Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
1.
Rev. Assoc. Med. Bras. (1992) ; 66(12): 1750-1756, Dec. 2020. graf
Artigo em Inglês | Sec. Est. Saúde SP, LILACS | ID: biblio-1143664

RESUMO

SUMMARY Cardiovascular diseases are important causes of morbidity and mortality in the course of chronic kidney disease (CKD). Diastolic dysfunction (DD) may progress with the clinical manifestation of heart failure, known as heart failure with preserved ejection fraction, a condition that precedes systolic dysfunction. The early identification of DD by echocardiography at the point-of-care before the appearance of symptoms and signs of pulmonary congestion and the implementation of appropriate treatment can improve the prognosis of CKD. This review article briefly addresses DD in kidney disease and presents a practical approach to the echocardiographic diagnosis of DD at the point of care.


SUMÁRIO As doenças cardiovasculares são causa importante de morbidade e mortalidade no curso da doença renal crônica (DRC). A disfunção diastólica (DD) pode evoluir com insuficiência cardíaca manifesta clinicamente, denominada insuficiência cardíaca com fração de ejeção preservada, e precede a disfunção sistólica. A identificação precoce da DD pela ecocardiografia "point of care", antes do aparecimento dos sintomas e sinais de congestão pulmonar, e a implementação de tratamento adequado podem melhorar o prognóstico da DRC. Este artigo de revisão aborda brevemente a DD na doença renal e apresenta uma abordagem prática para o diagnóstico ecocardiográfico da DD à beira do leito


Assuntos
Humanos , Disfunção Ventricular Esquerda/diagnóstico por imagem , Insuficiência Cardíaca/terapia , Insuficiência Cardíaca/diagnóstico por imagem , Volume Sistólico , Sistemas Automatizados de Assistência Junto ao Leito , Diástole , Nefrologistas
2.
Ciênc. Saúde Colet. (Impr.) ; 24(11): 4297-4305, nov. 2019. tab, graf
Artigo em Inglês | LILACS | ID: biblio-1039507

RESUMO

Abstract The use of new technologies can improve screening in communities with difficult access to health. This article aims to evaluate the sensitivity, specificity, and agreement of a point of care test in comparison to laboratory methods for the determination of glucose (GLI), triglyceride (TG), and total cholesterol (TC) concentrations. This prospective study used data from the remaining adult population of quilombolas in Brazil. Laboratory tests using conventional methods for the analysis of venipuncture samples were used as a standard method to measure the concentrations of GLI (mg/dL), TG (mg/dL), and TC (mg/dL) and compared to the metered dose from the collection of fingertip capillary blood (point of care). Contingency tables (2x2) were used to estimate the sensitivity and specificity of the methods. Lin and Bland & Altman coefficients were used to statistically assess agreement, the level of significance was 5%. There was substantial agreement between the methods for measuring TG and poor agreement for of TC and GLI. Analysis of the Bland & Altman coefficients revealed that the fingertip method did not produce good measures. The point of care method did not offer a good ability to measure compared to that of the reference laboratory method.


Resumo O uso de novas tecnologias pode melhorar o screening em comunidades de difícil acesso à saúde. O objetivo deste artigo é avaliar a sensibilidade, especificidade e concordância do teste de point of care em comparação com método laboratorial para dosagem de Glicose (GLI), Triglicerídeo (TG) e Colesterol total (CT). Estudo prospectivo com dados de população de adultos remanescentes de quilombolas no Brasil. Exames laboratoriais convencionais para análise foram obtidos por venopunção, utilizados como método padrão para mensuração das concentrações de GLI (mg/dL), TG (mg/dL) e CT (mg/dL) e comparados a mensuração por meio de técnica de ponta de dedo (point of care). Tabelas de contingência (2x2) foram utilizadas para estimar sensibilidade e especificidade dos métodos e o coeficiente de Lin e análises de Bland & Altman foram métodos de concordância com nível de significância de 5%. Houve concordância substancial entre os métodos para mensuração de TG e fraca concordância para mensuração de CT e GLI. Os coeficientes de Bland & Altman indicam que o método de ponta de dedo não apresentou boa mensuração. O método point of care não apresentou boa capacidade de mensuração de Glicose, Triglicerídeo e Colesterol total tendo como referência o método laboratorial.


Assuntos
Humanos , Adulto , Idoso , Análise Química do Sangue/métodos , Coleta de Amostras Sanguíneas/métodos , Sistemas Automatizados de Assistência Junto ao Leito , Triglicerídeos/sangue , Glicemia/análise , Brasil , Colesterol/sangue , Estudos Prospectivos , Sensibilidade e Especificidade , Acessibilidade aos Serviços de Saúde , Pessoa de Meia-Idade
3.
Rev. Assoc. Med. Bras. (1992) ; 64(5): 474-480, May 2018. graf
Artigo em Inglês | LILACS | ID: biblio-956469

RESUMO

SUMMARY Point-of-care ultrasonography, which is performed at the bedside by physicians who are not specialists in imaging, has become possible thanks to recent technological advances that have allowed for a device with greater portability while maintaining image quality. The increasing use of point-of-care ultrasonography in different specialties has made it possible to expand physical examinations, make timely decisions about the patients and allows the performance of safer medical procedures. In this review, three cases from our experience are presented that highlight the use of point-of-care ultrasonography by clinicians. Bedside ultrasonography is a convenient modality used in a clinical setting to aid in early diagnosis of several common conditions. It is suggested that a hybrid approach of physical examination and point-of-care ultrasonography in the everyday clinical practice is an inevitable change of paradigm that is improving quality of care in a variety of clinical settings.


Assuntos
Humanos , Masculino , Feminino , Adulto , Idoso , Exame Físico/métodos , Ultrassonografia/métodos , Sistemas Automatizados de Assistência Junto ao Leito , Serviços Médicos de Emergência , Aneurisma da Aorta Abdominal/diagnóstico por imagem , Pessoa de Meia-Idade , Síndrome Nefrótica/diagnóstico por imagem
4.
J. bras. nefrol ; 39(2): 220-223, Apr.-June 2017. graf
Artigo em Inglês | LILACS | ID: biblio-893746

RESUMO

Abstract Introduction: Ultrasonography (US) is a rapid, non-invasive and safe procedure that allows the nephrologist to obtain vital information to the bedside, as well as allows to guide the procedures for nephrology practice. Case report: Male patient, elderly with hypertension, diabetes mellitus and chronic kidney disease presents with infraumbilical protrusion that the Point of Care US (POCUS), performed by the nephrologist, proved to be a large bladder with a diverticulum. In addition, the US enabled the nephrologist to diagnose bilateral hydronephrosis, preservation of the cortico-medullary differentiation and echotexture of the right kidney, post-voiding urinary retention, urinary catheter placement and functional and morphological monitoring of the urinary tract after surgical correction of the infravesical obstruction. Conclusion: POCUS assessment of the renal tract may become the new standard of care among nephrologists by enabling the expansion of clinical information in a timely fashion, allowing faster resolution of cases and permitting the monitoring of the treatment done.


Resumo Introdução: A ultrassonografia (US) é um procedimento rápido, não invasivo e seguro que possibilita ao nefrologista obter informação vital à beira do leito, assim como permite guiar os procedimentos necessários à prática nefrológica. Relato do caso: Paciente masculino, idoso, com hipertensão arterial, diabetes mellitus e doença renal crônica apresenta-se com abaulamento infraumbilical que a Point of Care US (POCUS), realizada pelo nefrologista, mostrou ser um quadro de retenção urinária acompanhado de divertículo vesical. Adicionalmente, a POCUS possibilitou ao nefrologista diagnosticar hidronefrose bilateral, preservação da diferenciação córtico-medular e da ecotextura do rim direito, retenção urinária pós-miccional, correto posicionamento do cateter vesical pós-drenagem e acompanhar funcionalmente e morfologicamente as alterações do trato urinário após a correção da obstrução infravesical. Conclusão: A avaliação do trato urinário na ótica da POCUS eleva a prática nefrológica a um patamar mais alto, ao possibilitar a ampliação de informações clínicas imediatas e à beira do leito, proporcionar maior rapidez na resolução dos casos e permitir o monitoramento do tratamento instituído.


Assuntos
Humanos , Masculino , Idoso , Ultrassonografia , Sistemas Automatizados de Assistência Junto ao Leito , Hidronefrose/diagnóstico por imagem
5.
J. bras. pneumol ; 41(1): 58-64, Jan-Feb/2015. tab, graf
Artigo em Inglês | LILACS | ID: lil-741564

RESUMO

Objective: Bedside lung ultrasound (LUS) is a noninvasive, readily available imaging modality that can complement clinical evaluation. The Bedside Lung Ultrasound in Emergency (BLUE) protocol has demonstrated a high diagnostic accuracy in patients with acute respiratory failure (ARF). Recently, bedside LUS has been added to the medical training program of our ICU. The aim of this study was to investigate the accuracy of LUS based on the BLUE protocol, when performed by physicians who are not ultrasound experts, to guide the diagnosis of ARF. Methods: Over a one-year period, all spontaneously breathing adult patients consecutively admitted to the ICU for ARF were prospectively included. After training, 4 non-ultrasound experts performed LUS within 20 minutes of patient admission. They were blinded to patient medical history. LUS diagnosis was compared with the final clinical diagnosis made by the ICU team before patients were discharged from the ICU (gold standard). Results: Thirty-seven patients were included in the analysis (mean age, 73.2 ± 14.7 years; APACHE II, 19.2 ± 7.3). LUS diagnosis had a good agreement with the final diagnosis in 84% of patients (overall kappa, 0.81). The most common etiologies for ARF were pneumonia (n = 17) and hemodynamic lung edema (n = 15). The sensitivity and specificity of LUS as measured against the final diagnosis were, respectively, 88% and 90% for pneumonia and 86% and 87% for hemodynamic lung edema. Conclusions: LUS based on the BLUE protocol was reproducible by physicians who are not ultrasound experts and accurate for the diagnosis of pneumonia and hemodynamic lung edema. .


Objetivo: O ultrassom pulmonar (USP) à beira do leito é uma técnica de imagem não invasiva e prontamente disponível que pode complementar a avaliação clínica. O protocolo Bedside Lung Ultrasound in Emergency (BLUE, ultrassom pulmonar à beira do leito em situações de emergência) demonstrou elevado rendimento diagnóstico em pacientes com insuficiência respiratória aguda (IRpA). Recentemente, um programa de treinamento em USP à beira do leito foi implementado na nossa UTI. O objetivo deste estudo foi avaliar a acurácia do USP baseado no protocolo BLUE, quando realizado por médicos com habilidades básicas em ultrassonografia, para orientar o diagnóstico de IRpA. Métodos: Ao longo de um ano, todos os pacientes adultos consecutivos respirando espontaneamente admitidos na UTI por IRpA foram prospectivamente inclusos. Após treinamento, 4 operadores com habilidades básicas em ultrassonografia realizaram o USP em até 20 minutos após a admissão na UTI, cegados para a história do paciente. Os diagnósticos do USP foram comparados aos diagnósticos da equipe assistente ao final da internação na UTI (padrão-ouro). Resultados: Foram inclusos na análise 37 pacientes (média etária: 73,2 ± 14,7 anos; APACHE II: 19,2 ± 7,3). O diagnóstico do USP demonstrou concordância com o diagnóstico final em 84% dos casos (kappa total: 0,81). As causas mais comuns de IRpA foram pneumonia (n = 17) e edema pulmonar cardiogênico (n = 15). A sensibilidade e a especificidade do USP comparado ao diagnóstico final foram de 88% e 90% para pneumonia e de 86% e 87% para edema pulmonar cardiogênico, respectivamente. Conclusões: O USP baseado no protocolo BLUE foi reproduzível por médicos com habilidades básicas em ultrassonografia e acurado para o diagnóstico de pneumonia e de edema pulmonar cardiogênico. .


Assuntos
Idoso , Feminino , Humanos , Masculino , Sistemas Automatizados de Assistência Junto ao Leito , Insuficiência Respiratória , Ultrassonografia/métodos , Doença Aguda , APACHE , Brasil , Unidades de Terapia Intensiva , Estudos Prospectivos , Pneumonia/complicações , Pneumonia , Edema Pulmonar/complicações , Edema Pulmonar , Insuficiência Respiratória/classificação , Insuficiência Respiratória/etiologia , Sensibilidade e Especificidade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA