1.
Arq. bras. oftalmol ; 82(3): 195-199, May-June 2019. tab
Artigo em Inglês | LILACS | ID: biblio-1001305

RESUMO

ABSTRACT Purpose: To investigate changes in axial length after intravitreal dexamethasone implantation in patients with macular edema. Methods: We performed a prospective comparative study of 46 patients with unilateral macular edema, due to diabetic retinopathy, retinal vein occlusion, and non-infectious uveitis, who underwent dexamethasone implantation. The fellow eyes of the patients were considered the control group. The central macular thickness was measured by spectral-domain optical coherence tomography, and axial length was measured by IOLMaster 700 optical coherence biometry. We compared axial length and central macular thickness values within the groups. Results: In the study group, the baseline central macular thickness was 460.19 ± 128.64 mm, significantly decreasing to 324.00 ± 79.84 mm after dexamethasone implantation (p=0.000). No significant change in central macular thickness measurements was seen in the control group (p=0.244). In the study group, the baseline axial length was 23.16 ± 0.68 mm, significantly increasing to 23.22 ± 0.65 mm after dexamethasone implantation (p=0.039). However, the control group exhibited no significant change in axial length (p=0.123). Conclusions: In addition to significantly reducing central macular thickness measurements, intravitreal dexamethasone implantation also significantly changes optical biometry-based axial length measurements.


RESUMO Objetivo: Investigar alterações no comprimento axial após implante de dexametasona intravítrea em pacientes com edema macular. Métodos: Foi realizado um estudo prospectivo e comparativo de 46 pacientes com edema macular unilateral, devido à retinopatia diabética, oclusão da veia retiniana e uveíte não infecciosa, que foram submetidos ao implante de dexametasona. Os olhos contralateral de cada paciente foram considerados o grupo controle. A espessura macular central foi medida por tomografia de coerência óptica de domínio espectral, e o comprimento axial foi medido por meio de biometria de coerência óptica de domínio espectral e o comprimento axial foi medido pela biometria de coerência óptica com IOLMaster 700. Comparamos o comprimento axial e os valores da espessura macular central dentro dos grupos. Resultados: No grupo de estudo, a espessura macular basal foi de 460,19 ± 128,64 mm, diminuindo significativamente para 324,00 ± 79,84 mm após o implante de dexametasona (p=0,000). Nenhuma mudança significativa nas medidas da espessura macular central foi observada no grupo controle (p=0,244). No grupo de estudo, o comprimento axial basal foi de 23,16 ± 0,68 mm, aumentando significativamente para 23,22 ± 0,65 mm após o implante de dexametasona (p=0,039). No entanto, o grupo controle não apresentou alteração significativa no comprimento axial (p=0,123). Conclusões: Além de reduzir significativamente as medidas da espessura macular central, o implante de dexametasona intravítrea também altera significativamente as medidas de comprimento axial baseadas na biometria óptica.


Assuntos
Humanos , Masculino , Feminino , Adulto , Pessoa de Meia-Idade , Idoso , Idoso de 80 Anos ou mais , Dexametasona/administração & dosagem , Edema Macular/tratamento farmacológico , Comprimento Axial do Olho/efeitos dos fármacos , Injeções Intravítreas/métodos , Glucocorticoides/administração & dosagem , Macula Lutea/efeitos dos fármacos , Acuidade Visual , Edema Macular/patologia , Estudos Prospectivos , Biometria/métodos , Resultado do Tratamento , Estatísticas não Paramétricas , Tomografia de Coerência Óptica/métodos , Retinopatia Diabética/tratamento farmacológico , Comprimento Axial do Olho/patologia , Macula Lutea/patologia
2.
Rev. bras. oftalmol ; 77(5): 272-277, set.-out. 2018. tab, graf
Artigo em Inglês | LILACS | ID: biblio-977871

RESUMO

Abstract Purpose: To report the prevalence and analyse corneal astigmatism patterns in cataract surgery candidates. Methods: Researchers examined 2136 eyes from 1204 patients for cataract surgery from 1 January to 31 December 2016. All the candidates were evaluated with partial coherence interferometry (IOLMaster). The results were analysed statistically in relation to qualitative and quantitative variables. Results: The mean age of the patients was 71.9 years with a female predominance. Mean corneal astigmatism was 1.0 dioptre (D). Against the rule (ATR) astigmatism increased with age. Women presented with steeper corneas than men. In those patients who had both eyes measured, we found strong correlations between amount of right and left eye astigmatism, axis and keratometry. Overall, 39% of the eyes had corneal astigmatism > 1.00 D and 19% >1.50 D. Conclusions: A significant percentage of our population presents with corneal astigmatism > 1.00 D with a shift from WTR (with the rule) to ATR with increasing age. Our findings, in a population that has never been described before, will be helpful to surgeons to enhance surgical techniques, patients to improve visual outcomes, IOL (intraocular lens) manufacturers to make better designs and health agents to optimise resources.


Resumo Objetivo: Relatar a prevalência e analisar os padrões de astigmatismo corneano em candidatos à cirurgia de catarata. Métodos: Os pesquisadores examinaram 2136 olhos de 1204 pacientes a cirurgia de catarata de 1 de janeiro a 31 de dezembro de 2016. Todos os candidatos foram avaliados com interferometria de coerência parcial (IOLMaster). Os resultados foram analisados estatisticamente em relação às variáveis qualitativa e quantitativa. Resultados: A média de idade dos pacientes foi de 71,9 anos, com predomínio do sexo feminino. A média de astigmatismo corneano foi de 1,0 dioptria (D). Contra a regra (ATR), o astigmatismo aumentou com a idade. As mulheres apresentaram córneas mais íngremes que os homens. Nos pacientes que tiveram os dois olhos medidos, encontramos fortes correlações entre quantidade de astigmatismo nos olhos direito e esquerdo, eixo e ceratometria. No geral, 39% dos olhos tinham astigmatismo corneano >1,00 D, e 19% > 1,50 D. Conclusões: Uma percentagem significativa da nossa população apresenta astigmatismo corneano >1,00, D com uma mudança de WTR (a favor da regra) para ATR (contra a regra) com o aumento da idade. Nossas descobertas em uma população que nunca foi descrita antes serão úteis para os cirurgiões melhorarem suas técnicas cirúrgicas, os pacientes melhorarem seus resultados visuais, os fabricantes de LIOs (lentes intraoculares) criarem projetos melhores, e os agentes de saúde otimizarem os recursos.


Assuntos
Humanos , Masculino , Feminino , Adulto , Pessoa de Meia-Idade , Idoso , Idoso de 80 Anos ou mais , Astigmatismo/epidemiologia , Facoemulsificação/estatística & dados numéricos , Córnea/diagnóstico por imagem , Interferometria , Astigmatismo/fisiopatologia , Extração de Catarata/estatística & dados numéricos , Prevalência , Biometria/instrumentação , Comprimento Axial do Olho , Imagem Óptica/instrumentação , Câmara Anterior
3.
Rev. bras. oftalmol ; 77(4): 184-188, jul.-ago. 2018. tab, graf
Artigo em Inglês | LILACS | ID: biblio-959100

RESUMO

ABSTRACT Objective: To evaluate the correlation of optical biometry and target with variable ages, anterior chamber depth, axial length, R1/K1 and R2/K2 established by two optical biometry devices in patients with cataract. Methods: The study included the analysis of 348 medical records, from which 503 cataract eyes were selected, which underwent evaluation by the optical biometric devices IOL Master 700 and Lenstar LS 900 in the period of April to July 2017. Data collected were: age, anterior chamber depth, axial length, R1/K1 and R2/K2. Results: The average of the biometrics obtained using Lenstar was 21.02, varying 3.46, more or less, with an average target of -0.02, varying 0.45. In relation to the IOL Master it was 21.19, with a variation of 3.40 and average target of -0.01, a variation of 0.11. It can be observed that despite close values in relation to the mean, there was significance (p<0.001). Axial length (p<0.001) and R1/K1 (p<0.001) had an influence on the difference of the biometric values between the devices. Conclusion: A high degree of clinical and statistical correspondence was observed between the results obtained by the biometry devices in patients with cataract.


RESUMO Objetivos: Avaliar a correlação da biometria óptica e target com as variáveis idade, profundidade da câmara anterior, comprimento axial, R1/K1 e R2/K2 estabelecidos por dois dispositivos de biometria óptica em pacientes com catarata. Métodos: O trabalho abrangeu a análise de 348 prontuários dos quais foram selecionados 503 olhos com catarata ,que passaram pela avaliação nos dispositivos de biometria óptica IOL Master 700 e Lenstar LS 900 no período de abril a julho de 2017. Os dados colhidos foram: idade, profundidade da câmara anterior, comprimento axial, R1/K1 e R2/K2 . Resultados: A média da biometria obtida utilizando o Lenstar foi de 21,02, variando 3,46 para mais ou para menos, com target médio de -0,02, variando 0,45. Já em relação ao IOL Master foi de 21,19, com variação de 3,40 e target médio de -0,01, variação de 0,11. Pode-se observar que apesar de valores próximos em relação à média, houve significância (p < 0,001). Houve a concordância da biometria em relação ao comprimento axial (p < 0,001) e R1/K1(p < 0,001). Conclusão: Observou-se alto grau de correspondência clínica e estatística entre os resultados obtidos pelos dispositivos de biometria em pacientes com catarata.


Assuntos
Humanos , Masculino , Feminino , Adulto , Pessoa de Meia-Idade , Idoso , Idoso de 80 Anos ou mais , Erros de Refração/diagnóstico por imagem , Catarata/diagnóstico , Biometria/instrumentação , Biometria/métodos , Comprimento Axial do Olho/diagnóstico por imagem , Lentes Intraoculares/normas , Câmara Anterior/diagnóstico por imagem , Refração Ocular/fisiologia , Extração de Catarata/métodos , Acuidade Visual , Estudos Transversais , Reprodutibilidade dos Testes , Córnea/diagnóstico por imagem , Topografia da Córnea/instrumentação , Implante de Lente Intraocular/métodos , Período Pré-Operatório , Registros Eletrônicos de Saúde , Estudo Observacional , Cristalino/diagnóstico por imagem
4.
Rev. bras. oftalmol ; 74(6): 350-354, nov.-dez. 2015. tab, graf
Artigo em Inglês | LILACS | ID: lil-767072

RESUMO

RESUMO Objetivo: Avaliar os parâmetros biométricos oculares por meio da biometria óptica e observar uma possível diferença refratométrica esférica, assim como sua variação, baseada no cálculo pré-cirúrgico estimado e na refração esférica pós-cirurgia de catarata pela facoemulsificação com implante de lente intraocular (LIO). Métodos: Foram revisados 252 prontuários eletrônicos entre 2013 e 2014 dos quais foram selecionados 117 pacientes adultos (189 olhos) submetidos à facoemulsificação com implante de LIO dobrável pelo mesmo cirurgião e examinados através do IOLMaster® 500. O poder dióptrico da LIO foi calculado pela fórmula de Haigis. O teste de Wilcoxon foi empregado para testar a existência de diferença significativa (p<0,05) entre o grau esférico esperado (GEE) e o grau esférico final (GEF). Resultados: Foram operados 98 olhos direitos (OD) e 91 esquerdos (OE). Após calculada a variação entre o GEE e o GEF observou-se que 55% dos OD alcançaram resultados dentro de ± 0,5 dioptrias (D) e 89% resultados dentro de ± 1D. Quanto ao OE, 46% alcançaram resultados dentro de ± 0,5D e 78% dentro de ± 1D. Conclusão: A biometria óptica pode ser utilizada como um método confiável, previsível e reprodutível para que seja estimado o GEF de ambos olhos.


ABSTRACT Objective: To assess ocular biometric parameters by optical biometry and to observe a possible spherical refractive difference, as well as its variation based on estimated preoperative calculation and the spherical refraction post cataract surgery by phacoemulsification with intraocular lens implant (IOL). Methods: After reviewing 252 electronic medical records between 2013 and 2014, 117 adult patients (189 eyes) were selected.The patients underwent phacoemulsification with foldable IOL implantation by the same surgeon and were examined by IOLMaster® 500.The IOL power was calculated using the Haigis formula.The Wilcoxon test was applied to identify the existence of significant differences (p<0.05) between the spherical expected refraction (SER) and the final spherical refraction (FSR) of the eyes. Results: There were operated 98 right eyes (OD) and 91 left (OS). A calculation of the variation between FSR and SER indicated that 55% of the OD reached results within ± 0.5 diopters (D) and 89% within ± 1D. With respect to OS, 46% achieved results within ± 0.5D and 78% within ± 1D. Conclusion: Optical biometry is a reliable, predictable and reproducible method to estimate the FSR of both eyes.


Assuntos
Humanos , Masculino , Feminino , Adulto , Pessoa de Meia-Idade , Idoso , Idoso de 80 Anos ou mais , Biometria/instrumentação , Biometria/métodos , Facoemulsificação/métodos , Implante de Lente Intraocular/métodos , Comprimento Axial do Olho/anatomia & histologia , Refração Ocular/fisiologia , Extração de Catarata/métodos , Estudos Transversais , Valor Preditivo dos Testes , Reprodutibilidade dos Testes , Registros Eletrônicos de Saúde , Lentes Intraoculares
5.
Arq. bras. oftalmol ; 78(5): 286-289, Sep.-Oct. 2015. tab, ilus
Artigo em Inglês | LILACS | ID: lil-761526

RESUMO

ABSTRACTPurpose:To evaluate the outcomes and complications following phacoemulsification surgery in eyes with cataract and high myopia.Methods:We retrospectively evaluated the data of 43 eyes of 28 consecutive patients (12 males, 16 females) with cataract and high myopia who had undergone phacoemulsification and intraocular lens (IOL) implantation. The mean [± standard deviation (range)] age of the patients was 59.20 ± 11.08 (39-77) years.Results:The frequency of nuclear cataract was significantly higher than that of other cataract types (P=0.003). The mean axial length was 28.97 ± 1.99 (26-33) mm and the mean IOL power was 5.09 ± 4.78 (-3.0 to +14.0) diopters (D). The mean preoperative spherical equivalent (SE) was -16.48 ± 5.23 (-8.00 to -25.00) D and the mean postoperative SE was -1.46 ± 0.93 (0.00 to -3.00) D (P=0.00). The mean preoperative best-corrected visual acuity (BCVA) was 0.91 ± 0.37 (0.30 to -1.50) logMAR and the mean postoperative BCVA was 0.29 ± 0.25 (0.00-1.00) logMAR (P=0.00). Twenty-two eyes (51.2%) achieved the target postoperative refraction (±1.0 D). The eyes were divided into 3 groups according to the axial length. The mean biometric error was significantly higher in the group with the greatest axial length than in the other groups (P=0.007). Preoperative argon laser photocoagulation was performed in 7 eyes (16%) on account of retinal tears, retinal holes, or lattice degeneration. Postoperatively, retinal tears developed in 2 eyes (4%) and were treated with photocoagulation. One eye (2%) developed retinal detachment postoperatively, with the patient consequently referred for retinal surgery. Postoperatively, posterior capsule opacities developed in 11 eyes (25%), with all cases treated by laser capsulotomy.Conclusions:Good postoperative outcomes following phacoemulsification surgery were observed in patients with cataract and high myopia. However, clinicians should be aware of the risk of postoperative retinal tears and rhegmatogenous retinal detachment. Preoperative prophylactic argon laser photocoagulation treatment should be considered where necessary.


RESUMOObjetivo:Avaliação dos resultados e complicações associadas à cirurgia de facoemulsificação em olhos com catarata e miopia alta.Método:Quarenta e três olhos de 28 pacientes (12 homens, 16 mulheres) consecutivos com catarata e alta miopia, que haviam sido submetidos a facoemulsificação e implante de lentes intraoculares (LIO), foram avaliados retrospectivamente. A idade foi de 59,20 ± 11,08, (39-77) anos [média ± desvio padrão, (variação)].Resultados:A frequência de catarata nuclear foi significativamente maior do que os outros tipos (p=0,003). O comprimento axial foi 28,97 ± 1,99, (26-33) mm e o poder da LIO foi 5,09 ± 4,78, (-3,0 a 14,0) dioptrias (D). O equivalente esférico pré-operatório (SE) foi de -16,48 ± 5,23, (-25,00 a -8,00) D e o SE pós-operatório foi -1,46 ± 0,93, (0,00 a -3,00) D, (P=0,00). A melhor acuidade visual corrigida pré-operatória (BCVA) foi de 0,91 ± 0,37, (0,30 -1,50) logMAR e a BCVA pós-operatória foi de 0,29 ± 0,25, (0,00-1,00) logMAR, (P=0,00). Vinte e dois olhos (51,2%) estavam dentro de refração alvo pós-operatória (± 1,0 D). Os olhos foram divididos em três grupos, de acordo com o comprimento axial. O erro biométrico foi significativamente maior no terceiro grupo, em comparação com os outros grupos (p=0,007). Fotocoagulação pré-operatória por laser de argônio foi realizada em 7 olhos (16%) devido a roturas retinianas, buracos de retina ou degeneração látice. No pós-operatório, as roturas da retina ocorreram em dois olhos (4%); tratados com fotocoagulação. Um olho (2%) desenvolveu descolamento de retina no pós-operatório e foi encaminhado para cirurgia de retina. No pós-operatório, opacidades da cápsula posterior ocorreram em 11 olhos (25%) e estes foram tratados com capsulotomia a laser.Conclusões:A cirurgia de facoemulsificação permite bons resultados em pacientes com catarata e miopia alta. No entanto, devemos estar atentos para a possibilidade de roturas da retina pós-operatórias e para o descolamento de retina regmatogênico. Se necessário, devemos usar o tratamento profilático de fotocoagulação a laser antes da cirurgia.


Assuntos
Adulto , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Implante de Lente Intraocular/efeitos adversos , Miopia/cirurgia , Facoemulsificação/efeitos adversos , Comprimento Axial do Olho/fisiopatologia , Fotocoagulação a Laser/métodos , Lasers de Gás/uso terapêutico , Implante de Lente Intraocular/métodos , Período Pós-Operatório , Período Pré-Operatório , Facoemulsificação/métodos , Complicações Pós-Operatórias/prevenção & controle , Procedimentos Cirúrgicos Profiláticos/métodos , Estudos Retrospectivos , Descolamento Retiniano/etiologia , Descolamento Retiniano/prevenção & controle , Perfurações Retinianas/etiologia , Perfurações Retinianas/prevenção & controle , Estatísticas não Paramétricas , Resultado do Tratamento , Acuidade Visual
6.
Arq. bras. oftalmol ; 78(3): 180-184, May-Jun/2015. tab
Artigo em Inglês | LILACS | ID: lil-753016

RESUMO

ABSTRACT Purpose: To evaluate the difference in terms of refractive errors and anterior segment parameters between schizophrenic patients and healthy volunteers. Methods: This study compared 70 patients (48 men) who were diagnosed with schizophrenia with a control group of 60 (35 men) who were similar in terms of age, gender, education, and socioeconomic level. Anterior segment examination was performed using a Scheimflug system. Axial length and lens thickness (LT) were measured using optic biometry. The following tests were administered to the psychiatric patient group: Brief Psychiatric Rating Scale (BPRS), Scale for the Assessment of Negative Symptoms (SANS), and Scale for the Assessment of Positive Symptoms (SAPS). Results: Mild myopia was detected in both the schizophrenic and control groups, with no statistically significant difference (p>0.005). Corneal volume (CV), anterior chamber volume (ACV), anterior chamber depth (ACD), and central corneal thickness (CCT) values were lower in the schizophrenic group, and there was a statistically significant between-group difference (p=0.026, p=0.014, p=0.048, and p=0.005, respectively). LT was greater in schizophrenics, and the difference was found to be statistically significant (p=0.006). A statistically significant negative correlation was found between SAPS and cylinder values (p=0.008). The axial eye length, cylinder value, pupil diameter, mean keratometric value, and anterior chamber angle revealed no statistically significant difference between the groups (p>0.05). Conclusion: No statistically significant difference was detected in terms of refraction disorders between schizophrenics and the healthy control group, while some differences in anterior chamber parameters were present. These results demonstrate that schizophrenics may exhibit clinical and structural differences in the eye. .


RESUMO Objetivo: Avaliar se existem diferenças em relação aos erros refracionais e parâmetros do segmento anterior entre pacientes com esquizofrenia e voluntários saudáveis. Métodos: Este estudo comparou 70 pacientes diagnosticados com esquizofrenia (48 homens) com um grupo controle de 60 pacientes, semelhantes em relação à idade, sexo, escolaridade e nível socioeconômico (35 homens). O exame do segmento anterior foi realizado com o sistema Scheimflug; os comprimentos axiais do olho e a espessura do cristalino foram avaliadas por meio de biometria óptica. Os seguintes testes foram aplicados ao grupo de pacientes psiquiátricos: Brief Psychiatric Rating Scale (BPRS), Scale for the Assessment of Negative Symptoms (SANS), e Scale for the Assessment of Positive Symptoms (SAPS). Resultados: Miopia leve foi detectada em ambos os grupos de esquizofrenia e de controle, sem diferença estatisticamente significativa (p>0,005). Volume de córnea (CV), volume da câmara anterior (ACV), profundidade da câmara anterior (ACD) e paquimetria central da córnea (CCT) apresentaram valores menores no grupo de esquizofrênicos e houve diferença estatisticamente significativa entre os dois grupos (p=0,026, p=0,014, p=0,048 e p=0,005, respectivamente). A espessura do cristalino (LT) foi maior em esquizofrênicos e a diferença foi estatisticamente significativa (p=0,006). Foi encontrada uma correlação negativa estatisticamente significativa entre SAPS e os valores cilíndricos (p=0,008). O comprimento axial do olho, o valor do cilindro, o diâmetro pupilar, a ceratometria média e o ângulo da câmara anterior não revelaram nenhuma diferença estatística entre os grupos (p>0,05). Conclusões: Não foi detectada diferença estatisticamente significativa em relação aos transtornos de refração entre os esquizofrênicos e o grupo controle, enquanto algumas diferenças nos parâmetros de câmara anterior estavam presentes. Estes resultados demonstram que esquizofrénicos podem ...


Assuntos
Adulto , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Adulto Jovem , Segmento Anterior do Olho , Biometria/métodos , Erros de Refração , Esquizofrenia , Segmento Anterior do Olho/fisiopatologia , Comprimento Axial do Olho/patologia , Estudos Transversais , Córnea/anatomia & histologia , Cristalino/patologia , Miopia/complicações , Miopia/diagnóstico , Escalas de Graduação Psiquiátrica , Pupila/fisiologia , Erros de Refração/diagnóstico , Erros de Refração/fisiopatologia , Fatores Socioeconômicos , Inquéritos e Questionários , Esquizofrenia/tratamento farmacológico , Esquizofrenia/fisiopatologia , Fatores de Tempo
7.
Rev. bras. oftalmol ; 73(6): 348-350, Nov-Dec/2014. tab, graf
Artigo em Inglês | LILACS | ID: lil-741915

RESUMO

Purpose: To correlate clinical findings of Vogt-Koyanagi-Harada disease with standardized echography findings in a cross-sectional, descriptive and observational study. Methods: Patients with Vogt-Koyanagi-Harada disease in the convalescent and recurrence phases were evaluated with standardized ocular echography. Eyes with opaque media were excluded. Clinical findings were correlated with echographic data. Results: Thirty-seven eyes of 25 patients were included. Best corrected visual acuity was in average 20/100 (0.70 logMAR). Clinical findings included: sunset glow fundus (92%), pigment migration (92%), nummular chorioretinal depigmented scars (68%) and subretinal fibrosis (64.8%). Standardized echography was able to recognize all the cases with subretinal fibrosis (n=24) described clinically. Standardized echography showed a 100% sensitivity and specificity of finding subretinal fibrosis. Subretinal fibrosis in patients with Vogt-Koyanagi-Harada represents a risk factor for low vision. In our patients’ eyes, presence of subretinal fibrosis had a 2.5 time relative risk of having a visual acuity equal or worst to 20/70. Conclusions: Standardized echography represents a useful tool in patients with VKH in the chronic (convalescence and recurrence) phase of the disease. Subretinal fibrosis, a sight threatening complication in the convalescence and recurrent phases of Vogt-Koyanagi-Harada, can be diagnosed with ocular echography, with characteristic images. Knowledge of these images can be useful in cases with opaque media and bilateral anterior segment granulomatous inflammatory disease. .


Objetivo: Correlacionar achados clínicos da síndrome de Vogt-Koyanagi-Harada com resultados ecográficos padronizado da doença em um estudo transversal, descritivo e observacional. Métodos: Pacientes com a doença de Vogt-Koyanagi-Harada, o convalescente e recorrência em fases padronizadas foram avaliados com ecografia ocular. Olhos com material opaco foram excluídos. Achados clínicos foram correlacionados com dados ecográficos. Resultados: Um total de 25 pacientes e trinta e sete olhos foram incluídos no estudo. A acuidade visual (AV) 20/100 foi em média 0.70 logMAR. Os achados clínicos incluídos: sunset glow fundus (92%), pigmento migração (92%), numular despigmentado cicatrizes coriorretinianas (68%) e fibrose sub-retiniana (64,8%). A ecografia padronizada foi capaz de reconhecer todos os casos de fibrose sub-retiniana (n= 24) descrito clinicamente. A ecografia revelou um padrão 100% de sensibilidade e especificidade do diagnóstico fibrose sub-retiniana. Sub-retiniana em pacientes com fibrose Vogt-Koyanagi-Harada representa um fator de risco para a baixa visão. Em nossos pacientes olhos, presença de fibrose subretiniana tinham um risco relativo 2,5 hora de ter uma acuidade visual igual ou pior para 20/70. Conclusão: Ecografia padronizadarepresenta uma ferramenta útil em pacientes portadores da doença na fase crônica (convalescença, e recidiva). Fibrose sub-retiniana, uma visão ameaçadora e complicação na convalescença e recorrentes nas fases da Síndrome de Vogt-Koyanagi- Harada, podem ser diagnosticados com ecografia ocular, com imagens características. O conhecimento dessas imagens pode ser útil em casos com material opaco e segmento anterior bilateral da doença inflamatória granulomatosa. .


Assuntos
Humanos , Masculino , Feminino , Criança , Adolescente , Adulto , Pessoa de Meia-Idade , Síndrome Uveomeningoencefálica/complicações , Síndrome Uveomeningoencefálica/patologia , Síndrome Uveomeningoencefálica/diagnóstico por imagem , Ultrassonografia/normas , Técnicas de Diagnóstico Oftalmológico/normas , Retina/diagnóstico por imagem , Doenças Retinianas/etiologia , Doenças Retinianas/diagnóstico por imagem , Uveíte/etiologia , Uveíte/diagnóstico por imagem , Fibrose , Acuidade Visual , Doença Crônica , Estudos Transversais , Corioide/diagnóstico por imagem , Comprimento Axial do Olho , Estudo Observacional , Fundo de Olho , México