Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 12 de 12
Filtrar
1.
Europace ; 25(3): 1110-1115, 2023 03 30.
Artigo em Inglês | MEDLINE | ID: mdl-36504239

RESUMO

AIMS: The ideal pacing strategy has been the Achilles' heel for patients with congenitally corrected transposition of great arteries (ccTGA) with bradycardia. Various pacing modalities were documented in the literature. This article describes a novel pacing strategy and its feasibility in ccTGA with an intact ventricular septum. METHODS AND RESULTS: We prospectively recruited three patients with ccTGA who presented with symptomatic complete heart block to our institute and were evaluated. All patients were planned for conduction system pacing. Those who had more than moderate or severe systemic atrioventricular regurgitation and systemic ventricular dysfunction were planned for conduction system pacing with an additional lead in the coronary sinus (CS) tributary, i.e. bundle branch pacing optimized cardiac resynchronization therapy with the intention to achieve incremental benefit. Since right bundle pacing is not described previously and in view of anatomical complexity in location, three-dimensional (3D) anatomical mapping was done with the EnSite system and later right bundle capture is identified conventionally as that of a left bundle in a normal heart. All three patients have stable lead positions and adequate thresholds at short-term follow-up. CONCLUSION: In this report, we demonstrated the feasibility of permanent physiological pacing of the systemic ventricle by capturing the right bundle with 3D anatomical mapping guidance, which results in physiological activation of the systemic ventricle.


Assuntos
Terapia de Ressincronização Cardíaca , Septo Interventricular , Humanos , Transposição das Grandes Artérias Corrigida Congenitamente , Septo Interventricular/diagnóstico por imagem , Estimulação Cardíaca Artificial/métodos , Sistema de Condução Cardíaco , Terapia de Ressincronização Cardíaca/métodos , Doença do Sistema de Condução Cardíaco , Artérias , Fascículo Atrioventricular , Eletrocardiografia
3.
Echocardiography ; 37(2): 337-346, 2020 02.
Artigo em Inglês | MEDLINE | ID: mdl-32112483

RESUMO

INTRODUCTION: Systemic venous flow patterns become abnormal and restrictive after surgical closure of ostium secundum atrial septal defect (ASD) but rarely studied after percutaneous device closure. METHODS: From January 2017 to January 2018, systemic venous Doppler flow patterns were documented prospectively in 50 subjects who underwent percutaneous closure of ASD, prior to, after procedure, and at 6-month follow-up and correlated with defect size and device size. RESULTS: In hepatic veins and superior venacava post device-closure closure, the velocity time integral (VTI) of forward flow in both systole (S) and diastole (D) increased. Overall S was higher than D, and D/S ratio was <1. The D/S ratio increased after device closure significantly reflecting that the improvement in atrial filling increase in diastolic flow more than the increase in systolic flow. Increase in flow velocities was more prominent at 6 months with further increase in D/S VTI ratios. When correlated with the defect size, in those with defect size less than 15 mm/sq.m (mean device size 13.05 ± 3.21 mm), the changes in S- or D-wave, D/S ratio were less prominent and statistically not significant, while in subjects with defect size ≥ 15 mm/sq.m (mean device size 23.02 (±4.77 mm), these changes were greater and statistical significant. CONCLUSION: Residual filling defects with restriction of systolic venous flow were observed in subjects after device closure, correlating with larger device sizes, implying the compliance abnormality conferred by them which progresses at 6 months. Subjects with persistent abnormalities would need careful follow up for incomplete remodeling and increase in atrial size related arrhythmias.


Assuntos
Apêndice Atrial , Comunicação Interatrial , Cateterismo Cardíaco , Átrios do Coração/diagnóstico por imagem , Comunicação Interatrial/diagnóstico por imagem , Comunicação Interatrial/cirurgia , Humanos , Resultado do Tratamento
4.
J Arrhythm ; 40(1): 154-155, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38333382

RESUMO

This electrophysiological tracing localizes the level of block distal to the recorded Mahaim potential during bump termination mapping of an atriofascicular pathway at the tricuspid annulus.

5.
J Arrhythm ; 40(1): 148-149, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38333393

RESUMO

This electrophysiology tracing demonstrates a graded postexcitation response of the retrograde limb of an orthodromic reentrant tachycardia circuit with varying His refractory VPB coupling intervals, which reiterates the decrementally conducting retrograde limb of the tachycardia circuit.

6.
J Arrhythm ; 40(2): 385-389, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38586858

RESUMO

Background: Diagnosing myocarditis in children presenting with complete AV block (CAVB) is challenging. Temporary permanent pacing support using standard transvenous active fixation lead can be inserted percutaneously until recovery. However, access to cardiac magnetic resonance (CMR) imaging may be limited due to safety concerns. Cases: We report three cases where CMR was performed using temporary permanent pacemaker in situ. We evaluated the effect of device artefacts on image quality and examined any instances of device malfunction. Conclusion: In children with CAVB and myocarditis, a temporary permanent pacemaker can provide reliable pacing until recovery, and CMR can be safely performed with the implanted pacemaker without compromising image quality.

7.
Heart Rhythm ; 21(6): 893-900, 2024 06.
Artigo em Inglês | MEDLINE | ID: mdl-38367889

RESUMO

BACKGROUND: Cardiac resynchronization therapy (CRT) is typically attempted with biventricular (BiV) pacing. One-third of patients are nonresponders. Left bundle branch area pacing (LBBAP) has been evaluated as an alternative means. OBJECTIVE: The purpose of this study was to assess the feasibility and clinical response of permanent LBBAP as an alternative to BiV pacing. METHODS: Of 479 consecutive patients referred with heart failure, 50 with BiV-CRT and 51 with LBBAP-CRT were included in this analysis after study exclusions. Quality-of-Life (QoL) assessments, echocardiographic measurements, and New York Heart Association (NYHA) class were obtained at baseline and at 6-monthly intervals. RESULTS: There were no differences in baseline characteristics between groups (all P > .05). Clinical outcomes such as left ventricular ejection fraction, left ventricular end-systolic volume, QoL, and NYHA class were significantly improved for both pacing groups compared to baseline. The LBBAP-CRT group showed greater improvement in left ventricular ejection fraction at 6 months (P = .001) and 12 months (P = .021), accompanied by greater reduction in left ventricular end-systolic volume (P = .007). QRS duration < 120 ms (baseline 160.82 ± 21.35 ms vs 161.08 ± 24.48 ms) was achieved in 30% in the BiV-CRT group vs 71% in the LBBAP-CRT group (P ≤ .001). Improvement in NYHA class (P = .031) and QoL index was greater (P = .014). Reduced heart failure admissions (P = .003) and health care utilization (P < .05) and improved lead performance (P < .001) were observed in the LBBAP-CRT group. CONCLUSION: LBBAP-CRT is feasible and effective CRT. It results into a meaningful improvement in QoL and reduction in health care utilization. This can be offered as an alternative to BiV-CRT or potentially as first-line therapy.


Assuntos
Terapia de Ressincronização Cardíaca , Insuficiência Cardíaca , Qualidade de Vida , Volume Sistólico , Humanos , Masculino , Feminino , Terapia de Ressincronização Cardíaca/métodos , Insuficiência Cardíaca/terapia , Insuficiência Cardíaca/fisiopatologia , Idoso , Resultado do Tratamento , Volume Sistólico/fisiologia , Fascículo Atrioventricular/fisiopatologia , Função Ventricular Esquerda/fisiologia , Ecocardiografia , Pessoa de Meia-Idade , Bloqueio de Ramo/terapia , Bloqueio de Ramo/fisiopatologia , Seguimentos , Eletrocardiografia
8.
Heart Rhythm ; 21(10): 1970-1977, 2024 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-38636932

RESUMO

BACKGROUND: Endocardial electrogram (EGM) characteristics in nonischemic cardiomyopathy (NICM) have not been explored adequately for prognostication. OBJECTIVE: We aimed to study correlation of bipolar and unipolar EGM characteristics with left ventricular ejection fraction (LVEF) and ventricular tachycardia (VT) in NICM. METHODS: Electroanatomic mapping of the left ventricle was performed. EGM characteristics were correlated with LVEF. Differences between groups with and without VT and predictors of VT were studied. RESULTS: In 43 patients, unipolar EGM variables had better correlation with baseline LVEF than bipolar EGM variables: unipolar voltage (r = +0.36), peak negative unipolar voltage (r = -0.42), peak positive unipolar voltage (r = +0.38), and percentage area of unipolar low-voltage zone (LVZ; r = -0.41). Global mean unipolar voltage (hazard ratio [HR], 0.4; 95% confidence interval [CI], 0.2-0.8), extent of unipolar LVZ (HR, 1.6; 95% CI, 1.1-2.3), and percentage area of unipolar LVZ (HR, 1.6; 95% CI, 1.1-2.3) were significant predictors of VT. For classification of patients with VT, extent of unipolar LVZ had an area under the curve of 0.82 (95% CI, 0.69-0.95; P < .001), and percentage area of unipolar LVZ had an area under the curve of 0.83 (95% CI, 0.71-0.96; P = .01). Cutoff of >3 segments for extent of unipolar LVZ had the best diagnostic accuracy (sensitivity, 90%; specificity, 67%) and cutoff of 33% for percentage area of unipolar LVZ had the best diagnostic accuracy (sensitivity, 95%; specificity, 60%) for VT. CONCLUSION: In NICM, extent and percentage area of unipolar LVZs are significant predictors of VT. Cutoffs of >3 segments of unipolar LVZ and >33% area of unipolar LVZ have good diagnostic accuracies for association with VT.


Assuntos
Cardiomiopatias , Endocárdio , Ventrículos do Coração , Taquicardia Ventricular , Humanos , Taquicardia Ventricular/fisiopatologia , Taquicardia Ventricular/diagnóstico , Masculino , Feminino , Cardiomiopatias/fisiopatologia , Cardiomiopatias/diagnóstico , Cardiomiopatias/complicações , Pessoa de Meia-Idade , Ventrículos do Coração/fisiopatologia , Ventrículos do Coração/diagnóstico por imagem , Endocárdio/fisiopatologia , Volume Sistólico/fisiologia , Idoso , Função Ventricular Esquerda/fisiologia , Mapeamento Potencial de Superfície Corporal/métodos
9.
Heart Rhythm ; 2024 Sep 13.
Artigo em Inglês | MEDLINE | ID: mdl-39278609

RESUMO

BACKGROUND: Paced QRS morphology may vary during left bundle branch area pacing (LBBAP) per the pacing location. It remains unclear whether electrocardiographic changes observed during LBBAP can predict clinical outcomes. OBJECTIVE: We aimed to assess correlation between characteristics of paced QRS on the electrocardiogram and clinical outcomes in heart failure patients with nonischemic cardiomyopathy. METHODS: Of 79 consecutive heart failure patients receiving LBBAP, 59 patients were included in this prospective study after exclusions. LBBAP was performed using Medtronic 3830 lead. Patients were assigned to various groups on the basis of paced QRS morphology in lead V1 (qR and Qr), QRS axis (normal, left, or right), and V6 R-wave peak time (RWPT, ≤80 ms or >80 ms) to compare echocardiographic outcomes. RESULTS: RWPT was significantly shorter (75.7 ± 17.5 ms vs 85.3 ± 11.3 ms; P = .014), transition during threshold testing was more commonly observed (81.5% vs 53%; P = .02), and improvement in left ventricular ejection fraction (LVEF) was significantly greater in the qR group (21.4% ± 6.4% vs 16.4% ± 8.3%; P = .013) compared with the Qr group. RWPT or LVEF did not differ in patients with different paced QRS axis (P > .05). Whereas qR morphology and presence of transition during threshold testing independently predicted LVEF improvement, RWPT lacked predictive value. Nonresponders had greater incidence of loss of R' (P = .009) and prolonged RWPT (P = .003) on follow-up compared with average responders and superresponders. CONCLUSION: Paced qR morphology and transition during threshold testing predicted greater improvement in LVEF, whereas RWPT lacked predictive value. Loss of terminal R in lead V1 and prolongation of RWPT on follow-up prognosticated nonresponse to LBBAP.

10.
Indian J Radiol Imaging ; 33(4): 563-566, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-37811179

RESUMO

Coronary involvement in Kawasaki disease is not uncommon; however, giant coronary aneurysm exceeding 50 mm is extremely rare. In this article, we presented a case of giant coronary aneurysm involving right coronary artery with associated asymptomatic myocardial ischemia as evident by multimodality imaging.

11.
J Interv Card Electrophysiol ; 64(1): 137-148, 2022 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-35084617

RESUMO

BACKGROUND: Localisation of the conduction system under fluoroscopy is not easy and the ideal location of the pacing leads in physiological pacing is still being debated. OBJECTIVE: The primary aim was to assess the lead locations using cardiac CT scan. Secondary aims were clinical outcomes including success and safety of the procedure and lead performance. METHODS: Of the 100 consecutive patients who received physiological pacing, 34 patients underwent follow-up cardiac CT scan. The four different types of pacing were identified as His bundle (HBP), para-Hisian, left bundle branch (LBBP), and deep septal pacing. RESULTS: Most patients had successful HBP via the right atrium (RA) (87.5%) as compared to the right ventricle (RV) (12.5%). Lower thresholds were observed when leads were placed within 2 mm of the junction of the membranous and muscular ventricular septum. Unlike HBP, LBBP was possible at a wide region of the septum and selective capture of individual fascicles was feasible. LBBP showed deeper penetration of leads into the septum, as compared to deep septal pacing (70% vs. 45%). Approximately, 80% of patients did not have an intra-ventricular portion of the membranous septum. CONCLUSIONS: The anterior part of the atrio-ventricular (AV) septum at the junction between the membranous and muscular septum via RA appeared to be the best target to successfully pace His bundle. LBBP was possible at a wide region of the septum and selective capture of individual fascicle was feasible. Adequate depth of penetration of lead was very important to capture the left bundle.


Assuntos
Fascículo Atrioventricular , Estimulação Cardíaca Artificial , Fascículo Atrioventricular/diagnóstico por imagem , Estimulação Cardíaca Artificial/métodos , Eletrocardiografia/métodos , Humanos , Tomografia , Tomografia Computadorizada por Raios X , Resultado do Tratamento
12.
Ann Pediatr Cardiol ; 9(3): 251-3, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-27625525

RESUMO

A 44-year-old woman presented with features of congestive heart failure. Echocardiography revealed severe right ventricular dysfunction along with passive minimally pulsatile pulmonary blood flow suggesting very high systemic venous pressures. This was confirmed with cardiac catheterization in which the pressures of superior vena cava and inferior vena cava (19 mmHg) were higher than the pulmonary artery pressures (17 mmHg). Elevation of systemic venous pressures above the pulmonary venous pressures, Fontan paradox, to drive the forward flow, is a specific feature of artificially created cavopulmonary shunts. Late stage of isolated right ventricular cardiomyopathy resulted in the spontaneous evolution of Fontan circulation with a nonfunctional right ventricle in this patient.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA