7 anos. A prótese aórtica CoreValve (Medtronic) foi usada em 86,1% da coorte e a abordagem transfemural usada em 96,2%. A mortalidade observada no período de 30 dias foi de 9,1%. A mortalidade no período de 30 dias prevista pelos escores foi: ESI, 20,2 ± 13,8%; ESII, 6,5 ± 13,8%; STS, 14,7 ± 4,4%; AS, 7,0 ± 3,8%; GS, 17,3 ± 10,8%. Nenhum dos escores testados com a AUC foi capaz de prever a mortalidade no período de 30 dias de forma precisa. As AUC para os escores foram: 0,58 [95% de intervalo de confiança (IC): 0,49 a 0,68, p = 0,09] para ESI; 0,54 (IC de 95%: 0,44 a 0,64, p = 0,42) para ESII; 0,57 (IC de 95%: 0,47 a 0,67, p = 0,16) para AS; 0,48 (IC de 95%: 0,38 a 0,57, p = 0,68) para STS e 0,52 (IC de 95%: 0,42 a 0,62, p = 0,64) para GS. O teste Hosmer-Lemeshow indicou uma calibração aceitável para todos os escores (p > 0,05).Conclusões:Neste registro brasileiro de mundo real, os escores de risco cirúrgico foram imprecisos para prever a mortalidade após o TAVI. São necessários modelos de risco desenvolvidos especificamente para o TAVI.


Assuntos
Humanos , Masculino , Feminino , Idoso , Idoso de 80 Anos ou mais , Medição de Risco/métodos , Substituição da Valva Aórtica Transcateter/mortalidade , Estenose da Valva Aórtica/mortalidade , Estenose da Valva Aórtica/cirurgia , Brasil , Calibragem , Métodos Epidemiológicos , Valores de Referência , Reprodutibilidade dos Testes , Fatores de Tempo
7.
Rev. SOBECC ; 20(3): 134-142, jul.-set. 2015. tab
Artigo em Português | LILACS, BDENF | ID: lil-779387

RESUMO

Estenose aórtica (EAo) é a doença cardíaca valvar mais comum, afeta, aproximadamente, 3% da população idosa submetida a implante de bioprótese aórtica por cateter. Os enfermeiros necessitam aperfeiçoar o conhecimento para elaborar protocolos de atendimento e cuidados. Objetivo: propor intervenções de enfermagem no período pós-operatório imediato para pacientes submetidos a tratamento da estenose aórtica por cateter. Método: pesquisa retrospectiva, quantitativa, com amostra composta por 418 pacientes cujos dados foram fornecidos pelo Registro Brasileiro de Implante por Cateter de Biotrótese Valvar Aórtica, entre janeiro de 2008 e fevereiro de 2013. Resultados: a média de idade foi de 81,5 anos, 348 pacientes apresentavam classe funcional III ou IV de insuficiência cardíaca, sendo que as complicações com maior incidência foram: bloqueio de ramo esquerdo (129 pacientes), bloqueio átrio ventricular (110) e necessidade de implante de marca-passo (83). Conclusão: Foram propostas as intervenções de enfermagem para avaliação da função neurológica, vascular, hematológica, renal, cardíaca, parâmetros vitais e controle da dor...


Assuntos
Humanos , Idoso de 80 Anos ou mais , Bioprótese , Cuidados Pós-Operatórios/enfermagem , Cuidados de Enfermagem , Estenose da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/enfermagem , Saúde do Idoso
8.
Rev. bras. cir. cardiovasc ; 30(4): 425-432, July-Aug. 2015. tab, graf
Artigo em Inglês | LILACS | ID: lil-763158

RESUMO

AbstractObjective:The aim of the current study was to evaluate the early experience of the application of transcatheter aortic valve implantation with the balloon-expandable system in China. The transcatheter aortic valve implantation technology has been widely used for patients with inoperable severe aortic stenosis in the developed world. The application of transcatheter aortic valve implantation is still in the early stages of testing in China, particularly for the balloon-expandable valve procedure.Methods:This was a retrospective study. All patients undergoing transcatheter aortic valve implantation with balloon-expandable system in our hospital between 2011 and 2014 were included. Edwards SAPIEN XT Transcatheter Heart Valve was used. The improvement of valve and heart function was evaluated as well as 30-day mortality and major complications according to the VARC-2 definition.Results:A total of 10 transcatheter aortic valve implantation procedures with the balloon-expandable system were performed in our hospital, of which 9 were transfemoral and 1 was transapical. The median age was 76 years, and the median STS score and Logistic EuroSCORE (%) were 8.9 and 16.2. The implantation was successfully conducted in all patients, only 2 patients had mild paravalvular leak. There was no second valve implantation. Moreover, no 30-day mortality or complications was reported. Following the transcatheter aortic valve implantation procedure, the heart and valve functions had improved significantly. During the follow-up period of 3-34 months, one patient died of lung cancer 13 months after the operation.Conclusion:This early experience has provided preliminary evidence for the safety and efficacy of transcatheter aortic valve implantation procedure with the balloon-expandable system in the developing world with an increasing aging population.


ResumoObjetivo:O objetivo do presente estudo foi avaliar a experiência inicial da aplicação do implante percutâneo da válvula aórtica com o sistema balão-expansível na China. A tecnologia TAVI tem sido amplamente utilizada para pacientes com estenose aórtica grave inoperável no mundo desenvolvido. A aplicação de implante percutâneo da válvula aórtica está ainda nas etapas iniciais de teste na China, em particular o procedimento de válvula balão-expansível.Métodos:O estudo foi retrospectivo e todos os pacientes submetidos a implante percutâneo da válvula aórtica com sistema balão-expansível em nosso hospital entre 2011 e 2014 foram incluídos. Edwards SAPIEN XT Válvula Cardíaca Transcatheter foi usado. A melhoria do funcionamento da válvula e do coração foi avaliada, bem como mortalidade em 30 dias e as principais complicações de acordo com a definição VARC-2.Resultados:Um total de 10 procedimentos Tavi com o sistema balão-expansível foram realizados em nosso hospital, dos quais 9 foram transfemorais e 1 foi transapical. A idade média foi de 76 anos, e os STS mediana marcar e Logistic EuroSCORE (%) foram de 8,9 e 16,2. A implantação foi realizada com sucesso em todos os pacientes, apenas 2 pacientes tiveram vazamento paravalvar leve. Não houve um futuro implante valvar. Além disso, mortalidade em 30 dias ou complicações não foram relatadas. Seguindo o procedimento de implante percutâneo da válvula aórtica, as válvulas cardíacas e funções melhoraram significativamente. Durante o período de acompanhamento de 3-34 meses, um paciente morreu de câncer de pulmão 13 meses após a operação.Conclusão:Esta experiência inicial apresentou elementos de prova preliminar para a segurança e eficácia do procedimento implante percutâneo da válvula aórtica com o sistema balão-expansível no mundo em desenvolvimento com crescente envelhecimento da população.


Assuntos
Idoso , Feminino , Humanos , Masculino , Estenose da Valva Aórtica/terapia , Valvuloplastia com Balão/métodos , Substituição da Valva Aórtica Transcateter/métodos , Angiografia , Estenose da Valva Aórtica , China/epidemiologia , Estudos Retrospectivos , Resultado do Tratamento , Substituição da Valva Aórtica Transcateter/instrumentação , Substituição da Valva Aórtica Transcateter/mortalidade
9.
Rev. bras. cardiol. invasiva ; 23(3): 166-172, jul.-set.2015. tab, ilus, graf
Artigo em Português | LILACS, SES-SP, SESSP-IDPCPROD, SES-SP | ID: lil-794192

RESUMO

Introdução: Estudos recentes têm demonstrado a eficácia do implante transcateter valve-in-valve para otratamento de disfunção de biopróteses em pacientes de alto risco cirúrgico. Apresentamos nossa experiênciainicial com o implante valve-in-valve.Métodos: Caracterizamos o perfil clínico, ecocardiográfico e do procedimento, e reportamos os resultados de médio prazo de pacientes com disfunção de bioprótese submetidos a implante valve-in-valve em posição aórtica. Resultados: Incluímos sete pacientes do sexo masculino, com idade de 72,6 ± 10,0 anos. O escore STS foi 9,6± 10,5%, e o EuroSCORE logístico foi 22,7 ± 14,7%. Três pacientes apresentavam dupla disfunção; dois tinham insuficiência; e dois exibiam estenose isolada. A via transfemoral foi utilizada em seis casos, e a transapical, em um caso. Os dispositivos implantados incluíram as próteses Sapien XT (n = 5) e CoreValve (n = 2). O sucesso do procedimento foi obtido em seis (85,7%) casos. Após o procedimento, o gradiente médio reduziu-se de 38,2 ± 9,6mmHg para 20,9 ± 5,9 mmHg, e a área valvar elevou-se de 1,2 ± 0,4 cm2 para 1,5 ± 0,5 cm2. Ao final de 1 ano, nãoocorreram óbitos e nem outros desfechos adversos significativos; 80% dos pacientes encontravam-se em classefuncional NYHA I/II. Os gradientes transvalvares e a área valvar permaneceram inalterados nesse período. Conclusões: O procedimento valve-in-valve foi eficaz na maioria dos pacientes de alto risco cirúrgico comdisfunção de bioprótese. Quando realizado em pacientes bem selecionados, resulta em desfechos clínicos e hemodinâmicos satisfatórios.


Background: Recent studies have demonstrated the efficacy of the transcatheter valve-in-valveimplantation for the treatment of bioprosthesis dysfunction in high-risk surgical patients. This study presents the initial experience with valve-in-valve implantation. Methods: Clinical, echocardiographic, and procedural profiles were characterized, and the mid-term results of patients with surgical bioprosthesis dysfunction submitted to valve-in-valve implantation in theaortic position were reported.Results: Seven male patients were included, aged 72.6 ± 10.0 years. The STS score was 9,6 ± 10,5%, andthe logistic EuroSCORE was 22.7 ± 14.7%. Three patients had combined aortic bioprosthesis failure; two had isolated regurgitation; and two had isolated stenosis. The transfemoral access was used in six cases, and the transapical access in one case. Implanted devices included Sapien XT (n = 5) and CoreValve (n = 2) prostheses. Procedural success was achieved in six (85.7%) cases. After the procedure, the mean gradient decreased from 38.2 ± 9.6 mmHg to 20.9 ± 5.9 mmHg, and the valve area increased from 1.2 ±0.4 cm2 to 1.5 ± 0.5 cm2. After 1 year, there were no deaths and no other significant adverse outcomes; 80% of patients were in NYHA functional class I/II. The transvalvular gradients and valve area remained unchanged in this period.


Assuntos
Humanos , Masculino , Idoso , Bioprótese , Estenose da Valva Aórtica/diagnóstico , Estenose da Valva Aórtica/terapia , Substituição da Valva Aórtica Transcateter/métodos , Interpretação Estatística de Dados , Ecocardiografia/métodos , Fatores de Risco , Próteses e Implantes/métodos , Medição de Risco/métodos , Tratamento Farmacológico/métodos , Valva Aórtica/cirurgia , Ventrículos do Coração
10.
Rev. bras. cardiol. invasiva ; 23(2): 152-155, abr.-jun. 2015. ilus
Artigo em Português | LILACS | ID: lil-787001

RESUMO

O implante de valva aórtica transcateter (TAVI) é uma alternativa para pacientes com estenose aórtica de alto risco cirúrgico e para muitos daqueles considerados inoperáveis. Apesar de sua característica minimamente invasiva, podem ocorrer complicações relacionadas ao procedimento. Obstrução coronária durante o TAVI é uma complicação rara, com incidência inferior a 1%, mas potencialmente letal. Em nosso país, essa complicação foi encontrada em 0,72% dos procedimentos − 3 de 418 casos do Registro Brasileiro de Implante de Bioprótese Aórtica por Cateter − com mortalidade hospitalar de 100%. Apresentamos, neste relato de caso, medidas de prevenção e tratamento de oclusão coronária após o TAVI.


Transcatheter aortic valve implantation (TAVI) is an alternative for patients with aortic stenosis at high surgical risk and for many of those considered inoperable. Despite its minimally invasive features,complications related to the procedure may occur. Coronary obstruction during TAVI is a rare (incidence rate of less than 1%) but potentially lethal complication. In Brazil, this complication was found in 0.72% of procedures – three of 418 cases from the Brazilian Transcatheter Aortic Valve Implantation Registry – with an in-hospital mortality rate of 100%. This case report presents prevention and treatment measures forcoronary occlusion after TAVI.


Assuntos
Humanos , Feminino , Idoso , Estenose da Valva Aórtica/terapia , Implante de Prótese de Valva Cardíaca/métodos , Oclusão Coronária/complicações , Oclusão Coronária/terapia , Angioplastia/métodos , Artéria Femoral , Catéteres , Ecocardiografia/métodos , Fatores de Risco , Intervenção Coronária Percutânea/métodos , Stents , Valva Aórtica/cirurgia
11.
Rev. bras. cardiol. invasiva ; 23(2): 124-129, abr.-jun. 2015. tab, graf
Artigo em Português | LILACS, SES-SP, SESSP-IDPCPROD, SES-SP | ID: lil-786995

RESUMO

Introdução: A utilização crescente do implante transcateter de prótese valvar aórtica (TAVI) em pacientes de alto risco, em especial naqueles com disfunção ventricular, justifica uma avaliação mais profunda da seleção e dos resultados do procedimento. Utilizamos nosso banco de dados para caracterizar o perfil dos pacientes e avaliar os resultados do TAVI de acordo com o grau de disfunção ventricular.Métodos: Estudo observacional longitudinal no qual foram incluídos todos os pacientes com estenose aórtica (EAo) grave, submetidos ao TAVI entre 2009 e 2014, e comparados àqueles com fração de ejeção do ventrículo esquerdo (FEVE) ≤ 40% vs. > 40%. Foram avaliados os desfechos de segurança e eficácia em 30dias e 1 ano. Resultados: Dentre os 172 pacientes, 20 (11,6%) apresentavam FEVE ≤ 40%. Esses pacientes eram mais jovens, com maior prevalência de tabagismo, infarto agudo do miocárdio prévio, cirurgia de revascularizaçãomiocárdica, marca-passo definitivo e hipertensão arterial pulmonar. Também se observou, nesse grupo, maior frequência de classes funcionais mais elevadas. O grupo com FEVE ≤ 40% apresentou menor gradiente valvar aórtico médio para área valvar equivalente. As taxas de sucesso do procedimento não diferiram entre os grupos. Não foram observadas diferenças na mortalidade, nos eventos coronarianos, cerebrovasculares, sangramentos, complicações vasculares e disfunção renal aguda no acompanhamento de 30 dias e 1 ano. No grupo FEVE ≤ 40%, a média da FEVE elevou-se de 31,5 para 45,1% 1 ano após o procedimento (p = 0,002).Conclusões: O TAVI em pacientes com EAo grave e FEVE ≤ 40% não aumenta o risco de complicações e estáassociado à melhora da FEVE.


Background: The increasing use of transcatheter aortic valve implantation (TAVI) in high-risk patients, especially those with ventricular dysfunction, justifies further evaluation of the selection and the results of the procedure. A database was used to characterize the profile of patients and evaluate TAVI results according to the degree of ventricular dysfunction.Methods: This was a longitudinal observational study that included all patients with severe aortic stenosis(AoS) submitted to TAVI between 2009 and 2014, comparing those with left ventricular ejection fraction (LVEF) ≤ 40% vs. > 40%. The safety and efficacy outcomes were evaluated at 30 days and 1 year. Results: Of the 172 patients, 20 (11.6%) had LVEF ≤ 40%. These patients were younger, with a higherprevalence of smoking, previous acute myocardial infarction, coronary artery bypass graft surgery, permanent pacemaker, and pulmonary artery hypertension. Higher functional classes were also more often observed in this group. The group with LVEF ≤ 40% had lower mean aortic valve gradient for anequivalent valve area. The procedure success did not differ between groups. There were no differences in mortality in coronary and cerebrovascular events, bleeding, vascular complications, and acute renal failure in the 30 day and 1 year follow-up. In the LVEF ≤ 40% group, the mean LVEF increased from 31.5 to 45.1% 1 year after the procedure (p = 0.002). Conclusions: TAVI in patients with severe AoS and LVEF ≤ 40% does not increase the risk of complications and is associated with LVEF improvement.


Assuntos
Humanos , Masculino , Feminino , Idoso , Idoso de 80 Anos ou mais , Disfunção Ventricular Esquerda/fisiopatologia , Estenose da Valva Aórtica/fisiopatologia , Resultado do Tratamento , Substituição da Valva Aórtica Transcateter/métodos , Interpretação Estatística de Dados , Aspirina/administração & dosagem , Ecocardiografia Transesofagiana/métodos , Ecocardiografia/métodos , Estudo Observacional , Próteses e Implantes , Prognóstico , Volume Sistólico
12.
Rev. bras. cir. cardiovasc ; 29(4): 650-653, Oct-Dec/2014. tab, graf
Artigo em Inglês | LILACS | ID: lil-741737

RESUMO

Introdution: The transcatheter aortic valve implantation in the treatment of high-risk symptomatic aortic stenosis has increased the number of implants every year. The learning curve for transcatheter aortic valve implantation has improved since the last 12 years, allowing access alternatives. Objective: The aim of this study is to approach the implantation of transcatheter aortic valve through transaortic via associated with off-pump cardiopulmonary bypass surgery in a 67-year-old man, with chronic obstructive pulmonary disease, arterial hypertension and kidney transplant. Methods: Off-pump coronary artery bypass surgery was performed and the valve in the aortic position was released successfully. Results: There were no complications in the intraoperative and postoperative period. Gradient reduction, effective orifice increasing of the prosthesis and absence of valvular regurgitation after implantation were observed by transesophageal echocardiography. Conclusion: Procedural success demonstrates that implantation of transcatheter aortic valve through the ascending aorta associated with coronary artery bypass surgery without CPB is a new option for these patients. .


Introdução: implante de prótese aórtica transcateter no tratamento da estenose aórtica sintomática de alto risco vem aumentando de número a cada ano no mundo. A curva de aprendizado para implante da prótese aórtica transcateter melhorou os resultados ao longo dos últimos 12 anos, o que permitiu o surgimento de outras vias de acesso como alternativas. Objetivo: Este trabalho refere-se ao implante de prótese aórtica transcateter pela via transaórtica associada à revascularização do miocárdio sem em paciente do sexo masculino de 67 anos com doença pulmonar obstrutiva crônica, hipertensão arterial sistêmica e transplante de rim. Métodos: A revascularização miocárdica e o implante da prótese aórtica transcateter foram realizados com sucesso sem o auxílio da circulação extracorpórea. Resultados: No intra e pós-operatório não houve complicações, a redução do gradiente transvalvar, o aumento do orifício efetivo e ausência de regurgitação paravalvar foram observados pelo ecocardiograma transesofágico. Conclusão: O implante da prótese aórtica transcateter pela aorta ascendente associado com revascularização do miocárdio sem circulação extracorpórea é uma nova alternativa para pacientes de alto rico. .


Assuntos
Idoso , Humanos , Masculino , Aorta , Estenose da Valva Aórtica/cirurgia , Ponte de Artéria Coronária/métodos , Substituição da Valva Aórtica Transcateter/métodos , Aorta , Estenose da Valva Aórtica , Ecocardiografia Transesofagiana , Reprodutibilidade dos Testes , Resultado do Tratamento
13.
Arq. bras. cardiol ; 102(4): 336-344, abr. 2014. tab, graf
Artigo em Português | LILACS, SES-SP, SESSP-IDPCPROD, SES-SP | ID: lil-709323

RESUMO

Fundamento: O implante de prótese aórtica transcateter é uma alternativa efetiva para o tratamento cirúrgico para a correção de estenose aórtica grave em pacientes inoperáveis ou de alto risco cirúrgico. Objetivos: Apresentar os resultados clínicos e ecocardiográficos imediatos e no médio prazo da experiência inicial do implante de prótese aórtica transcateter. Métodos: Entre junho de 2009 e fevereiro de 2013, 112 pacientes foram submetidos a implante de prótese aórtica transcateter. Resultados: A idade média foi 82,5 ± 6,5 anos e o Euro SCORE logístico foi 23,6 ± 13,5. O sucesso do procedimento foi de 84%. Após o implante, houve queda do gradiente sistólico médio (pré = 54,7 ± 15,3 mmHg vs. pós = 11,7 ± 4,0 mmHg; p < 0,01). Acidente vascular cerebral ocorreu em 3,6% dos pacientes, complicações vasculares em 19%, e foi necessário o implante de marca-passo definitivo em 13% dos pacientes nos primeiros 30 dias pós-implante. A mortalidade aos 30 dias e no seguimento médio de 16 ± 11 meses foi, respectivamente, de 14 e de 8,9%. A presença de doença pulmonar obstrutiva crônica foi o único preditor de mortalidade em 30 dias e no seguimento. A área valvar aórtica e o gradiente sistólico médio não apresentaram variações significativas durante o seguimento. Conclusões: O implante de prótese aórtica transcateter é um procedimento eficaz e seguro para o tratamento da estenose aórtica em pacientes de alto risco cirúrgico ou inoperáveis. A presença de doença pulmonar obstrutiva crônica foi o único preditor independente de mortalidade identificado, tanto no primeiro mês pós-intervenção quanto no seguimento mais tardio. .


Background: Transcatheter aortic valve implantation is an effective alternative to surgical treatment of severe aortic stenosis in patients who are inoperable or at high surgical risk. Objectives: To report the immediate and follow-up clinical and echocardiographic results of the initial experience of transcatheter aortic valve implantation. Methods: From 2009 June to 2013 February, 112 patients underwent transcatheter aortic valve implantation. Results: Mean age was 82.5 ± 6.5 years, and the logistic EuroSCORE was 23.6 ± 13.5. Procedural success was 84%. After the intervention, a reduction in the mean systolic gradient was observed (pre: 54.7 ± 15.3 vs. post: 11.7 ± 4.0 mmHg; p < 0.01). Cerebrovascular accidents occurred in 3.6%, vascular complications in 19% and permanent pacemaker was required by 13% of the patients. Thirty-day mortality and at follow-up of 16 ± 11 months was 14% and 8.9% respectively. The presence of chronic obstructive pulmonary disease was the only predictor of mortality at 30 days and at follow-up. During follow up, aortic valve area and mean systolic gradient did not change significantly. Conclusions: Transcatheter aortic valve implantation is an effective and safe procedure for the treatment of aortic stenosis in high-surgical risk or inoperable patients. The presence of chronic obstructive pulmonary disease was the only independent predictor of mortality identified both in the first month post-intervention and at follow-up. .


Assuntos
Humanos , Masculino , Feminino , Idoso , Idoso de 80 Anos ou mais , Estenose da Valva Aórtica/cirurgia , Cateterismo Cardíaco/métodos , Próteses Valvulares Cardíacas , Implante de Prótese de Valva Cardíaca/métodos , Estenose da Valva Aórtica/mortalidade , Estenose da Valva Aórtica , Cateterismo Cardíaco/efeitos adversos , Cateterismo Cardíaco/mortalidade , Ecocardiografia Doppler , Seguimentos , Implante de Prótese de Valva Cardíaca/efeitos adversos , Implante de Prótese de Valva Cardíaca/mortalidade , Hemodinâmica , Estimativa de Kaplan-Meier , Complicações Pós-Operatórias , Medição de Risco , Fatores de Risco , Estatísticas não Paramétricas , Acidente Vascular Cerebral/etiologia , Fatores de Tempo , Resultado do Tratamento
14.
Rev. bras. cir. cardiovasc ; 29(1): 45-50, Jan-Mar/2014. tab, graf
Artigo em Português | LILACS | ID: lil-710083

RESUMO

Objetivo: Descrever, em idosos, a correlação entre faixa etária e ocorrência de fibrilação atrial após cirurgia por estenose aórtica, além de avaliar a influência da ocorrência de fibrilação atrial na incidência de acidente vascular cerebral, tempo de internação e mortalidade hospitalar. Métodos: Estudo transversal retrospectivo incluindo pacientes com idade > 70 anos submetidos à cirurgia de troca valvar aórtica isolada. Resultados: Foram estudados 348 pacientes com idade média de 76,8±4,6 anos. A incidência de fibrilação atrial no pós-operatório foi 32,8% (n=114), sendo superior nos pacientes > 80 anos (42,9 vs. 28,8% 70-79 anos, P=0,017) e havendo significância estatística limítrofe (P=0,055) para tendência linear na correlação idade e incidência de fibrilação atrial. Verificou-se significativo maior tempo de internação na Unidade de Terapia Intensiva e hospitalar total, porém, não se observou maior taxa de acidente vascular cerebral ou de mortalidade hospitalar decorrente da fibrilação atrial. Conclusão: A incidência de fibrilação atrial no pós-operatório de cirurgia para estenose valvar aórtica em pacientes idosos com > 70 anos foi elevada e linearmente correlacionada ao avanço da idade, especialmente após 80 anos, causando aumento dos tempos de internação total e em Unidade de Terapia Intensiva, sem aumento significativo da morbimortalidade. O conhecimento desses dados é importante para evidenciar a necessidade de medidas profiláticas e de tratamento precoce dessa arritmia nesse subgrupo. .


Objective: This study aims to describe the correlation between age and occurrence of atrial fibrillation after aortic stenosis surgery in the elderly as well as evaluate the influence of atrial fibrillation on the incidence of strokes, hospital length of stay, and hospital mortality. Methods: Cross-sectional retrospective study of > 70 year-old patients who underwent isolated aortic valve replacement. Results: 348 patients were included in the study (mean age 76.8±4.6 years). Overall, post-operative atrial fibrillation was 32.8% (n=114), but it was higher in patients aged 80 years and older (42.9% versus 28.8% in patients aged 70-79 years, P=0.017). There was borderline significance for linear correlation between age and atrial fibrillation (P=0.055). Intensive Care Unit and hospital lengths of stay were significantly increased in atrial fibrillation (P<0.001), but there was no increase in mortality or stroke associated with atrial fibrillation. Conclusion: Post-operative atrial fibrillation incidence in aortic valve replacement is high and correlates with age in patients aged 70 years and older and significantly more pronounced in patients aged 80 years. There was increased length of stay at Intensive Care Unit and hospital, but there was no increase in mortality or stroke. These data are important for planning prophylaxis and early treatment for this subgroup. .


Assuntos
Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Estenose da Valva Aórtica/cirurgia , Fibrilação Atrial/etiologia , Implante de Prótese de Valva Cardíaca/efeitos adversos , Complicações Pós-Operatórias/etiologia , Doença Aguda , Distribuição por Idade , Fatores Etários , Estenose da Valva Aórtica/mortalidade , Fibrilação Atrial/mortalidade , Estudos Transversais , Mortalidade Hospitalar , Implante de Prótese de Valva Cardíaca/mortalidade , Unidades de Terapia Intensiva , Tempo de Internação , Complicações Pós-Operatórias/mortalidade , Estudos Retrospectivos , Fatores de Risco , Acidente Vascular Cerebral/etiologia , Acidente Vascular Cerebral/mortalidade , Fatores de Tempo
15.
Rev. bras. cardiol. invasiva ; 21(3): 221-226, 2013. graf, tab
Artigo em Português | LILACS | ID: lil-690652

RESUMO

INTRODUÇÃO: A valvuloplastia aórtica por cateter balão (VAB) é utilizada como estratégia paliativa em pacientes inelegíveis tanto para troca valvar cirúrgica quanto para implante valvar aórtico transcateter, ou como ponte para essas modalidades de tratamento. Não se sabe o impacto terapêutico da VAB quando realizada como medida de salvamento para pacientes em condições clínicas extremas (in extremis). MÉTODOS: Foram analisados pacientes com estenose aórtica grave de etiologia degenerativa submetidos à VAB entre julho de 2008 e janeiro de 2013. Os pacientes foram divididos entre o grupo in extremis (definido pela presença de duas ou mais das seguintes disfunções orgânicas: ventilação mecânica, instabilidade hemodinâmica, terapia renal dialítica, coagulopatia ou disfunção hepática graves) e o grupo controle, que incluiu os demais pacientes. RESULTADOS: Um total de 19 pacientes realizaram VAB no período. A condição clínica in extremis esteve presente em 42,1%. Os pacientes do grupo in extremis tiveram EUROSCORE II mais elevado (41,1 ± 24,7 vs. 15,9 ± 14,0; P = 0,01) e fração de ejeção do VE mais baixa que o grupo controle (33,9 ± 17,3% vs. 49,0 ± 12,5%; P = 0,04). Nenhum paciente do grupo in extremis sobreviveu ao período intra-hospitalar, enquanto que, no grupo controle, a mortalidade foi de 27,3% (P < 0,01). CONCLUSÕES: Para o tratamento de pacientes com estenose aórtica grave de etiologia degenerativa, a VAB tem resultado desfavorável quando indicada para pacientes com duas ou mais disfunções orgânicas, ou seja, em condição clínica in extremis.


BACKGROUND: Balloon aortic valvuloplasty (BAV) is used as a palliative strategy in patients who are not eligible for valve replacement surgery, transcatheter aortic valve implantation, or as a bridge to these treatment modalities. The impact of BAV as a salvage procedure for patients in extreme clinical conditions (in extremis) is unknown. METHODS: Patients with severe degenerative aortic stenosis undergoing BAV between July 2008 and January 2013 were evaluated. Patients were divided into the in-extremis group (defined by the presence of two or more of the following organ dysfunctions: mechanical ventilation, hemodynamic instability, dialysis, coagulopathy or severe hepatic dysfunction) and the control group, which included the remaining patients. RESULTS: A total of 19 patients underwent BAV. The clinical condition in-extremis was present in 42.1% of them. Patients from the in-extremis group had a higher EUROSCORE II (41.1 ± 24.7 vs. 15.9 ± 14.0; P = 0.001) and LV ejection fraction lower than the control group (33.9 ± 17.3% vs. 49.0 ± 12.5; P = 0.04). None of the patients in the in-extremis group survived past the hospitalization period, whereas the control group mortality was 27.3% (P < 0.01). CONCLUSIONS: BAV has an unfavorable result in patients with severe degenerative aortic stenosis with two or more organ dysfunctions, that is, patients in extremis.


Assuntos
Humanos , Masculino , Feminino , Idoso , Estenose da Valva Aórtica/complicações , Estenose da Valva Aórtica/mortalidade , Implante de Prótese de Valva Cardíaca , Valvuloplastia com Balão/instrumentação , Análise de Dados/análise , Ecocardiografia/métodos , Fatores de Risco
16.
Rev. bras. cir. cardiovasc ; 27(3): 355-361, jul.-set. 2012. ilus, tab
Artigo em Português | LILACS | ID: lil-660805

RESUMO

INTRODUÇÃO: A reoperação para substituição de biopróteses aórticas com disfunção é procedimento que envolve considerável risco. Em alguns casos, a mortalidade é elevada e pode contraindicar o procedimento. O implante minimamente invasivo "valve-in-valve" transcateter de valva aórtica parece ser uma alternativa, reduzindo morbimortalidade. O objetivo deste estudo foi avaliar esses implantes utilizando a prótese Braile Inovare. MÉTODOS: A prótese Braile Inovare, transcateter, balão expansível foi utilizada em 14 casos. Euroscore médio foi de 42,9%. Todos os pacientes eram portadores de dupla disfunção de bioprótese aórtica. Os procedimentos foram realizados em ambiente cirúrgico híbrido, sob controle ecocardiográfico e fluoroscópico. Por meio de minitoracotomia esquerda, as próteses foram implantadas através do ápice ventricular, sob estimulação ventricular de alta frequência. Foram realizados controles clínicos e ecocardiográficos seriados. O seguimento variou de 1 a 30 meses. RESULTADOS: A correta liberação protética foi possível em todos os casos. Não ocorreu conversão. Não houve mortalidade operatória. A mortalidade em 30 dias foi de 14,3% (dois casos). A fração de ejeção apresentou aumento significativo após o 7º pós-operatório e o gradiente aórtico apresentou redução significativa. A insuficiência aórtica residual não esteve presente. Não ocorreu complicação vascular periférica ou bloqueio atrioventricular total. CONCLUSÕES: O implante "valve-in-valve" de valva aórtica transcateter em biopróteses com disfunção é um procedimento seguro e com morbimortalidade baixa. Essa possibilidade poderá alterar a indicação de seleção de prótese no procedimento inicial, favorecendo próteses biológicas.


OBJECTIVE: Aortic valve replacement for bioprosthesis dysfunction is a procedure involving considerable risk. In some cases, mortality is high and may contraindicate the procedure. Minimally invasive transcatheter aortic "valve-in-valve" implant appears to be an alternative, reducing morbidity and mortality. The objective is to evaluate aortic valve-in-valve procedure using Braile Inovare prosthesis. METHODS: The Braile Inovare prosthesis, transcatheter, expandable balloon, was used in 14 cases. Average EuroSCORE was 42.9%. All patients had double aortic bioprosthesis dysfunction. Procedures were performed in a surgical hybrid environment under echocardiographic and fluoroscopic guidance. Using left minithoracotomy prostheses were implanted through the ventricular apex under high-frequency ventricular pacing. Serial clinical and echocardiographic controls were performed. Follow-up ranged 1-30 months. RESULTS: Correct prosthetic deployment was obtained in all cases. There was no conversion. There was no operative mortality. The 30-day mortality was 14.3% (two cases). Ejection fraction increased significantly after the 7th postoperative day. Aortic gradient significantly reduced. The residual aortic regurgitation was not present. There were no vascular complications or complete atrioventricular block. CONCLUSION: The transcatheter "valve-in-valve" procedure for bioprosthesis dysfunction is safe with low morbidity. This possibility may change prosthesis choice during the first aortic valve replacement, favoring bioprostheses.


Assuntos
Idoso , Feminino , Humanos , Masculino , Estenose da Valva Aórtica/cirurgia , Bioprótese , Cateterismo Cardíaco/métodos , Próteses Valvulares Cardíacas , Implante de Prótese de Valva Cardíaca/métodos , Estenose da Valva Aórtica/mortalidade , Cateterismo Cardíaco/mortalidade , Implante de Prótese de Valva Cardíaca/mortalidade , Estimativa de Kaplan-Meier , Reprodutibilidade dos Testes , Medição de Risco , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento
17.
Arq. bras. cardiol ; 99(2): 697-705, ago. 2012. graf, tab
Artigo em Português | LILACS | ID: lil-647716

RESUMO

FUNDAMENTO: O implante por cateter de bioprótese valvar aórtica é uma nova modalidade de tratamento para portadores de estenose aórtica inoperáveis ou de alto risco cirúrgico. Objetivo: Relatar a experiência de três anos do implante por cateter da bioprótese CoreValve. MÉTODOS: Entre janeiro de 2008 e janeiro de 2011, 35 pacientes com estenose aórtica (33 casos) ou disfunção de bioprótese valvar aórtica (dois casos) de alto risco cirúrgico foram submetidos ao implante da bioprótese CoreValve. RESULTADOS: A média de idade dos pacientes foi 81,5 ± 9 anos, e 80% apresentavam-se em classe funcional III ou IV de insuficiência cardíaca. O EuroScore foi 18,4 ± 14,3% e o STS 14,5 ± 11,6%. Obteve-se sucesso do implante em 34 (97,1%) pacientes. Após a intervenção houve redução do gradiente transvalvar de 84,9 ± 22 para 22,5 ± 9,5 mmHg e 87,1% dos pacientes evoluíram em classe funcional I ou II. A mortalidade aos 30 dias e no seguimento médio de 400 ± 298 dias foi, respectivamente, de 11,4% e 31,4%. A ocorrência de complicações hemorrágicas com risco de morte foi o único preditor independente de mortalidade cardiovascular. Acidente vascular cerebral ocorreu em 5,7% dos pacientes. Marca-passo permanente foi necessário em 32,1% dos casos no primeiro mês após o procedimento. CONCLUSÃO: O implante por cateter de bioprótese valvar aórtica é um procedimento seguro e eficaz para ser empregado em portadores de estenose aórtica de alto risco cirúrgico. O dispositivo CoreValve é eficaz no médio-prazo, em seguimento de até três anos.


BACKGROUND: Transcatheter aortic bioprosthesis implantation is a new treatment modality for patients with aortic stenosis who are inoperable or at high surgical risk. OBJECTIVE: To report the three-year experience with transcatheter CoreValve® bioprosthesis implantation. METHODS: From January 2008 to January 2011, 35 patients with aortic stenosis (33) or aortic valve bioprosthesis dysfunction (two) at high surgical risk underwent transcatheter CoreValve® bioprosthesis implantation. RESULTS: The patients' mean age was 81.5 ± 9 years, and 80% had heart failure functional class III or IV. The EuroScore was 18.4 ± 14.3% and the STS risk score was 14.5 ± 11.6%. Successful device implantation was achieved in 34 (97.1%) patients. After the intervention, a reduction in the transvalvular pressure gradient from 84.9 ± 22 to 22.5 ± 9.5 mm Hg was observed, and 87.1% of the patients progressed to functional class I or II. Thirty-day mortality and mortality in the follow-up of 400 ± 298 days were 11.4% and 31.4%, respectively. The occurrence of life-threatening hemorrhagic complications was the only independent predictor of cardiovascular mortality. Stroke occurred in 5.7% of the patients. Permanent pacemaker was required in 32.1% of the patients within the first month after the procedure. CONCLUSION: Transcatheter aortic bioprosthesis implantation is a safe and effective procedure to be used in patients with aortic stenosis at high surgical risk. The CoreValve® prosthesis proved to have mid-term efficacy in a three-year follow-up.


Assuntos
Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estenose da Valva Aórtica/terapia , Bioprótese , Cateterismo Cardíaco/métodos , Próteses Valvulares Cardíacas , Implante de Prótese de Valva Cardíaca/métodos , Cateterismo Cardíaco/efeitos adversos , Determinação de Ponto Final , Métodos Epidemiológicos , Implante de Prótese de Valva Cardíaca/efeitos adversos , Complicações Pós-Operatórias , Resultado do Tratamento
18.
Rev. bras. cir. cardiovasc ; 27(2): 267-274, abr.-jun. 2012. ilus, tab
Artigo em Português | LILACS | ID: lil-649603

RESUMO

INTRODUÇÃO: O aumento da expectativa de vida da população tem levado à maior necessidade de intervenções cirúrgicas sobre a valva aórtica. OBJETIVOS: Avaliar a mortalidade precoce e a médio prazo, a necessidade de reoperação para troca valvar e complicações valvares [tromboembolismo sistêmico (TES) e endocardite infecciosa em prótese (EI)] em pacientes acima de 75 anos submetidos a cirurgia de estenose aórtica. MÉTODOS: Estudo retrospectivo de 230 casos, operados no período de 2002 a 2007. A idade média foi de 83,4 anos, sendo 53% do sexo masculino, 73,2% hipertensos, 17,9% portadores de fibrilação atrial e 14,4% com cirurgia cardíaca prévia. Outro procedimento cardíaco esteve associado em 39,1% dos casos. RESULTADOS: Em 4,51 anos de seguimento médio, a sobrevida geral foi de 57,4%. Ocorreram 13,9% óbitos intra-hospitalares (9,4% no grupo cirurgia de estenose aórtica isolada vs. 20,9% quando outro procedimento cirúrgico foi associado) e 28,7% óbitos após a alta hospitalar (25,0% vs. 34,4%), com 34 destes por causas cardiovasculares. Ocorreram seis casos de EI, oito casos de TES e seis reoperações para troca valvar. Os preditores de mortalidade geral foram: tempo de isquemia >90 min (RC 1,99 IC 95% 1,06-3,74), fração de ejeção <60% (RC 1,76 IC 95% 1,10-2,81) e acidente vascular encefálico prévio (RC 2,43 IC 95% 1,18-5,30). CONCLUSÃO: Ainda que o risco cirúrgico imediato de idosos seja elevado, as taxas de sobrevida referentes ao tratamento cirúrgico em pacientes acima de 75 anos são aceitáveis e permitem essa intervenção. O prognóstico é agravado, sobretudo, pela associação com doença arterial coronariana.


BACKGROUND: The increased longevity elevated the frequency of elderly requiring surgery, among them the correction of aortic stenosis. OBJECTIVES: To evaluate medium-term mortality, need for reoperation for valve replacement and valve complications [systemic thromboembolism (STE) and prosthetic endocarditis (PE)] in patients over 75 years old who had undergone surgery for aortic stenosis. METHODS: Retrospective study of 230 patients from 2002 to 2007. Mean age was 83.4 years and 53% were male. The prevalence of hypertension was 73.2%, atrial fibrillation 17.9% and previous cardiac surgery 14.4%. Another cardiac procedure was associated in 39.1%. RESULTS: In a mean follow-up of 4.51 years the overall survival of the population studied was 57.4%. Death in the immediate postoperative period occurred in 13.9% (9.4% in the isolated aortic stenosis surgery group vs. 20.9% when another procedure was associated). Deaths in the medium term occurred in 28.7% of the patients (25.0% vs. 34.4%), with 34 of these because of cardiovascular causes. There were 6 cases of PE, 8 cases of STE and 6 reoperations. The predictors of mortality were ischemia time >90 min (OR 1.99 95% CI 1.06-3.74), ejection fraction <60% (OR 1.76 95% CI 1.10-2.81) and prior stroke (OR 2.43 95% CI 1.18-5.30). CONCLUSION: Although the immediate surgical risk of the elderly is high, survival rates for surgical treatment of patients over 75 years old are acceptable and allow this intervention. The prognosis is worse especially because of the association with coronary artery disease.


Assuntos
Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Estenose da Valva Aórtica/mortalidade , Estenose da Valva Aórtica/cirurgia , Procedimentos Cirúrgicos Cardíacos/efeitos adversos , Complicações Intraoperatórias/mortalidade , Fatores Etários , Brasil , Métodos Epidemiológicos , Reoperação , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento
19.
Arq. bras. cardiol ; 95(4): 541-546, out. 2010.
Artigo em Português | LILACS | ID: lil-568953

RESUMO

A estenose valvar aórtica é cada vez mais prevalente concordante com o envelhecimento populacional. Por conseguinte, torna-se mais comum o atendimento de pacientes assintomáticos com estenose aórtica grave. Embora os pacientes com estenose aórtica grave sem sintomas façam parte de um mesmo grupo, são heterogêneos sob o ponto de vista clínico, laboratorial e ecocardiográfico. A abordagem desses pacientes traz à tona o dilema do tratamento clínico versus cirúrgico: submeter o paciente aos riscos da cirurgia ou mantê-lo em observação clínica sob o perigo do dano miocárdio irreversível ou mesmo da morte súbita? Sob esta perspectiva, baseando-se na literatura atual, este artigo fornece ferramentas que auxiliam na estratificação dos pacientes. A área valvar, grau de calcificação, velocidade de fluxo transvalvar aórtico, hipertrofia ventricular esquerda e teste de esforço alterado são os fatores que colocam os portadores de estenose aórtica grave assintomáticos em um grupo denominado de muito alto risco, em que a estratégia cirúrgica passa a ser considerada.


Aortic valve stenosis has become increasingly prevalent, in agreement with the aging of the population. Thus, it has become increasingly common to treat asymptomatic patients with severe aortic stenosis. Although the patients with asymptomatic aortic stenosis belong to the same group, they are heterogeneous from a clinical, laboratory and echocardiographic point of view. The treatment of these patients raises the dilemma of the clinical versus the surgical treatment: should we submit the patient to the risks of surgery or keep the patient under clinical observation, running the risk of irreversible myocardial damage or even sudden death? Under this perspective and based on the current literature, this study supplies tools that help to stratify the patients. The valvular area, degree of calcification, transvalvular aortic flow velocity, left ventricular hypertrophy and stress test alterations are the factors that place asymptomatic individuals with severe aortic stenosis in a group called very-high risk, in which the surgical approach starts to be considered.


La estenosis valvular aórtica es cada vez más prevalente concordante con el envejecimiento poblacional. Por consiguiente, se vuelve más común la atención de pacientes asintomáticos con estenosis aórtica grave. Aunque los pacientes con estenosis aórtica grave sin síntomas hagan parte de un mismo grupo, son heterogéneos bajo el punto de vista clínico, de laboratorio y ecocardiográfico. El abordaje de esos pacientes trae a cuento el dilema del tratamiento clínico versus quirúrgico: someter el paciente a los riesgos de la cirugía o mantenerlo en observación clínica bajo el peligro de daño miocárdico irreversible o aun de muerte súbita? Bajo esta perspectiva, basándose en la literatura actual, este artículo provee herramientas que auxilian en la estratificación de los pacientes. El área valvar, grado de calcificación, velocidad de flujo transvalvar aórtico, hipertrofia ventricular izquierda y test de esfuerzo alterado son los factores que colocan a los portadores de estenosis aórtica grave asintomáticos en un grupo denominado de muy alto riesgo, en que la estrategia quirúrgica pasa a ser considerada.


Assuntos
Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estenose da Valva Aórtica/terapia , Doenças Assintomáticas/terapia , Tomada de Decisões/fisiologia , Padrões de Prática Médica , Fatores de Risco
20.
Rev. bras. cir. cardiovasc ; 25(3): 293-302, jul.-set. 2010. ilus, tab
Artigo em Português | LILACS | ID: lil-564994

RESUMO

OBJETIVO: A troca valvar aórtica é procedimento rotineiro com risco aceitável. Em alguns casos, a mortalidade é elevada, levando à contraindicação do procedimento, apesar dos sintomas. O implante minimamente invasivo transcateter de valva aórtica parece ser uma alternativa, reduzindo a morbi-mortalidade. O objetivo deste estudo foi o desenvolvimento e implante de nova prótese para implante transcateter. MÉTODOS: Após desenvolvimento em animais, uma prótese transcateter, balão-expansível foi utilizada em 14 casos de alto risco. O EuroSCORE médio foi de 43,7 por cento. Quatro pacientes apresentavam disfunção de biopróteses e o restante, estenose aórtica calcificada. Todos os pacientes eram sintomáticos. Os procedimentos foram realizados em ambiente cirúrgico híbrido, sob controle ecocardiográfico e fluoroscópico. Com o uso de minitoracotomia esquerda, as próteses foram implantadas através do ápice ventricular, sob estimulação ventricular de alta frequência ou choque hemorrágico controlado, após valvoplastia aórtica. Foram realizados controles clínicos e ecocardiográficos seriados. RESULTADOS: A correta liberação da prótese foi possível em 13 casos. Uma conversão ocorreu. Não houve mortalidade operatória. O gradiente de pico médio pós-implante foi de 25 mmHg. A fração de ejeção apresentou aumento significativo após o 7º pós-operatório. Insuficiência aórtica residual não significativa esteve presente em 71 por cento dos casos, nenhuma significativa. Não ocorreu complicação vascular periférica. Não houve necessidade de marcapasso definitivo. Um caso de acidente vascular cerebral ocorreu. A mortalidade geral foi de 42 por cento. CONCLUSÃO: O implante transapical de valva aórtica transcateter é um procedimento possível com esta nova prótese. O comportamento hemodinâmico foi satisfatório. São necessários estudos de longo prazo e com maior poder amostral, no intuito de determinar a real eficácia e indicação do procedimento alternativo.


OBJECTIVE: The aortic valve replacement is a routine procedure with acceptable risk, but in some cases, such a risk can justify contraindication. The minimally invasive transcatheter aortic valve implantation has been viable, with lower morbidity and mortality. The aim of this study was to develop a national catheter-mounted aortic bioprosthesis for the aortic position implant. METHODS: After animal studies, 14 patients with high EuroSCORE underwent transcatheter aortic valve implantation. Median Logistic EuroSCORE was 43.7 percent. Four patients presented with dysfunctional bioprosthesis, remaining ones presented calcified aortic stenosis. All patients presented symptoms. Procedures were performed in a hybrid OR under fluoroscopic and echocardiography guidance. Using a left minithoracotomy the prosthesis was implanted through the ventricular apex under ventricular pacing or hemorrhagic shock, after aortic valvoplasty. Echocardiograph and angiograph controls were performed, and the patients were referred to ICU. RESULTS: Implant was feasible in 13 cases. There were no intra-operative deaths. Median peak transvalvular aortic gradient reduced to 25.0 mmHg, and left ventricular function improved in the first seven post-operative days. Paravalvular aortic regurgitation was mild and present in 71 percent. No definitive pacemaker was needed. There was no peripheral vascular complication. Overall mortality was 42 percent. CONCLUSION: The transapical implantation of cathetermounted bioprosthesis was a feasible procedure. Long term follow-up is mandatory in order to access efficacy and indications.


Assuntos
Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estenose da Valva Aórtica/cirurgia , Implante de Prótese de Valva Cardíaca/métodos , Toracotomia/métodos , Aortografia , Cateterismo Cardíaco/métodos , Implante de Prótese de Valva Cardíaca/mortalidade , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA