1.
Arq. bras. oftalmol ; 83(2): 141-145, Mar.-Apr. 2020. tab, graf
Artigo em Inglês | LILACS | ID: biblio-1088976

RESUMO

ABSTRACT Purpose: To compare the postoperative refractive predictability of IOLMaster 500 and Pentacam HR on the basis of keratometry and anterior chamber depth values in eyes with an indication for multifocal intraocular lens (IOL) implantation. Methods: This was a retrospective study conducted on 118 eyes treated with phacoemulsification and multifocal intraocular lens implantation. Only the eyes that achieved emmetropia in the dynamic refraction performed on postoperative day 30 were included. Haigis' formula was used in each case to calculate the intraocular lens power, and the intraocular lens with the target refraction closest to emmetropia was implanted. Four lens calculation scenarios were tested by combining keratometry and anterior chamber depth measurements obtained using the two devices. Results: IOLMaster 500 and Pentacam HR differed with regard to mean keratometry (D 0.07 ± 0.03 D; p=0.0065) and anterior chamber depth (D 0.08 ± 0.01 mm; p<0.001). In the analysis of covariance, the following differences were obtained using the Haigis' formula when confronted with the biometric values obtained by inserting keratometry and anterior chamber depth values, respectively: Penta/IOL x IOL/Penta (0.13 ± 0.03; p<0.0001); Penta/Penta × IOL/Penta (0.13 ± 0.03; p<0.0001); Penta/IOL × IOL/IOL (0.11 ± 0.03; p=0.001); Penta/Penta × IOL/IOL (0.11 ± 0.03; p=0.002); IOL/IOL × IOL/Penta (0.02 ± 0.03; p=0.865); and Penta/IOL × Penta/Penta (0.002 ± 0.03; p=0.99). The difference was smaller when measuring the anterior chamber depth using the IOLMaster 500, regardless of which device was used to measure keratometry. Conclusions: Pentacam HR significantly differed from IOLMaster 500 when calculating keratometry. As regards the anterior chamber depth, the two devices were equally accurate.


RESUMO Objetivo: Comparar a previsibilidade refrativa pós-operatória do IOLMaster 500 e Pentacam HR com base nos valores de ceratometria e profundidade de câmara anterior nos olhos com indicação de implante de lentes intraoculares multifocais. Métodos: Estudo retrospectivo realizado em 118 olhos tratados com facoemulsificação e implante de lentes intraoculares multifocal. Apenas os olhos que atingiram a emetropia na refração dinâmica no 30º dia pós-operatório foram incluídos. A fórmula de Haigis foi usada em cada caso para calcular o poder das lentes intraoculares, e a lente intraocular com a refração alvo mais próxima da emetropia foi implantada. Cenários de cálculo de quatro lentes foram testados pela combinação de medidas de ceratometria e profundidade de câmara anterior obtidas usando os dois dispositivos. Resultados: IOLMaster 500 e Pentacam HR diferiram quanto à média de ceratometria (D 0,07 ± 0,03 D; p=0,0065) e profundidade de câmara anterior (D 0,08 ± 0,01 mm; p<0,001). Na análise da covariância, as seguintes diferenças foram obtidas usando a fórmula de Haigis quando confrontadas com os valores biométricos obtidos pela inserção dos valores de ceratometria e profundidade de câmara anterior, respectivamente: Penta/IOL x IOL/Penta (0,13 ± 0,03; p<0,0001); Penta/Penta x IOL/Penta (0,13 ± 0,03; p<0,0001); Penta/IOL x IOL/IOL (0,11 ± 0,03; p=0,001); Penta/Penta x IOL/IOL (0,11 ± 0,03; p=0,002); IOL/IOL x IOL/Penta (0,02 ± 0,03; p=0,865); Penta/IOL x Penta/Penta (0,002 ± 0,03; p=0,99). A diferença foi menor ao medir a profundidade da câmara anterior usando o IOLMaster 500, independentemente de qual dispositivo foi usado para medir a ceratometria. Conclusões: O Pentacam HR diferiu significativamente do IOLMaster 500 no cálculo de ceratometria. Quanto à profundidade da câmara anterior, os dois dispositivos foram igualmente precisos.


Assuntos
Humanos , Masculino , Feminino , Pessoa de Meia-Idade , Idoso , Facoemulsificação/métodos , Córnea/patologia , Topografia da Córnea/instrumentação , Implante de Lente Intraocular/métodos , Lentes Intraoculares Multifocais , Câmara Anterior/patologia , Período Pós-Operatório , Valores de Referência , Refração Ocular/fisiologia , Fatores de Tempo , Acuidade Visual/fisiologia , Valor Preditivo dos Testes , Estudos Retrospectivos , Biometria , Resultado do Tratamento , Córnea/diagnóstico por imagem , Interferometria/instrumentação , Interferometria/métodos , Câmara Anterior/diagnóstico por imagem
2.
Rev. bras. oftalmol ; 77(5): 272-277, set.-out. 2018. tab, graf
Artigo em Inglês | LILACS | ID: biblio-977871

RESUMO

Abstract Purpose: To report the prevalence and analyse corneal astigmatism patterns in cataract surgery candidates. Methods: Researchers examined 2136 eyes from 1204 patients for cataract surgery from 1 January to 31 December 2016. All the candidates were evaluated with partial coherence interferometry (IOLMaster). The results were analysed statistically in relation to qualitative and quantitative variables. Results: The mean age of the patients was 71.9 years with a female predominance. Mean corneal astigmatism was 1.0 dioptre (D). Against the rule (ATR) astigmatism increased with age. Women presented with steeper corneas than men. In those patients who had both eyes measured, we found strong correlations between amount of right and left eye astigmatism, axis and keratometry. Overall, 39% of the eyes had corneal astigmatism > 1.00 D and 19% >1.50 D. Conclusions: A significant percentage of our population presents with corneal astigmatism > 1.00 D with a shift from WTR (with the rule) to ATR with increasing age. Our findings, in a population that has never been described before, will be helpful to surgeons to enhance surgical techniques, patients to improve visual outcomes, IOL (intraocular lens) manufacturers to make better designs and health agents to optimise resources.


Resumo Objetivo: Relatar a prevalência e analisar os padrões de astigmatismo corneano em candidatos à cirurgia de catarata. Métodos: Os pesquisadores examinaram 2136 olhos de 1204 pacientes a cirurgia de catarata de 1 de janeiro a 31 de dezembro de 2016. Todos os candidatos foram avaliados com interferometria de coerência parcial (IOLMaster). Os resultados foram analisados estatisticamente em relação às variáveis qualitativa e quantitativa. Resultados: A média de idade dos pacientes foi de 71,9 anos, com predomínio do sexo feminino. A média de astigmatismo corneano foi de 1,0 dioptria (D). Contra a regra (ATR), o astigmatismo aumentou com a idade. As mulheres apresentaram córneas mais íngremes que os homens. Nos pacientes que tiveram os dois olhos medidos, encontramos fortes correlações entre quantidade de astigmatismo nos olhos direito e esquerdo, eixo e ceratometria. No geral, 39% dos olhos tinham astigmatismo corneano >1,00 D, e 19% > 1,50 D. Conclusões: Uma percentagem significativa da nossa população apresenta astigmatismo corneano >1,00, D com uma mudança de WTR (a favor da regra) para ATR (contra a regra) com o aumento da idade. Nossas descobertas em uma população que nunca foi descrita antes serão úteis para os cirurgiões melhorarem suas técnicas cirúrgicas, os pacientes melhorarem seus resultados visuais, os fabricantes de LIOs (lentes intraoculares) criarem projetos melhores, e os agentes de saúde otimizarem os recursos.


Assuntos
Humanos , Masculino , Feminino , Adulto , Pessoa de Meia-Idade , Idoso , Idoso de 80 Anos ou mais , Astigmatismo/epidemiologia , Facoemulsificação/estatística & dados numéricos , Córnea/diagnóstico por imagem , Interferometria , Astigmatismo/fisiopatologia , Extração de Catarata/estatística & dados numéricos , Prevalência , Biometria/instrumentação , Comprimento Axial do Olho , Imagem Óptica/instrumentação , Câmara Anterior