Your browser doesn't support javascript.
loading
Concordância na velocidade da marcha de mulheres diabéticas tipo 2 em diferentes testes de caminhada / Agreement in the gait speed of type 2 diabetic women from different walking tests
Corrêa, Leandro Quadro; Rombaldi, Airton José; Teixeira, Fernanda de Souza; Umpierre, Daniel; Domingues, Marlos Rodrigues.
Afiliação
  • Corrêa, Leandro Quadro; Universidade Federal do Rio Grande. Rio Grande, RS. BR
  • Rombaldi, Airton José; Universidade Federal de Pelotas. Pelotas, RS. BR
  • Teixeira, Fernanda de Souza; Universidade Federal de Pelotas. Pelotas, RS. BR
  • Umpierre, Daniel; Universidade Federal do Rio Grande do Sul. Porto Alegre, RS. BR
  • Domingues, Marlos Rodrigues; Universidade Federal de Pelotas. Pelotas, RS. BR
Rev. bras. ativ. fís. saúde ; 25: 1-8, set. 2020. ilus, tab
Artigo em Português | LILACS | ID: biblio-1141481
Biblioteca responsável: BR12.1
RESUMO
O objetivo desse estudo foi verificar a concordância na velocidade da marcha (VM) a partir dos testes de caminhada de seis minutos (6MWT) e de quatro metros (4MWT) em mulheres diabéticas tipo 2 (DM2). Os testes foram realizados antes e após intervenção de 12 semanas com exercícios físicos. O 4MWT foi realizado em espaço de quatro metros, sendo o resultado do teste medido como o tempo gasto (segundos) no percurso. O 6MWT foi realizado em modelo de ir e vir em uma distância de 15 metros e o resultado foi a distância total (metros) percorrida. Os resultados foram padronizados para velocidade de deslocamento (m/s). Para avaliar a concordância (6MWTpré x 4MWTpré) e (6MWTpósx 4MWTpós), utilizou-se o teste de Bland-Altman (B-A) e o coeficiente de concordância de correlação de Lin. O nível de significância aceito para o estudo foi α 5%. Foram medidas 39 mulheres, com idade média de 58,79 ± 10,03 anos e diagnóstico de DM2 a 8,64 ± 8,53 anos. Verificou-se, pelo teste de B-A, diferenças na VM dos testes de -0,001 ± 0,19 m/s (IC95%: -0,37 a 0,37 m/s) no início e 0,02 ± 0,21 m/s (IC95%: -0,39 a 0,42 m/s) ao final e concordância de 0,60 (IC95%: 0,41 a 0,79; p < 0,001) e 0,52 (IC95%: 0,31 a 0,73; p < 0,001) pré e pós, respectivamente, pelo coeficiente de concordância de correlação Lin. Através dos dados obtidos, sugere-se que os dois testes podem ser utilizados para avaliar a VM das mulheres DM2, porém o 6MWT apresentou maior reprodutibilidade para detectar mudanças na VM ao longo do tempo
ABSTRACT
This study aimed to test the agreement in the gait speed (GS) between the 6-minute walk test and the 4-me-ter gait speed (6MWT - 4MWT) in type 2 diabetic women (T2DM). The tests were performed before and after a 12-week physical exercise intervention. The 4MWT was performed in a space of four meters, with results based on the time spent (seconds) to complete a 4-meter distance. The 6MWT was carried out similar to a yo-yo test in 15 meters and the result was operationalized by the total distance (meters) covered. The results of the tests were standardized as speed (m/s). To evaluate agreements (6MWTbefore x 4MWTbefore) and (6MWTafter x 4MWTafter), Bland-Altman (B-A), and Lin's agreements were used. The level of significance was set at 5%. A total of 39 women were evaluated, mean age 58.79 ± 10.03 years, diagnosis of diabetes at 8.64 ± 8.53 years.The B-A test showed a mean difference in GS of -0.001 ± 0.19 m/s (95%CI: -0.37 to 0.37 m/s) before and 0.02 ± 0.21 m/s (95%CI: -0.39 to 0.42 m/s) after, and Lin's agreements of 0.60 (95%CI: 0.41 to 0.79; p < 0.001) and 0.52 (95%CI: 0.31 to 0.73; p < 0.001) before and after, respectively. Based on our data it is suggested that the two tests can be used to evaluate the GS of T2DM women, but the 6MWT was more reproductible to detect changes in GS over time
Assuntos


Texto completo: Disponível Coleções: Bases de dados internacionais Indicadores: Indicadores_desigualdade_saude Temas: Saúde do idoso Base de dados: LILACS Assunto principal: Diabetes Mellitus Tipo 2 / Teste de Caminhada / Análise da Marcha Idioma: Português Revista: Rev. bras. ativ. fís. saúde Assunto da revista: Medicina Esportiva Ano de publicação: 2020 Tipo de documento: Artigo País de afiliação: Brasil Instituição/País de afiliação: Universidade Federal de Pelotas/BR / Universidade Federal do Rio Grande do Sul/BR / Universidade Federal do Rio Grande/BR

Similares

MEDLINE

...
LILACS

LIS


Texto completo: Disponível Coleções: Bases de dados internacionais Indicadores: Indicadores_desigualdade_saude Temas: Saúde do idoso Base de dados: LILACS Assunto principal: Diabetes Mellitus Tipo 2 / Teste de Caminhada / Análise da Marcha Idioma: Português Revista: Rev. bras. ativ. fís. saúde Assunto da revista: Medicina Esportiva Ano de publicação: 2020 Tipo de documento: Artigo País de afiliação: Brasil Instituição/País de afiliação: Universidade Federal de Pelotas/BR / Universidade Federal do Rio Grande do Sul/BR / Universidade Federal do Rio Grande/BR