Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 46
Filtrar
Mais filtros







Base de dados
Indicadores
Intervalo de ano de publicação
1.
Arq. bras. oftalmol ; 83(2): 141-145, Mar.-Apr. 2020. tab, graf
Artigo em Inglês | LILACS | ID: biblio-1088976

RESUMO

ABSTRACT Purpose: To compare the postoperative refractive predictability of IOLMaster 500 and Pentacam HR on the basis of keratometry and anterior chamber depth values in eyes with an indication for multifocal intraocular lens (IOL) implantation. Methods: This was a retrospective study conducted on 118 eyes treated with phacoemulsification and multifocal intraocular lens implantation. Only the eyes that achieved emmetropia in the dynamic refraction performed on postoperative day 30 were included. Haigis' formula was used in each case to calculate the intraocular lens power, and the intraocular lens with the target refraction closest to emmetropia was implanted. Four lens calculation scenarios were tested by combining keratometry and anterior chamber depth measurements obtained using the two devices. Results: IOLMaster 500 and Pentacam HR differed with regard to mean keratometry (D 0.07 ± 0.03 D; p=0.0065) and anterior chamber depth (D 0.08 ± 0.01 mm; p<0.001). In the analysis of covariance, the following differences were obtained using the Haigis' formula when confronted with the biometric values obtained by inserting keratometry and anterior chamber depth values, respectively: Penta/IOL x IOL/Penta (0.13 ± 0.03; p<0.0001); Penta/Penta × IOL/Penta (0.13 ± 0.03; p<0.0001); Penta/IOL × IOL/IOL (0.11 ± 0.03; p=0.001); Penta/Penta × IOL/IOL (0.11 ± 0.03; p=0.002); IOL/IOL × IOL/Penta (0.02 ± 0.03; p=0.865); and Penta/IOL × Penta/Penta (0.002 ± 0.03; p=0.99). The difference was smaller when measuring the anterior chamber depth using the IOLMaster 500, regardless of which device was used to measure keratometry. Conclusions: Pentacam HR significantly differed from IOLMaster 500 when calculating keratometry. As regards the anterior chamber depth, the two devices were equally accurate.


RESUMO Objetivo: Comparar a previsibilidade refrativa pós-operatória do IOLMaster 500 e Pentacam HR com base nos valores de ceratometria e profundidade de câmara anterior nos olhos com indicação de implante de lentes intraoculares multifocais. Métodos: Estudo retrospectivo realizado em 118 olhos tratados com facoemulsificação e implante de lentes intraoculares multifocal. Apenas os olhos que atingiram a emetropia na refração dinâmica no 30º dia pós-operatório foram incluídos. A fórmula de Haigis foi usada em cada caso para calcular o poder das lentes intraoculares, e a lente intraocular com a refração alvo mais próxima da emetropia foi implantada. Cenários de cálculo de quatro lentes foram testados pela combinação de medidas de ceratometria e profundidade de câmara anterior obtidas usando os dois dispositivos. Resultados: IOLMaster 500 e Pentacam HR diferiram quanto à média de ceratometria (D 0,07 ± 0,03 D; p=0,0065) e profundidade de câmara anterior (D 0,08 ± 0,01 mm; p<0,001). Na análise da covariância, as seguintes diferenças foram obtidas usando a fórmula de Haigis quando confrontadas com os valores biométricos obtidos pela inserção dos valores de ceratometria e profundidade de câmara anterior, respectivamente: Penta/IOL x IOL/Penta (0,13 ± 0,03; p<0,0001); Penta/Penta x IOL/Penta (0,13 ± 0,03; p<0,0001); Penta/IOL x IOL/IOL (0,11 ± 0,03; p=0,001); Penta/Penta x IOL/IOL (0,11 ± 0,03; p=0,002); IOL/IOL x IOL/Penta (0,02 ± 0,03; p=0,865); Penta/IOL x Penta/Penta (0,002 ± 0,03; p=0,99). A diferença foi menor ao medir a profundidade da câmara anterior usando o IOLMaster 500, independentemente de qual dispositivo foi usado para medir a ceratometria. Conclusões: O Pentacam HR diferiu significativamente do IOLMaster 500 no cálculo de ceratometria. Quanto à profundidade da câmara anterior, os dois dispositivos foram igualmente precisos.


Assuntos
Humanos , Masculino , Feminino , Pessoa de Meia-Idade , Idoso , Facoemulsificação/métodos , Córnea/patologia , Topografia da Córnea/instrumentação , Implante de Lente Intraocular/métodos , Lentes Intraoculares Multifocais , Câmara Anterior/patologia , Período Pós-Operatório , Valores de Referência , Refração Ocular/fisiologia , Fatores de Tempo , Acuidade Visual/fisiologia , Valor Preditivo dos Testes , Estudos Retrospectivos , Biometria , Resultado do Tratamento , Córnea/diagnóstico por imagem , Interferometria/instrumentação , Interferometria/métodos , Câmara Anterior/diagnóstico por imagem
2.
J. health med. sci. (Print) ; 6(1): 57-63, ene.-mar. 2020. tab, ilus
Artigo em Espanhol | LILACS | ID: biblio-1096722

RESUMO

El objetivo de este trabajo fue determinar la relación entre el pronóstico visual según el Ocular Trauma Score (OTS) y la agudeza visual (AV) a los 6 meses de ocurrido el trauma ocular, en pacientes atendidos en la Unidad de Trauma Ocular del Hospital del Salvador, Santiago de Chile. Se hizo uso de un estudio descriptivo, longitudinal, retrospectivo. Se accedió a los registros clínicos de pacientes atendidos por trauma ocular grave entre el 1 de enero de 2014 al 15 de marzo 2015. 145 pacientes conformaron una muestra de 153 ojos. Se estableció la relación entre OTS obtenido y la AV a 6 meses del trauma mediante el coeficiente de correlación de Spearman. De los ojos estudiados, el grupo mayor N=68 (44,4%) calificó para OTS 3 y el menor N=16 (10,5%) para OTS 1. Se presentaron cinco categorías de visión, en un tiempo inicial la mayoría de los casos presentaron AV de luz, mala proyección-cuenta dedos (n=89). Tras seis meses dicha distribución se desplazó hacia la categoría 20/40 - 20/20 (n=68). Se encontró una fuerte asociación (r=0,711 p=0,000) entre el OTS calculado y la AV luego de seis meses de seguimiento. El OTS demostró poseer un gran valor predictivo y es una herramienta aplicable en nuestro medio, los datos obtenidos indican que existe un mejor pronóstico visual que los obtenidos en otro estudio. Cabe destacar que es la primera instancia en que se evalúa la aplicación del OTS en Chile.


This work aimed to determine the relationship between the visual prognosis according to the Ocular Trauma Score (OTS) and visual acuity (AV) 6 months after the ocular trauma in patients treated at the Eye Trauma Unit from the Hospital del Salvador, in Santiago, Chile. A descriptive, longitudinal and retrospective study was performed. We accessed registers of clinical patients attended for severe eye trauma from 1 January 2014 to 15 March 2015. 145 patients constitute a sample of 153 eyes. A connection was established between the OTS obtained and the AV 6 months after the trauma via the Spearman correlation coefficient. From the eyes studied, the greatest group N=68 (44.4%) qualified for OTS 3 and the smallest N=16 (10.5%) for OTS 1. Five eye categories were presented, in the beginning, most of the cases presented visual acuity with bad projection ­ hand motion (n=89). After six months of distribution, it moved to the category 20/40 ­ 20/20 (n=68). A strong relation (r=0,711 p=0,000) was found between the estimated OTS and the AV after six months of tracking. The OTS proved to have great predictive valor and is an applicable tool in our area, the data obtained showed that there is a better visual prognosis than the obtained in other studies. It is worth noting that this is the first stage where the application of OTS is assessed in Chile.


Assuntos
Humanos , Masculino , Feminino , Pré-Escolar , Criança , Adolescente , Adulto , Pessoa de Meia-Idade , Idoso , Idoso de 80 Anos ou mais , Adulto Jovem , Acuidade Visual/fisiologia , Índices de Gravidade do Trauma , Traumatismos Oculares/diagnóstico , Traumatismos Oculares/fisiopatologia , Prognóstico , Chile , Traumatismos Oculares/terapia , Valor Preditivo dos Testes , Estudos Retrospectivos , Seguimentos , Estudos Longitudinais , Emergências , Serviços de Saúde Ocular
3.
Rev. bras. oftalmol ; 79(1): 6-11, Jan.-Feb. 2020. tab, graf
Artigo em Inglês | LILACS | ID: biblio-1092657

RESUMO

Abstract Purpose: To assess long, intermediate and near uncorrected visual acuity after a tetrafocal diffractive intraocular lens implantation, presence of dystopic phenomenon and patient satisfaction after surgery. Methods: Retrospective, observational study performed in Puerta de Hierro Specialties Hospital, in Jalisco, México. That included 100 eyes after phacoemulsification surgery by femtosecond assistance, followed by tetrafocal diffractive intraocular lens implantation due to cataract. Long, intermediate and near visual acuity without correction was measured, and presence or absence of dystopic phenomenon, plus patient satisfaction after surgery. Results: A total of 100 eyes in 50 patients who underwent cataract surgery with phacoemulsification by femtosecond assistance were evaluated. 100% underwent bilateral phacoemulsification. Long, intermediate, and near visual acuity after three months was in the most patients 20/20 (46%), 20/15 (44%) and Jaeger 1 (48%) respectively. The percentage or patients who refers halos was 7%; and other associated symptoms in 18%, being astenopia the most prevalent. The removal of the lens was not required in any case. Conclusion: Tetrafocal diffractive intraocular lenses provides excellent intermediate vision (at 60 centimeters) and satisfactory near (30 centimeters) and long (6 meters) visual acuity.


Resumo Objetivo: Avaliar a acuidade visual de longe, intermediária e de perto após o implante de lente intra-ocular difrativa tetrafocal, presença de fenômenos distópicos e satisfação do paciente após a cirurgia. Métodos: Estudo retrospectivo, observacional, realizado em Puerta de Hierro Hospital de Especialidades, em Jalisco, México. Isso incluiu 100 olhos após a cirurgia de facoemulsificação pela presença de laser de femtosegundo, seguida por implante de lente intra-ocular difrativa tetrafocal devido à catarata ou cirurgia facorrefractiva. Foi medida a acuidade visual de longe, intermediária e de perto, e a presença ou ausência de fenômenos distópicos, além da satisfação do paciente após a cirurgia. Resultados: Um total de 100 olhos em 50 pacientes submetidos à cirurgia de catarata com facoemulsificação por femtosegundo foram avaliados. 100% foram submetidos a facoemulsificação bilateral. A acuidade visual para longe, intermediária e de perto após três meses foi na maioria dos pacientes 20/20 (46%), 20/15 (44%) e Jaeger 1 (48%) respectivamente. A porcentagem ou pacientes que se referem a halos foi de 7%; e outros sintomas associados em 18%, sendo a astenopia a mais prevalente. A remoção da lente não foi necessária em nenhum caso. Conclusão: A lente intra-ocular difrativa tetrafocal fornece excelente visão intermediária (a 60 centímetros) e acuidade visual satisfatória de perto a (30 centímetros) e de longe (6 metros).


Assuntos
Humanos , Masculino , Feminino , Adulto , Pessoa de Meia-Idade , Idoso , Facoemulsificação/métodos , Implante de Lente Intraocular/métodos , Lentes Intraoculares , Presbiopia/cirurgia , Presbiopia/diagnóstico , Refração Ocular/fisiologia , Catarata/diagnóstico , Acuidade Visual/fisiologia , Estudos Retrospectivos , Resultado do Tratamento , Satisfação do Paciente , Estudo Observacional
4.
Arq. bras. oftalmol ; 82(6): 463-470, Nov.-Dec. 2019. tab, graf
Artigo em Inglês | LILACS | ID: biblio-1038693

RESUMO

ABSTRACT Purpose: To evaluate the impact of visual acuity, visual field damage, and other factors on the quality of life in Brazilian patients with glaucoma. Methods: This cross-sectional prospective study involved 49 patients with glaucoma enrolled based on the presence of reproducible standard automated perimetry defects in at least one eye at the time of evaluation. A detailed ophthalmologic examination was performed on each patient. All patients had reproducible standard automated perimetry and completed an NEI VFQ-25 questionnaire. The associations of the quality of life scores to the best-corrected visual acuity and the visual field loss of the better and worse eyes were investigated. Results: The mean quality of life score of the patients was 58.8 ± 18.7 units. The highest and lowest mean values (85.0 ± 24.2 and 37.5 ± 36.5 units) were observed in the "Social Functioning Subscale" and "Driving Subscale," respectively. Patients with advanced glaucoma (mean deviation <-12 dB) in the worse eye had significantly lower quality of life scores (p=0.007). There was a significant correlation between the quality of life scores and the visual acuity of the better and worse eyes (r2=13%, p=0.010 and r2=32%, p<0.001, respectively). There was also a significant correlation between the quality of life scores and standard automated perimetry mean deviation of the better and worse eyes (r2=13%, p=0.023 and r2=47%, p<0.001, respectively). In a multivariate model containing so­cioeconomic and comorbidity indices, quality of life remained significantly related to the standard automated perimetry mean deviation of the better and worse eyes (r2=23%, p=0.29 and r2=49%, p<0.001, respectively) as well as to the visual acuity of the better and worse eyes (r2=18%, p=0.017 and r2=40%, p<0.001, respectively). Conclusion: The standard automated perimetry mean deviation and the visual acuity of the better and worse eyes were associated with lower quality of life in Brazilian patients with glaucoma. Quality of life was mostly highly associated with the standard automated perimetry mean deviation of the worse eye.


RESUMO Objetivo: Avaliar o impacto da acuidade visual, danos no campo visual e outros fatores na qualidade de vida em pacientes brasileiros com glaucoma. Métodos: Este foi um estudo transversal prospectivo incluindo 49 pacientes com glau­coma selecionados com base na presença de defeitos por perimetria automatizada padrão reprodutíveis em pelo menos um olho no momento da avaliação. Um exame oftalmológico detalhado foi realizado em cada paciente. Todos os pacientes possuíam perimetria automatizada padrão reprodutível e preencheram um questionário NEI VFQ-25. As associações dos escores de qualidade de vida à acuidade visual melhor corrigida e à perda de campo visual dos melhores e piores olhos foram investigadas. Resultados: A média dos escores de qualidade de vida dos pacientes foi de 58,8 ± 18,7 unidades. Os maiores e menores valores médios (85,0 ± 24,2 e 37,5 ± 36,5 unidades) foram observados nas subescalas "Social Functioning Subscale" e "Driving Subscale", respectivamente. Pacientes com glaucoma avançado (desvio médio <-12 dB) no pior olho tiveram escores de qualidade de vida significativamente menores (p=0,007). Houve correlação significativa entre escores de qualidade de vida e a acuidade visual dos olhos melhores e piores (r2=13%; p=0,010 e r2=32%; p<0,001; respectivamente). Houve também uma correlação significativa entre os escores de qualidade de vida e desvios médios da perimetria automatizada padrão dos olhos melhores e piores (r2=13%; p=0,023 e r2=47%; p<0,001; respectivamente). Em um modelo multivariado contendo dados socioeconômicos e de comorbidades, a qualidade de vida permaneceu significativamente relacionada ao desvio médio padrão da perimetria automatizada do olho melhor e pior (r2=23%; p=0,29 e r2=49%; p<0,001, respectivamente) bem como para a acuidade visual do olho melhor e pior (r2=18%; p= 0,017 e r2=40%; p<0,001, respectivamente). Conclusão: O desvio padrão da perimetria automatizada padrão e a acuidade visual dos olhos melhor e pior foram associados à menor qualidade de vida em pacientes brasileiros com glaucoma. A qualidade de vida foi em grande parte altamente associada ao desvio padrão da perimetria automatizada padrão do pior olho.


Assuntos
Humanos , Masculino , Feminino , Pessoa de Meia-Idade , Idoso , Qualidade de Vida , Acuidade Visual/fisiologia , Campos Visuais/fisiologia , Glaucoma/fisiopatologia , Valores de Referência , Fatores Socioeconômicos , Brasil , Modelos Lineares , Estudos Transversais , Estudos Prospectivos , Inquéritos e Questionários , Testes de Campo Visual , Pressão Intraocular
5.
Arq. bras. oftalmol ; 82(3): 189-194, May-June 2019. tab, graf
Artigo em Inglês | LILACS | ID: biblio-1001312

RESUMO

ABSTRACT Purpose: The purpose of this study was to objectively assess the optical vision quality of patients before and after Nd:YAG capsulotomy for posterior capsular opacification using a double-pass retinal imaging system. Methods: We retrospectively analyzed the data from 26 pseudophakic eyes with posterior capsular opacification that underwent Nd:YAG capsulotomy. The objective scatter indices, modulation transfer function cutoff frequencies, Strehl ratios, and logMAR corrected distance visual acuities were assessed before and after YAG capsulotomy with a double-pass retinal imaging system (OQAS II, Visiometrics, Spain). We also analyzed data from a subgroup of 10 patients with pre-YAG corrected distance visual acuity of 0.10 logMAR (20/25) or better. Results: Vision quality indices improved in all 26 eyes, resulting in a statistically significant improvement in the corrected distance visual acuity (p=0.007), objective scatter index (p=0.001), modulation transfer function cutoff frequency (p=0.001), and Strehl ratio (p=0.020). The overall mean improvements included 0.12 ± 0.04 logMAR for corrected distance visual acuity, 2.84 ± 0.76 for objective scatter index, 12.29 ± 2.77 for modulation transfer function cutoff frequency, and 0.06 ± 0.03 for Strehl ratio. Our sub-analysis of 10 eyes with 0.10 logMAR (20/25) corrected distance visual acuity or better also showed a statistically significant improvement in the mean objective scatter index (0.76 ± 16; p=0.001), resulting in approximately 35% decrease in intraocular light scatter. Conclusions: The objective vision quality measurements as assessed by the double-pass retinal imaging system showed a significant improvement after YAG capsulotomy. This suggests that the objective scatter index improves after YAG capsulotomy, even in eyes with pre-YAG 0.10 logMAR (Snellen 20/25) corrected distance visual acuity or better.


RESUMO Objetivo: Avaliar objetivamente a qualidade da visão óptica antes e depois da capsulotomia com Nd: YAG, obtida por imagem pelo metodo de dupla passagem de luz em pacientes com opacificação capsular posterior. Método: Análise retrospectiva de 26 olhos pseudofácicos com opacificação capsular posterior visualmente significativa, que foram submetidos à capsulotomia de Nd: YAG. O índice de dispersão objetiva, a função de transferência de modulação, a relação de Strehl e a acuidade visual à distância corrigida foram avaliados antes e após a capsulotomia com YAG usando o dupla passagem de luz (OQAS II, Visiometrics, Espanha). Também foi analisado um subgrupo de pacientes com acuidade visual à distância corrigida pré-YAG de 0,10 logMAR (20/25) ou melhor. Resultados: Os índices de qualidade da visão melhoraram em todos os 26 olhos, resultando em uma melhora estatisticamente significativa na acuidade visual à distância corrigida (p=0,007), índice de dispersão objetiva (p=0,001), função de transferência de modulação (p=0,001) e relação de Strehl (p=0,020). A melhora média na acuidade visual à distância corrigida foi de 0,12 ± 0,04 logMAR, no índice de dispersão objetiva foi de 2,84 ± 0,76, no função de transferência de modulação foi de 12,29 ± 2,77 e na razão de Strehl foi de 0,06 ± 0,03 em todos os olhos. Sub-análise de 10 olhos com 0.10 logMAR (20/25) acuidade visual à distância corrigida ou melhor também mostrou uma melhora estatisticamente significativa no índice de dispersão objetiva (p=0,001). A melhora média no OSI foi de 0,76 ± 16, uma diminuição de 35% na dispersão da luz intraocular. Conclusões: A qualidade da visão avaliada pelo dupla passagem de luz mostra uma melhora significativa nas medidas objetivas da qualidade da visão após a capsulotomia do YAG. O índice de dispersão objetiva melhora após a capsulotomia YAG, mesmo em olhos com acuidade visual à distância corrigida pré-YAG de 0,10 logMAR (Snellen 20/25) ou melhor.


Assuntos
Humanos , Masculino , Feminino , Idoso , Acuidade Visual/fisiologia , Pseudofacia/fisiopatologia , Opacificação da Cápsula/fisiopatologia , Capsulotomia Posterior/reabilitação , Valores de Referência , Retina/fisiopatologia , Retina/diagnóstico por imagem , Estudos Retrospectivos , Resultado do Tratamento , Pseudofacia/diagnóstico por imagem , Lasers de Estado Sólido/uso terapêutico , Opacificação da Cápsula/diagnóstico por imagem , Capsulotomia Posterior/métodos
6.
Rev. cuba. oftalmol ; 32(1): e706, ene.-mar. 2019. tab, graf
Artigo em Espanhol | LILACS | ID: biblio-1093674

RESUMO

RESUMEN Objetivo: Evaluar la repercusión de la cirugía de catarata por facoemulsificación en el mejoramiento de la discapacidad visual, la calidad de vida relativa a la visión y las actividades básicas de la vida diaria de adultos mayores. Métodos: Se realizó un estudio observacional, longitudinal y prospectivo en 108 pacientes intervenidos de catarata mediante la técnica facochop y el implante de lente intraocular, en el Instituto Cubano de Oftalmología Ramón Pando Ferrer, para determinar la calidad de vida relativa a la visión y la capacidad funcional antes y después de la cirugía. Se utilizaron los cuestionarios índice de función visual VisQoL-15 e índice de Katz. Se analizó la agudeza visual pre y posoperatoria con corrección, la calidad de vida relativa a la visión y el nivel de independencia para la realización de actividades de la vida diaria. Los resultados se volcaron en tablas de distribución de frecuencias absolutas, relativas y medias. La prueba de X2 determinó la relación entre las variables. Resultados: La agudeza visual mejor corregida posoperatoria mejoró 5 líneas en la cartilla de Snellen. El 99,7 por ciento de los pacientes consideró tener una muy buena y buena calidad de vida relativa a la visión luego de la cirugía. El incremento en la agudeza visual mejor corregida conllevó una mejoría en la calidad de vida relativa a la visión y el nivel de independencia. Conclusiones: La catarata provoca una considerable discapacidad visual y la facoemulsificación con implante de lente intraocular es un método efectivo y seguro para mejorar la calidad de vida relativa a la visión y la capacidad funcional en operados de catarata. El índice de función visual visqol-15 y el índice de Katz constituyen instrumentos útiles para determinar la calidad de vida relativa a la visión y la funcionalidad posterior a la cirugía de catarata(AU)


ABSTRACT Objective: To evaluated the impact of cataract surgery by phacoemulsification in the improvement of visual disability, quality of life relative to vision, quality of life and basic daily activities in senior adults. Methods: A longitudinal, prospective and observational study was made in 108 patients that underwent to cataract surgery with Faco-chop technique and IOL implantation in ICO Ramón Pando Ferrer to determinate the quality of life relative to vision (QLRV) and the functional capacity in patients before and after phacoemulsification. We evaluated by using the VisQol-15 questionnaire and Katz index. Visual acuity with and without correction, quality of life, and independence´s degree for daily life activities was taken and analyzed during the preoperative and postoperative. The results were overturned in graphics and tables of relative and absolutes frequencies. X2 test determined the relationship between variables. Results: The Best Corrected Visual Acuity (BCVA) gains 5 lines in Snellen chart. 99,7 percent of patients considered have a Good and Very Good QLRV after surgery. An increment of the independence´s degree for daily life activities and of QLRV was showed as well the BCVA increase. Conclusions: Cataract caused visual disability, phacoemulsification with IOL implant is an effective and safety method to improved QLRV and functional capacity in patients that underwent to cataract surgery. VisQol-15 and Katz index are useful instruments to determinate QLRV and functionality after phacoemulsification(AU)


Assuntos
Humanos , Masculino , Feminino , Idoso , Qualidade de Vida , Acuidade Visual/fisiologia , Facoemulsificação/métodos , Estudos Prospectivos , Estudos Longitudinais , Estudos Observacionais como Assunto
7.
Rev. bras. oftalmol ; 78(2): 127-129, mar.-abr. 2019. graf
Artigo em Inglês | LILACS | ID: biblio-1003566

RESUMO

Abstract Objective: To describe the outcomes in terms of near visual acuity and quality of life in 10 patients submitted to Scharioth Macular Lens implantation. Setting: João Eugênio Eye Institute, Brasilia, Brazil. Design: Uncontroled clinical trial. Methods: Ten pseudophakic patients with DMRI were submitted to the implantation of intraocular SML in the dominant eye in the period of December of 2017 to the March of 2018. All the patients had answered the Low-Vision Quality of Life Questionaire (LVQOLQ) before and after the surgery, with interval of 30 days. Results: The results points showed a statistical significant improvement (p<0.001) in the near visual acuity (NVA), without interference in the distance vision. All patients had significant improvements (p<0,05) in LVQOLQ on the item that evaluates the near visual acuity. Conclusion: There was an improvement of NVA in all 10 patients, as well as an enhancement to the quality of life in the postoperative period when compared to the preoperative period.


Resumo Objetivo: Descrever os resultados em termos de acuidade visual para perto e qualidade de vida em 10 pacientes submetidos ao implante de Lentes Maculares Scharioth. Local: Clínica de Olhos João Eugênio, Brasilia, Brasil. Design: Ensaio clínico não controlado. Métodos: Dez pacientes pseudofácicos com DMRI foram submetidos ao implante de SML intraocular no olho dominante no período de dezembro de 2017 a março de 2018. Todos os pacientes responderam ao Questionário de Qualidade de Vida em Baixa Visão (LVQOLQ) antes e após a cirurgia, com intervalo de 30 dias. Resultados: Os pontos de resultados mostraram uma melhora estatisticamente significativa (p <0,001) na acuidade visual para perto (AVP), sem interferência na visão à distância. Todos os pacientes tiveram melhora significativa (p <0,05) no LVQOLQ no item que avalia a acuidade visual para perto. Conclusão: Houve melhora na AVP em todos os 10 pacientes, além de um aumento da qualidade de vida no período pós-operatório quando comparado ao período pré-operatório.


Assuntos
Humanos , Masculino , Feminino , Pessoa de Meia-Idade , Idoso , Idoso de 80 Anos ou mais , Implante de Lente Intraocular/métodos , Lentes Intraoculares , Degeneração Macular/cirurgia , Qualidade de Vida , Acuidade Visual/fisiologia , Inquéritos e Questionários , Resultado do Tratamento , Pseudofacia
8.
São Paulo med. j ; 137(1): 25-32, Jan.-Feb. 2019. tab
Artigo em Inglês | LILACS | ID: biblio-1004741

RESUMO

ABSTRACT BACKGROUND: Exudative age-related macular degeneration (e-AMD) may cause severe central vision loss. Patients with e-AMD can experience difficulties in daily basic activities and suffer from psychological problems. Our aim was to assess quality of life (QoL) and anxiety and depression status among patients with e-AMD. DESIGN AND SETTING: Cross-sectional study in a state university. METHODS: We included 200 e-AMD patients and 120 age and gender-matched controls. We assessed QoL using the National Eye Institute Visual Functioning Questionnaire-25 (NEI-VFQ-25) and the Short Form (SF)-36 test; and anxiety and depression status using the Hospital Anxiety Depression Scales A and D (HADS-A and HADS-D). RESULTS: The mean ages in the e-AMD and control groups were 68.40 ± 9.8 and 66.31 ± 8.98, respectively. Visual acuity among e-AMD patients was 0.37 ± 0.31 and 0.39 ± 0.32 in the right and left eyes, respectively. The e-AMD patients performed significantly worse than the controls in NEI-VFQ-25 (P < 0.05 for all items). The proportions of e-AMD patients scoring higher than the cutoffs in HADS-A and HADS-D were significantly higher than among the controls (41.5% versus 12.5% and 63.5% versus 27.5%; P < 0.001). The e-AMD patients had significantly lower mean scores than the controls for each of the SF-36 QoL items (P < 0.001). The NEI-VFQ-25 scores were significantly lower among patients with bilateral e-AMD than among those with unilateral disease (P < 0.05 for all). The HADS scores were positively correlated with duration of e-AMD and patient age, but negatively with vision levels (P < 0.05 for all items). CONCLUSION: The e-AMD patients had higher depression and anxiety scores and lower QoL scores.


Assuntos
Humanos , Masculino , Feminino , Pessoa de Meia-Idade , Idoso , Ansiedade/fisiopatologia , Qualidade de Vida/psicologia , Depressão/fisiopatologia , Degeneração Macular/fisiopatologia , Degeneração Macular/psicologia , Ansiedade/psicologia , Valores de Referência , Fatores Socioeconômicos , Testes Visuais/métodos , Índice de Gravidade de Doença , Acuidade Visual/fisiologia , Estudos de Casos e Controles , Estudos Transversais , Inquéritos e Questionários , Estatísticas não Paramétricas , Perfil de Impacto da Doença , Depressão/psicologia
9.
Braz. j. infect. dis ; 22(3): 159-165, May-June 2018. tab, graf
Artigo em Inglês | LILACS | ID: biblio-974215

RESUMO

ABSTRACT Tuberculosis is an infectious disease of global importance with major economic and social burden accounting for 25% of all avoidable deaths in developing countries. Extrapulmonary involvement may occur either in association with clinically apparent pulmonary tuberculosis or in isolation. This cross-sectional descriptive study aimed to evaluate the impact of ocular tuberculosis in visual acuity at baseline and after two months of intensive anti-tuberculous therapy. A sample of 133 pulmonary tuberculosis patients, seven disseminated tuberculosis, and three pleural tuberculosis patients was evaluated. All patients underwent routine ophthalmic evaluation, including assessment of visual acuity, biomicroscopy, applanation tonometry, indirect ophthalmoscopy, and fluorescent angiography as appropriate. None of the patients had impaired visual acuity due to tuberculosis. A rate of 4.2% (6/143) of ocular involvement was found. None of the patients with ocular involvement were HIV-infected. Of the six patients with ocular involvement, five met the diagnostic criteria for probable and one for possible ocular lesions. As for the type of ocular lesions, two patients had bilateral findings: one had sclerouveitis and the second had choroidal nodules. The other four patients presented with unilateral lesions: peripheral retinal artery occlusion in the right eye (one case), choroidal nodules in the left eye (one case), and choroidal nodules in the right eye (two cases). Patients progressed favorably after two month of intensive therapy, with no significant reduction in vision.


Assuntos
Humanos , Masculino , Feminino , Adolescente , Adulto , Pessoa de Meia-Idade , Idoso , Adulto Jovem , Visão Ocular/fisiologia , Acuidade Visual/fisiologia , Tuberculose Ocular/fisiopatologia , Tuberculose Ocular/tratamento farmacológico , Antituberculosos/uso terapêutico , Pirazinamida/uso terapêutico , Rifampina/uso terapêutico , Transtornos da Visão/fisiopatologia , Transtornos da Visão/microbiologia , Tuberculose Ocular/complicações , Estudos Transversais , Resultado do Tratamento , Estatísticas não Paramétricas , Etambutol/uso terapêutico , Isoniazida/uso terapêutico
10.
Arq. bras. oftalmol ; 80(3): 159-164, May-June 2017. tab, graf
Artigo em Inglês | LILACS | ID: biblio-888107

RESUMO

ABSTRACT Purpose: To determine the vision status, ophthalmic findings, and quality of life among the very elderly. Methods: This was a cross-sectional observational study of individuals aged 80 years and above. A comprehensive ophthalmic exam was performed with mea surement of both the presenting (PVA) and best-corrected visual acuity. The Quality of Life Short Form-36 (SF-36) and the Visual Function Questionnaire (VFQ-25) were also administered. Results: A total of 150 non-institutionalized participants were assigned to three age groups: 80-89 years (n=70), 90-99 years (n=50), and 100 years and older (n=30). PVA and best-corrected visual acuity were normal (≥20/30) in 20 (13.3%) and 37 participants (24.7%), respectively. Regarding PVA, mild visual impairment (<20/30 to ≥20/60) was found in in 53 (35.4%), moderate visual impairment (<20/60 to ≥20/200) in 50 (33.3%), severe visual impairment (<20/200 to ≥20/400) in 8 (5.3%), and blindness (<20/400) in 19 (12.7%) participants. Regarding best-corrected visual acuity, mild, moderate, and severe visual impairments were present in 55 (36.7%), 38 (25.3%), and 5 (3.3%) participants, respectively, and blindness was present in 15 (10%). The main causes of visual impairment/blindness were cataract (43.8%), refractive errors (21.5%), age-related macular degeneration (17.7%), and myopic degeneration (3.8%). SF-36 scores were worse in those with low visual acuity, while VFQ-25 domain scores were poorer in those with vision impairment/blindness. Conclusion: Vision impairment and blindness was present in three-quarters of this sample, but it was notable that adequate correction with spectacles improved visual acuity. This reinforces the need for regular ophthalmic care in elderly patients to improve their quality of life by optimizing vision.


RESUMO Objetivos: Determinar a visão, achados oftalmológicos e qualidade de vida em longevos. Métodos: Estudo observacional transversal em indivíduos com idade entre 80 anos ou mais. Realizado exame oftalmológico com medida da acuidade visual apresentada e da acuidade visual melhor corrigida. Foram administrados os questionários: Qualidade de Vida Forma Curta - 36 (SF-36) e Qualidade de Função Visual (VFQ-25). Resultados: Total de 150 indivíduos não-institucionalizados foram estudados, divididos em três faixas etárias: 80 a 89 anos (n=70); 90 a 99 anos (n=50) e 100 anos ou mais (n=30). Acuidade visual apresentada normal (≥20/30) foi encontrada em 20 (13,3%) participantes; deficiência visual leve (<20/30 a ≥20/60), em 53 (35,4%); deficiência visual moderada (< 20/60 a ≥20/200) em 50 (33,3%); deficiência visual grave (<20/200 para ≥20/400) em 8 (5,3%) e cegueira (<20/400) em 19 (12,7%). A acuidade visual com a melhor correção aumentou para 37 (24,7%) indivíduos normais; deficiência leve aumentou para 55 (36,7%); deficiência visual moderada diminuiu para 38 (25,3%); deficiência visual grave foi reduzida para 5 (3,3%) e cegueira foi reduzida para 15 (10%). As principais causas de deficiência visual/cegueira foram: catarata (43,8%) erro refrativo (21,5%), degeneração macular relacionada à idade (17,7%), e degeneração miópica (3,8%). A pontuação no Questionário de Qualidade de Vida foi pior naqueles com baixa visão para perto. No questionário VFQ -25 os domínios com menor pontuação ocorreram nos indivíduos com baixa visão/cegueira. Conclusão: Deficiência visual/cegueira mostrou-se presente em três quartos desta amostra de longevos. A prescrição de óculos adequados proporcionou melhora da acuidade visual, reforçando a necessidade de atendimento oftalmológico regular desses pacientes para assegurar a qualidade de vida e de visão.


Assuntos
Humanos , Masculino , Feminino , Idoso de 80 Anos ou mais , Qualidade de Vida , Transtornos da Visão/fisiopatologia , Transtornos da Visão/epidemiologia , Acuidade Visual/fisiologia , Avaliação Geriátrica/métodos , Transtornos da Visão/etiologia , Brasil/epidemiologia , Envelhecimento/fisiologia , Prevalência , Estudos Transversais , Inquéritos e Questionários , Fatores Etários , Estatísticas não Paramétricas , Oftalmopatias/fisiopatologia , Oftalmopatias/epidemiologia
11.
Arq. bras. oftalmol ; 79(6): 376-379, Nov.-Dec. 2016. tab
Artigo em Inglês | LILACS | ID: biblio-838756

RESUMO

ABSTRACT Purpose: To evaluate the long-term outcomes of medically or surgically treated patients with atopic keratoconjunctivitis (AKC). Methods: Charts of 16 patients with AKC (32 eyes) observed between 1996 and 2013 were reviewed retrospectively. Outcome measures included demographic features, follow-up duration, and biomicroscopic findings at the first and most recent visits. The corrected distance visual acuity (CDVA; in decimal units) was evaluated at the initial visit and the 1-, 6-, and 12-month follow-up visits. Results: In the medically treated group (25 eyes of 15 patients), the median follow-up duration was 3 (range, 1-9) years, and the median CDVA values were 0.01 (0.001-1.0) at the first visit and 0.01 (0.001-0.8) at the most recent visit (p=0.916). In the penetrating keratoplasty (PK) group (7 eyes of 6 patients), the median follow-up duration was 7 years (range, 1-11), and the median CDVA increased from 0.01 (0.001-0.01) to 0.2 (0.001-0.7) postoperatively (p=0.043). Conclusion: Whereas most AKC patients maintained a useful CDVA with medical treatment, PK may be required in some cases. Despite the frequent occurrence of complications, PK can significantly improve the CDVA.


RESUMO Objetivo: Avaliar os resultados a longo prazo em ceratoconjuntivite atópica (AKC) pacientes que foram tratados clinicamente ou cirurgicamente. Métodos: Os prontuários de 16 pacientes (32 olhos) com AKC, que foram acompanhados entre 1996 e 2013 foram avaliados retrospectivamente. As medidas adotadas foram as características demográficas, tempos de seguimento, e resultados biomicroscópicos da visita inicial e da visita mais recente. A acuidade visual corrigida para distância (CDVA), apresentada em unidades decimais, foi avaliada na visita inicial e nas visitas do 1º mês, 6º mês e 1º ano de seguimento. Resultados: No grupo tratado clinicamente (25 olhos de 15 pacientes), a mediana do tempo de seguimento foi de 3 anos (variação, 1-9) e a CDVA média foi de 0,01 (0,001-1,0) na visita inicial e 0,01 (0,001-0,8) na visita mais recente (p=0,916). No grupo de ceratoplastia penetrante (PK) (7 olhos de 6 pacientes), a mediana de tempo de seguimento foi de 7 anos (variação, 1-11) e a CDVA média aumentou de 0,01 (0,001-0,01) para 0,2 (0,001-0,7) (p=0,043) no pós-operatório. Conclusões: Embora a maioria dos pacientes AKC mantém a CDVA útil com o tratamento clínico, alguns necessitam de PK a fim de obter CDVA útil. Embora as complicações pós-PK ocorrem com freqüência, a CDVA pode melhorar significativamente.


Assuntos
Humanos , Masculino , Feminino , Adolescente , Adulto , Idoso , Adulto Jovem , Conjuntivite Alérgica/terapia , Acuidade Visual/fisiologia , Ceratoplastia Penetrante , Ceratoconjuntivite/terapia , Conjuntivite Alérgica/cirurgia , Estudos de Casos e Controles , Estudos Retrospectivos , Seguimentos , Resultado do Tratamento , Avaliação de Resultados em Cuidados de Saúde , Ceratoconjuntivite/cirurgia
12.
Arq. bras. oftalmol ; 79(5): 299-302, Sept.-Oct. 2016. tab
Artigo em Inglês | LILACS | ID: biblio-827964

RESUMO

ABSTRACT Purpose: To compare the effect of 20% sulfur hexafluoride (SF6) with that of air on graft detachment rates for intraocular tamponade in Descemet membrane endothelial keratoplasty (DMEK). Methods: Forty-two eyes of patients who underwent DMEK by a single surgeon (A.S.J.) at Wilmer Eye Institute between January 2012 and 2014 were identified; 21 received air for intraocular tamponade and the next consecutive 21 received SF6. The main outcome measure was the graft detachment rate; univariate and multivariate analyses were performed. Results: The graft detachment rate was 67% in the air group and 19% in the SF6 group (p<0.05). No complete graft detachments occurred, and all partial detachments underwent intervention with injection of intraocular air. The percentages of eyes with 20/25 or better vision were not different between the groups (67% vs. 71%). Univariate analysis showed significantly higher detachment rates with air tamponade (OR, 8.50; p<0.005) and larger donor graft size (OR, 14.96; p<0.05). Multivariate analysis with gas but not graft size included showed that gas was an independent statistically significant predictor of outcome (OR, 6.65; p<0.05). When graft size was included as a covariate, gas was no longer a statistically significant predictor of detachment but maintained OR of 7.81 (p=0.063) similar to the results of univariate and multivariate analyses without graft size. Conclusion: In comparison with air, graft detachment rates for intraocular tamponade in DMEK were significantly reduced by 20% SF6.


RESUMO Objetivo: Comparar as taxas de descolamento do botão endotelial com o uso de gás hexafluoreto de enxofre a 20% (SF6) em relação ao ar para o tamponamento intraocular na ceratoplastia endotelial da membrana de Descemet (DMEK). Métodos: Quarenta e dois olhos foram operados com a técnica de DMEK por um único cirurgião (A.S.J.) no Wilmer Eye Institute entre janeiro de 2012 a 2014. Os primeiros 21 olhos receberam ar para o tamponamento intraocular após o enxerto do botão endotelial e os 21 olhos seguintes receberam SF6. O desfecho primário medido foi a taxa de descolamento do botão endotelial por análise univariada e multivariada. Resultados: A taxa de descolamento do botão endotelial foi de 67% no grupo que recebeu ar vs 19% no grupo que recebeu SF6 (p<0,05). Não houve nenhum descolamento total de botão e todos os parciais foram tratados com injeção de ar intraocular. Não houve diferença estatística significativa entre os grupos em relação a AV de 20/25 ou melhor (67% vs 71%). A análise univariada demonstrou maior taxa de descolamento com o tamponamento por ar intraocular (OR 8,50, p<0,005) e com botões doadores maiores (OR 14,96, p<0,05). Na análise multivariada, incluindo gás, mas não o tamanho do botão doador, o tipo de gás usado permaneceu sendo um fator preditivo independente e estatisticamente significativo para o desfecho primário, com OR de 6,65 (p<0,05). Porém, quando o tamanho do botão doador foi incluso como covariável, o gás perdeu a sua significância como preditor de descolamento, mantendo o OR de 7,81 (p=0,063), semelhante as análises univariada e multivariada excluindo o tamanho do botão doador. Conclusão: O uso de gás hexafluoreto de enxofre a 20% (SF6) para o tamponamento intraocular reduz a taxa de descolamento do botão endotelial quando comparado ao uso de ar no DMEK.


Assuntos
Humanos , Masculino , Feminino , Pessoa de Meia-Idade , Idoso , Hexafluoreto de Enxofre/administração & dosagem , Endotélio Corneano/transplante , Lâmina Limitante Posterior/cirurgia , Ar , Ceratoplastia Endotelial com Remoção da Lâmina Limitante Posterior/métodos , Tamponamento Interno/métodos , Período Pós-Operatório , Fatores de Tempo , Acuidade Visual/fisiologia , Análise Multivariada , Estudos Retrospectivos , Seguimentos , Resultado do Tratamento , Rejeição de Enxerto , Sobrevivência de Enxerto , Pressão Intraocular
13.
Arq. bras. oftalmol ; 79(4): 233-237, July-Aug. 2016. tab, graf
Artigo em Inglês | LILACS | ID: lil-794584

RESUMO

ABSTRACT Purpose: To compare therapeutic outcomes between trabeculectomy and medical therapy in patients with open-angle glaucoma. Methods: In the present retrospective comparative study, the medical charts of 284 patients (eyes) newly diagnosed with open-angle glaucoma who had received conventional medications (n=188) or undergone fornix-based trabeculectomy (n=96) at a teaching eye hospital were reviewed. Results: At a mean follow-up of 6.6 years, post-treatment changes in intraocular pressure (IOP), visual field (VF), best spectacle-corrected visual acuity (BSCVA), and number of required drugs were significantly more favorable in the surgical group (P<0.001 for all comparisons). However, the frequency of clinically desirable IOP (≤21 mmHg) at the endpoint was comparable between the surgical and medical groups (87.2% vs. 82.3%; P=0.26). The rate of conversion to surgical therapy was 34% in the medical group. A greater baseline requirement for anti-glaucoma drugs (two or more) was the only independent predictor of treatment failure in the present study. Conclusions: Although more severe cases naturally receive trabeculectomy, the surgical approach had greater efficacy than conventional medical therapy in patients with open-angle glaucoma. An initial requirement for two or more anti-glaucoma drugs may predict failure of medical therapy.


RESUMO Objetivo: Comparar o resultado terapêutico de trabeculectomia versus terapia médica em pacientes com glaucoma de ângulo aberto. Método: Neste estudo comparativo retrospectivo, prontuários médicos de 284 pacientes (olhos), de um hospital de ensino oftalmológico, com diagnóstico recente de glaucoma de ângulo aberto que receberam medicamentos convencionais (n=188) ou foram submetidos a trabeculectomia de base fórnice (n=96) foram revisados. Resultados: Com seguimento médio de 6,6 anos, as mudanças pós-tratamento da pressão intraocular (PIO), campo visual (VF), melhor acuidade visual corrigida por óculos (BSCVA), e o número de medicações necessárias foram significativamente mais favorável ao grupo cirúrgica (p<0,001 para todas as comparações). No entanto, os grupos foram comparáveis para a frequência de PIO clinicamente desejável (≤21 mmHg) na visita final (87,2% vs. 82,3%, respectivamente; p=0,26). A taxa de conversão para o tratamento cirúrgico foi de 34% no grupo médico e a necessidade inicial de mais drogas antiglaucomatosas (2 ou mais) foi o único preditor independente desta conversão. Conclusões: Embora os casos mais graves de glaucoma são naturalmente designados o grupo de trabeculectomia, esta abordagem cirúrgica se mostrou mais eficaz do que a terapia médica convencional em pacientes com glaucoma de ângulo aberto. Uma necessidade inicial de 2 ou mais medicações antiglaucomatosas pode prever a falha em terapia médica.


Assuntos
Humanos , Masculino , Feminino , Adulto , Pessoa de Meia-Idade , Idoso , Idoso de 80 Anos ou mais , Trabeculectomia/métodos , Glaucoma de Ângulo Aberto/cirurgia , Glaucoma de Ângulo Aberto/tratamento farmacológico , Fatores de Tempo , Acuidade Visual/fisiologia , Campos Visuais/fisiologia , Estudos Retrospectivos , Curva ROC , Seguimentos , Resultado do Tratamento , Estatísticas não Paramétricas , Pressão Intraocular
14.
Arq. bras. oftalmol ; 79(3): 171-176, tab, graf
Artigo em Inglês | LILACS | ID: lil-787325

RESUMO

ABSTRACT Purpose: To compare the optical performance and visual outcomes between two diffractive multifocal lenses: AMO Tecnis® ZMB00 and AcrySof® ReSTOR® SN6AD1. Methods: This prospective, non-randomized comparative study included the assessment of 74 eyes in 37 patients referred for cataract surgery and candidates for multifocal intraocular lens implants. Exclusion criteria included existence of any other eye disease, previous eye surgery, high axial myopia, preoperative corneal astigmatism of >1.00 cylindrical diopter (D), and intraoperative or postoperative complications. Ophthalmological evaluation included the measurement of uncorrected distance visual acuity (UDVA), corrected distance visual acuity (CDVA), distance-corrected near visual acuity (DCNVA), and distance-corrected intermediate visual acuity (DCIVA), with analysis of contrast sensitivity (CS), wavefront, and visual defocus curve. Results: Postoperative UDVA was 0.09 and 0.08 logMAR in the SN6AD1 and ZMB00 groups, respectively (p=0.868); postoperative CDVA was 0.04 and 0.02 logMAR in the SN6AD1 and ZMB00 groups, respectively (p=0.68); DCIVA was 0.17 and 0.54 logMAR in the SN6AD1 and ZMB00 groups, respectively (p=0.000); and DCNVA was 0.04 and 0.09 logMAR in the SN6AD1 and ZMB00 groups, respectively (p=0.001). In both cases, there was an improvement in the spherical equivalent and UDVA (p<0.05). Under photopic conditions, the SN6AD1 group had better CS at low frequencies without glare (p=0.04); however, the ZMB00 group achieved better sensitivity at high frequencies with glare (p=0.003). The SN6AD1 and ZMB00 lenses exhibited similar behavior for intermediate vision, according to the defocus curve; however, the ZMB00 group showed a shorter reading distance than the SN6AD1 group. There were no significant differences regarding aberrometry between the two groups. Conclusion: Both lenses promoted better quality of vision for both long and short distances and exhibited a similar behavior for intermediate vision. The SN6AD1 and ZMB00 groups showed better results for CS under photopic conditions at low and high spatial frequencies, respectively.


RESUMO Objetivo: Comparar o desempenho óptico e resultado visual entre duas lentes multifocais difrativas: AMO Tecnis® ZMB00 e AcrySof® ReSTOR® SN6AD1. Métodos: O estudo prospectivo, comparativo não randomizado incluiu avaliação de 74 olhos em 37 pacientes com indicação de facectomia e candidatos a implante de lente multifocal. Critérios de exclusão foram: presença de outras doenças oculares; cirurgia ocular prévia; alta miopia axial; astigmatismo cornenano maior que 1,00 D cilíndrica; complicações intraoperatórias ou pós-operatórias. A avaliação oftalmológica contou com medida da acuidade visual para longe corrigida (CDVA) e não corrigida (UDVA), intermediária (DCIVA) e curta distância (DCNVA) com melhor correção óptica para longe; teste de sensibilidade ao contraste; análise de frente de onda e curva visual de Defocus. Resultados: A UDVA foi de 0,09 logMAR para o grupo SN6AD1 e 0,08 logMAR para o grupo ZMB00; com correção foi de 0,04 logMAR para SN6AD1 e 0,02 para o grupo ZMB00 (p>0,05). O grupo SN6AD1 obteve valor de 0,04 logMAR e o grupo ZMB00 de 0,09 logMAR para DCNVA (p<0,05) e DCIVA de 0,17 logMAR para SN6AD1 e 0,54 logMAR para ZMB00 (p=0,000). Houve melhora do equivalente esférico e da UDVA em ambos os grupos (p<0,05). Em condições fotópicas, o grupo SN6AD1 teve melhor sensibilidade ao contraste em baixas frequências sem ofuscamento (p<0,05), contudo grupo ZMB00 obteve melhor sensibilidade em altas frequências (p<0,05) com ofuscamento. As lentes SN6AD1 e ZMB00 obtiveram comportamento semelhantes para visão intermediária na curva de Defocus, porém, o grupo ZMB00 mostrou menor distância de leitura que o grupo SN6AD1. Não houve diferença com significância estatística relacionada à aberrometria na comparação dos dois grupos. Conclusão: As duas lentes promoveram melhor qualidade de visão para longe e perto e comportamento semelhante para visão intermediária. O grupo ZMB00 exibiu melhores resultados para sensibilidade ao contraste em condições fotópicas em alta frequência espacial e SN6AD1 em baixa frequência espacial.


Assuntos
Humanos , Masculino , Feminino , Pessoa de Meia-Idade , Idoso , Acuidade Visual/fisiologia , Implante de Lente Intraocular/métodos , Lentes Intraoculares , Período Pós-Operatório , Desenho de Prótese , Valores de Referência , Refração Ocular , Análise de Variância , Resultado do Tratamento , Aberrometria , Período Pré-Operatório
15.
Arq. bras. oftalmol ; 78(1): 40-43, Jan-Feb/2015. tab
Artigo em Inglês | LILACS | ID: lil-741155

RESUMO

Objective: To identify the causes of low visual acuity and systemic morbidities that limit ambulation and access to eye care in geriatric clinics in Rio de Janeiro. Methods: This cross-sectional study evaluated 187 patients from three geriatric clinics in Rio de Janeiro between January 2010 and January 2011. The inclusion criteria were individuals with a visual acuity of less than of equal to 20/200 in either eye (118 individuals), without optical correction. The exclusion criteria were individuals who refused to participate and those unable to undergo screening because of mental disabilities (6 individuals). Of the 187 individuals evaluated, 63 had visual acuity above 20/200. Results: A total of 118 individuals with a visual acuity of ≤20/200 effectively participated in the study after meeting the inclusion and exclusion criteria. In addition, 57 participants (48.3%) presented systemic disabling morbidities. Of the 118 individuals with low visual acuity, 27.96% had cataract and 26.27% had refractive errors. Conclusion: Most of the patients from geriatric clinics experienced ocular morbidities, but their proper treatment resulted in improved visual acuity. A more socially oriented problem associated with eye care involved the difficulty of access to ophthalmologic consultations. .


Objetivo: Identificar causas de baixa acuidade visual e morbidades sistêmicas que dificultem a deambulação e o acesso à tratamento oftalmológico em clínicas geriátricas do Rio de Janeiro. Métodos: Estudo transversal com 187 indivíduos de 3 clínicas geriátricas do Rio de Janeiro, no período de janeiro de 2010 à janeiro de 2011. O critério de inclusão foi todos os indivíduos com acuidade visual menor ou igual a 20/200 em qualquer olho (118 indivíduos) e sem atualização da correção óptica. O critério de exclusão foi indivíduos que se recusaram à participar do estudo e indivíduos incapazes de realizarem os exames por déficit mental (6 indivíduos). Dos 187 indivíduos avaliados, 63 indivíduos tinham acuidade visual melhor que 20/200. Resultados: Participaram do estudo efetivamente, após os critérios de inclusão e exclusão, 118 indivíduos com variadas causas de acuidade visual menor ou igual 20/200. Foram encontrados no estudo 57 (48,3%) indivíduos com a presença de morbidades sistêmicas incapacitantes. Dos 118 indivíduos com baixa acuidade visual, que participaram do estudo, 27,96% apresentaram catarata e 26,27% ametropias. Conclusão: A maioria dos indivíduos destas clínicas geriátricas apresentou morbidades oculares que com tratamento adequado permitem a melhora da acuidade visual. Foi encontrado um problema mais de cunho social pela dificuldade de acesso à consulta oftalmológica. .


Assuntos
Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Hospital Dia/estatística & dados numéricos , Pessoas com Deficiência/estatística & dados numéricos , Acessibilidade aos Serviços de Saúde/estatística & dados numéricos , Serviços de Saúde para Idosos/estatística & dados numéricos , Limitação da Mobilidade , Brasil/epidemiologia , Estudos Transversais , Catarata/complicações , Morbidade , Erros de Refração/complicações , Acuidade Visual/fisiologia
16.
Arq. bras. oftalmol ; 78(1): 19-22, Jan-Feb/2015. tab, graf
Artigo em Inglês | LILACS | ID: lil-741162

RESUMO

Purpose: To compare the efficiency of surgical procedures using three phaco tip designs in torsional phacoemulsification using the bevel-down technique. Methods: In this prospective, comparative, masked study, patients were randomly assigned to have torsional coaxial microincision cataract surgery using the mini-flared 45-degree Kelman tip, reversed mini-flared 30-degree Kelman tip, or Sidewinder 30-degree Kelman tip. Clinical measurements included preoperative and 3-month postoperative corrected distance visual acuity (CDVA), endothelial cell counts (ECC), and preoperative and 1-day postoperative central corneal thickness (CCT). Intraoperative measurements included phaco time, torsional time, aspiration time, case time, cumulative dissipated energy (CDE), and balanced salt solution volume (BSS). Results: The study evaluated 150 eyes of 150 patients. Intraoperatively, there was no statistically significant difference in cumulative dissipated energy, case time, torsional time, and aspiration time between the three tip configurations. However, less phaco time was used with the mini-flared 45-degree Kelman tip (p=0.02) than that with the Sidewinder 30-degree Kelman tip or reversed mini-flared 30-degree Kelman tip. The mini-flared 45-degree Kelman tip and the reversed mini-flared 30-degree Kelman tip required significantly less balanced salt solution volume than that required by the Sidewinder 30-degree Kelman tip (p=0.009). There was no statistically significant difference in corrected distance visual acuity and endothelial cell counts between tips 3 months postoperatively (p>0.05). Conclusion: All three tips were effective with no intraoperative complications. When using torsional phacoemulsification through microincisions and the prefracture technique with the bevel-down technique, the mini-flared 45-degree Kelman tip required a lower mean phaco time than the reversed mini-flared 30-degree Kelman tip and the Sidewinder 30-degree Kelman tip. .


Objetivo: Comparar a eficácia cirúrgica da facoemulsificação com tecnologia torcional utilizando 3 modelos diferentes de ponteiras. Métodos: Neste estudo prospectivo, randomizado, mascarado, os pacientes foram aleatoriamente distribuídos para serem submetidos a cirurgia de facoemulsificação coaxial torcional utilizando a ponteira Kelman mini-flared de 45 graus, ou Kelman reversed mini-flared de 30 graus ou Kelman Sidewinder de 30 graus. Os parâmetros avaliados incluíram: acuidade visual com correção (AVCC) para longe; contagem de células endoteliais (CCE) pré-operatória e pós-operatória, ao final de 3 meses; espessura corneana central (ECC) pré-operatória e no primeiro dia pós-operatório. Medidas intraoperatórias incluíram tempo de facoemulsificação, tempo de energia torcional, tempo da aspiração, tempo cirúrgico, energia dissipada acumulada (CDE) e volume de solução salina balanceada (BSS). Resultados: Este estudo avaliou 150 olhos de 150 pacientes. No intraoperatório, não foram observadas diferenças significativas na energia dissipada acumulada, tempo de facoemulsificação, tempo de energia torcional, e tempo de aspiração entre os 3 modelos de ponteira. No entanto, foi utilizando menos tempo de faco com a ponteira Kelman mini-flared de 45 graus (p=0,02) quando comparado às ponteiras Kelman Sidewinder de 30 graus e reversa mini-flared de 30 graus. A ponteira Kelman mini-flared de 45 graus e a reversa mini-flared de 30 graus utilizaram menos solução salina balanceada quando comparado à ponteira Sidewinder de 30 graus (p=0,009). Não foram observadas diferenças significativas na acuidade visual com correção, contagem de células endoteliais e espessura corneana central entre as diferentes ponteiras ao final do estudo (p=0,05). Conclusão: As 3 ponteiras foram eficazes e não apresentaram complicacões intraoperatórias. Quando foi utilizando o faco torcional através de microincisão com a técnica da pré-fratura, a ponteira Kelman mini-flared ...


Assuntos
Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Córnea/cirurgia , Facoemulsificação/instrumentação , Contagem de Células , Desenho de Equipamento , Endotélio Corneano/citologia , Período Intraoperatório , Duração da Cirurgia , Período Pós-Operatório , Cuidados Pré-Operatórios , Estudos Prospectivos , Facoemulsificação/métodos , Método Simples-Cego , Resultado do Tratamento , Acuidade Visual/fisiologia
17.
Rev. bras. oftalmol ; 73(2): 81-85, Mar-Apr/2014. tab, graf
Artigo em Português | LILACS | ID: lil-718429

RESUMO

Objetivo: Avaliar a função visual dos pacientes com implante bilateral da LIO multifocal difrativa AT-Lisa 809 MTM por meio dos exames de acuidade visual com e sem correção óptica, curva de sensibilidade ao contraste, curva de desfoco e questionário de qualidade de função visual (VQF39). Métodos: Estudo clínico, prospectivo e de intervenção, que avaliou os resultados de 20 olhos de 10 pacientes, submetidos à facoemulsificação e implante de LIO, entre fevereiro e junho de 2012. Resultados: A ametropia residual média pós-operatória foi de 0,05 ± 0,42 (-0,75 a +1,25 D) dioptrias esféricas e -0,30 ± 0,42 (0 a -1,25 D) dioptrias cilíndricas. Na curva de desenfoque mono e binocular, a melhor acuidade visual média obtida com 0.00 D de desenfoque (AV de longe). O segundo pico foi obtido com desenfoque de -3,00 D, o que equivale à visão de perto a 33 cm. Entre esses picos, observamos uma perda de desempenho visual, com desenfoque de -2,00 D, que equivale a visão intermediária a 50 cm. A sensibilidade ao contraste foi similar aos relatados na literatura com este tipo de LIO, tanto com quanto sem ofuscamento, e é mostrada em gráficos. O questionário de função visual (VFQ-39) teve valor médio de 91,91 +- 6,82. Conclusão: A LIO multifocal difrativa AT-Lisa 809MTM (Carl Zeiss Meditec Company - Alemanha) apresentou resultados condizentes com a literatura quando avaliada pelos exames de acuidade visual com e sem correção óptica, sensibilidade ao contraste, curva de desfoco e questionário de qualidade de função visual (VQF 39). .


Purpose: To evaluate the visual function of patients with bilateral implantation of multifocal diffractive IOL AT Lisa 809MTM by visual acuity with and without correction, contrast sensitivity curve, defocus curve and visual function questionnaire (39 VQF). Methods: Interventional clinical prospective study, which evaluated the results of 20 eyes of 10 patients who underwent phacoemulsification and IOL implantation between february and june 2012. Results: The average of residual postoperative ametropia was 0.05 ± 0.42 (-0.75 to +1.25 D) spherical diopters and -0.30 ± 0.42 (0 to -1.25 D) cylindrical diopters. In the mono and binocular defocus curve, the best visual acuity was obtained with 0.00 D of defocus (far VA). The second peak was obtained with -3.00 D (near vision at 33 cm) and among these peaks, it was observed a loss of visual performance with -2.00 D, which corresponds to intermediate vision at 50 cm. Contrast sensitivity was similar to those reported in the literature with this type of IOL, both with and without glare, and is shown in the figures. The visual function questionnaire (VFQ-39) had a mean value of 91.91 + - 6.82. Conclusion: The diffractive multifocal IOL-AT LISA 809M presented results consistent with the literature as measured by tests of visual acuity with and without optical correction, contrast sensitivity curve, defocus curve and visual function questionnaire (39 VQF). .


Assuntos
Humanos , Masculino , Feminino , Pessoa de Meia-Idade , Idoso , Implante de Lente Intraocular/métodos , Lentes Intraoculares Multifocais , Testes Visuais , Catarata , Atividades Cotidianas , Sensibilidades de Contraste/fisiologia , Visão Binocular , Visão Monocular , Acuidade Visual/fisiologia , Estudos Prospectivos , Inquéritos e Questionários , Biometria , Resultado do Tratamento , Satisfação do Paciente , Facoemulsificação/métodos , Óculos
18.
Rev. bras. oftalmol ; 73(2): 86-92, Mar-Apr/2014. tab, graf
Artigo em Português | LILACS | ID: lil-718428

RESUMO

Objetivo: Fornecer uma avaliação objetiva e subjetiva da qualidade de vida e o nível de satisfação de pacientes que se submeteram à cirurgia de catarata, com implante de lentes bifocais, multifocais e monofocais. Métodos: Lentes bifocais foram implantadas em 72 pacientes; lentes multifocais asférica em 16 pacientes; lentes multifocais apodizada em 20 pacientes e lentes monofocais em 63 pacientes. Foi aplicado um questionário de 47 perguntas cujos resultados foram avaliados e analisados. Resultados: O nível de satisfação dos pacientes implantados com lentes bifocais e multifocais foi significantemente mais alto do que aqueles com lentes monofocais (teste Kruskal-Wallis p<0,01, seguido do teste Dunn, p<0,05). Quanto à comparação de lentes monofocais com lentes bifocais e multifocais, a visão para perto sem correção foi consideravelmente mais baixa em pacientes com lentes monofocais (teste Z, p<0,001). Os pacientes com lentes monofocais sem correção apresentaram uma menor capacidade de ler jornais ou livros e no que diz respeito a trabalhos manuais do que aqueles com lentes bifocais e multifocais (teste Z, p<0,001). Conclusão: Os resultados deste estudo mostram que os pacientes que receberam as lentes bifocais e multifocais tiveram uma melhora notável em sua acuidade visual para perto, estando satisfeitos com sua visão geral, sem óculos. A satisfação foi atribuída ao fato de conseguirem ler livros e jornais, preencher cheques, preencher formulários, praticar esportes, se barbear ou se maquiar sem correção. .


Purpose: Providing an objective and subjective evaluation of life quality and satisfaction level of the patients who underwent cataract surgery with implant of bifocal, multifocal and monofocal lenses. Methods: Bifocal lenses were implanted in 72 patients, aspheric multifocal lenses in 16 patients, apodized multifocal lenses in 20 patients and Monofocal lenses were implanted in 63 patients. The patients answered a 47 question questionnaire, whose results were evaluated and analyzed. Results: The level of satisfaction of the patients implanted with bifocal and multifocal lenses was significantly higher than of those with monofocal lenses (kruskal - Wallis test, p< 0.001 followed by the Dunn test, p< 0.05). As to the comparison of monofocal lenses with bifocal and multifocal lenses, the near vision without correction was considerably lower in patients with monofocal lenses (Z test p< 0.001). The patients with monofocal lenses without correction presented a much lower capacity of reading newspapers or books and as far as manual work than the ones with bifocal and multifocal lenses (Z test, p<0.001). Conclusion: The result of this study shows that the patients who received the bifocal and multifocal lenses had a remarkable improvement in their visual acuity for the near vision, being pleased with their general vision without wearing glasses. This is because they were able to read books and newspapers, write checks, fill out forms, do sports, shave or put on make-up, hence having high quality of life without correction. .


Assuntos
Humanos , Masculino , Feminino , Pessoa de Meia-Idade , Idoso , Qualidade de Vida , Extração de Catarata , Lentes Intraoculares , Catarata , Atividades Cotidianas , Acuidade Visual/fisiologia , Inquéritos e Questionários , Satisfação do Paciente , Implante de Lente Intraocular , Óculos
19.
Arq. bras. oftalmol ; 77(2): 71-75, Mar-Apr/2014. tab, graf
Artigo em Inglês | LILACS | ID: lil-716265

RESUMO

Purpose: To assess the postoperative outcomes of a novel toric multifocal in traocular lens (IOL) in patients with cataract and corneal astigmatism. Methods: This prospective nonrandomized study included patients with cataract, corneal astigmatism, and a motivation for spectacle independence. In all patients, a Rayner M-flex® T toric IOL was implanted in the capsular bag. Three months after surgery, the distance, intermediate, and near visual acuities; spherical equivalent; residual refractive astigmatism; defocus curve; and contrast sensitivity were evaluated. A patient satisfaction and visual phenomena questionnaire was administered to all patients. Results: Thirty-four eyes of 18 patients were included in this study. Three months after surgery, the mean corrected distance visual acuity (logMAR) was 0.00 ± 0.08 at 6 m, 0.20 ± 0.09 at 70 cm, and 0.08 ± 0.11 at 40 cm. Uncorrected distance vision acuity was 20/40 or better in 100% eyes. The preoperative mean refractive cylinder (RC) was -2.19 (SD: ± 0.53). After a 3-month follow-up, the average RC was -0.44 D (SD: ± 0.27; p<0.001). Contrast sensitivity levels were high. At the last follow-up, 87.5% patients were spectacle-independent for near, intermediate, and distance vision, and approximately 44% patients reported halos and glare. Conclusion: Toric multifocal IOL implantation in patients with cataract and corneal astigmatism using the Rayner M-flex® T toric IOL was a simple, safe, and accurate option. This technology provides surgeons with a feasible option for meeting patient expectations of an enhanced lifestyle resulting from decreased spectacle dependence. .


Objetivo: Avaliar o resultado pós-operatório de uma nova lente intraocular (LIO) multifocal tórica implantada em pacientes com catarata e astigmatismo corneano. Métodos: Estudo prospectivo não randomizado envolvendo pacientes com catarata, astigmatismo corneano, e motivação para eliminar a dependência dos óculos. Em todos os casos, a lente intraocular tórica Rayner M-flex® T foi implantada dentro do saco capsular. Três meses pós-operatório foram avaliados: acuidade visual para longe, intermediário e perto; equivalente esférico; astigmatismo refracional residual; curva de defocus e sensibilidade ao contraste. Ao final do estudo um questionário referente à satisfação visual foi aplicado. Resultados: Trinta e quatro olhos de 18 pacientes foram incluídos no estudo. Após 3 meses de pós-operatório, a acuidade visual corrigida para longe (logMAR) era de 0,00 ± 0,08 a 6 m, 0,20 ± 0,09 a 70 cm e 0,08 ± 0,11 a 40 cm. A acuidade visual sem correcão foi de 20/40, ou melhor, em 100% dos olhos. A média do cilindro refracional pré-operatório era de -2,19 (DP: ± 0,53). Após o seguimento de 3 meses a média do cilindro refracional era de -0,44 D (DP: ± 0,27) (p<0,001). Os níveis de sensibilidade ao contraste foram elevados. Ao final do seguimento, 87,5% dos pacientes estavam independentes dos óculos para perto, intermediário e para longe, e aproximadamente 44% dos pacientes relatavam halos e glare. Conclusão: O implante de uma lente intraocular multifocal em pacientes com catarata e astigmatismo corneano utilizando a lente intraocular tórica Rayner M-flex® T foi uma opção simples, segura e acurada. Essa nova tecnologia oferece ao cirurgião uma maneira passível de se atingir as expectativas dos pacientes em relação ...


Assuntos
Idoso , Feminino , Humanos , Masculino , Astigmatismo/cirurgia , Extração de Catarata/métodos , Catarata/complicações , Lentes Intraoculares , Implante de Lente Intraocular/métodos , Astigmatismo/complicações , Catarata/fisiopatologia , Sensibilidades de Contraste/fisiologia , Satisfação do Paciente , Estudos Prospectivos , Resultado do Tratamento , Acuidade Visual/fisiologia
20.
Arq. bras. oftalmol ; 76(4): 233-236, jul.-ago. 2013. graf, tab
Artigo em Português | LILACS | ID: lil-686560

RESUMO

OBJETIVOS: Comparar a acuidade visual dos pacientes que foram submetidos à facoemulsificação com implante de LIO AcrySof® tórica versus LIO AcrySof® IQ e avaliar a redução da dioptria cilíndrica (DC) pós-operatória. MÉTODOS: Estudo analítico retrospectivo de 149 olhos submetidos à cirurgia de catarata por facoemulsificação, com astigmatismo ceratométrico regular, simétrico, com 1 dioptria ou mais. Foram divididos em dois grupos. O grupo tórica com 85 olhos e o grupo não tórica com 64 olhos. No pré-operatório foram avaliados dados topográficos do olho a ser operado e refração. No período pós-operatório foram revisados dados da refração e acuidades visuais com e sem correção. RESULTADOS: O astigmatismo corneano pré-operatório variou de 1,00 a 5,6 DC em ambos os grupos, sendo que no grupo tórica houve redução média de 1,37 DC (p<0,001), quando comparado ao refracional. O grupo não tórica apresentou redução média de 0,16 DC (p=0,057). Com relação a acuidade visual sem correção (AVSC), o grupo tórica apresentou 44 olhos (51,7%) com AVSC de 0 logMAR (20/20) ou 0,1 logMAR (20/25), e o grupo não tórica apenas 7 olhos (10,93%) com estas mesmas AVSC. DISCUSSÃO: Ficou bem evidenciado que os pacientes com astigmatismo ceratométrico significativo apresentam benefício visual com o implante de LIO tórica. A diminuição do uso de auxílios ópticos para distância pode ser possível a partir do momento que conseguimos corrigir com melhor precisão as aberrações do olho humano. Na atualidade, a facoemulsificação passou a ser além de uma cirurgia para restabelecimento funcional, um procedimento refracional.


PURPOSES: Compare the visual acuity of patients who underwent cataract surgery by phacoemulsification with IOL AcrySof® toric implantation versus AcrySof® IQ and evaluate the reduction of cylindrical diopters (CD) in the postoperative period. METHODS: Analytical and retrospective study of 149 eyes with 1 or more diopters of regular symmetrical keratometric astigmatism, which underwent cataract surgery by phacoemulsification. The eyes were divided into two groups: the toric group with 85 eyes and the non-toric group with 64 eyes. In the pre-operative phase, topographic data and refraction of each eye to be operated were assessed. In the postoperative phase, refraction and visual acuity with and without correction were measured. RESULTS: The preoperative topographic astigmatism ranged from 1.00 to 5.6 DC in both groups. Average reduction of 1.37 CD (p<0.001) and 0.16 CD (p=0.057) was obtained for the toric and non-toric group when compared to the refractive astigmatism, respectively. Considering visual acuity without correction (NCVA), the toric group presented 44 eyes (51.7%) with NCVA of 0 logMAR (20/20) or 0.1 logMAR (20/25) and the toric group presented 7 eyes (10.93%) with these same NCVA values. DISCUSSION: The results show that patients with a significant keratometric astigmatism presented visual benefits with the toric IOL implantation. The reduction of the use of optical aids may be obtained provided aberrations of the human eye are corrected more accurately. Currently, phacoemulsification surgery has been used not only for functional improvement, but also as a refraction procedure.


Assuntos
Idoso , Feminino , Humanos , Masculino , Astigmatismo/cirurgia , Lentes Intraoculares , Implante de Lente Intraocular/métodos , Facoemulsificação/métodos , Acuidade Visual/fisiologia , Astigmatismo/fisiopatologia , Período Pós-Operatório , Desenho de Prótese , Valores de Referência , Estudos Retrospectivos , Refração Ocular/fisiologia , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA