1.
Chest ; 146(5): e160-e162, 2014 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-25367483

RESUMO

A 70-year-old man underwent total hip replacement surgery under general anesthesia, endotracheal intubation, and controlled ventilation, with the patient in left lateral position. Intraoperatively, the patient was hemodynamically stable, with a normal range of pulse, ECG trace, oxygen saturation as measured by pulse oximetry (Spo2), and end-tidal CO2 (etco2). Five minutes after insertion of the hip prosthesis, his heart rate dropped to 30 beats/min, BP to 40/30 mm Hg, Spo2 to 70%, and etco2 to 10 mm Hg.


Assuntos
Artroplastia de Quadril/efeitos adversos , Cimentos Ósseos/efeitos adversos , Embolia/complicações , Hipotensão/etiologia , Hipóxia/etiologia , Complicações Intraoperatórias , Idoso , Diagnóstico Diferencial , Ecocardiografia Transesofagiana , Eletrocardiografia , Embolia/diagnóstico , Evolução Fatal , Frequência Cardíaca , Humanos , Hipotensão/diagnóstico , Hipóxia/diagnóstico , Masculino , Oximetria , Radiografia Torácica , Síndrome