Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
Bioanalysis ; 11(12): 1157-1169, 2019 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-31241345

RESUMO

Aim: Reliable quantitative LC-MS methodology has been established and validated for an oligonucleotide in plasma in a fresh and unique fashion, free of ion-pairing reagents and the various associated deleterious effects from primary solution preparation through sample preparation and extraction to the LC-MS analytical end point, offering a highly selective mixed-mode solid-phase extraction with hydrophilic-interaction liquid chromatography as the chromatographic element prior to SRM detection. Results: Inter- and intra-assay accuracy and precision ranged from 97.9 to 111% and 2.75 to 9.66%, respectively. Recoveries of 50% were attained, and there was no significant matrix effect manifestation. Conclusion: The method demonstrated rugged performance and reliability under the optimized conditions, indicating a possible exciting new avenue, free of ion-pairing, for general application in oligonucleotide quantitative LC-MS.


Assuntos
Cromatografia Líquida/métodos , Oligonucleotídeos/análise , Métodos Analíticos de Preparação de Amostras , Sequência de Bases , Calibragem , Humanos , Interações Hidrofóbicas e Hidrofílicas , Oligonucleotídeos/sangue , Oligonucleotídeos/química , Oligonucleotídeos/genética
2.
Bioanalysis ; 8(21): 2195-2203, 2016 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-27678052

RESUMO

AIM: This work set out to realize an idea for a novel means of extracting the peptide therapeutic bivalirudin from human plasma in what would be a uniquely selective means of SPE, a mixed-mode protocol involving electrostatic interactions followed by HILIC. RESULTS: Inter and intra-assay relative error ranged from 3.52 to 8.23%, and 2.37 to 6.90%, respectively. Inter and intra-assay precision ranged from 2.64 to 7.12%, and 0.855 to 2.90%, respectively. Recoveries of 80% were attained, and there was no hint of discernible manifestation of matrix effects. CONCLUSION: The method was shown to perform excellently in the assessment tantamount to method validation. The essence of the extraction method presents a new option for highly selective extraction of peptides from biological matrices.


Assuntos
Análise Química do Sangue/métodos , Hirudinas/sangue , Fragmentos de Peptídeos/sangue , Espectrometria de Massas em Tandem/normas , Análise Química do Sangue/instrumentação , Calibragem , Cromatografia Líquida de Alta Pressão/normas , Hirudinas/isolamento & purificação , Hirudinas/normas , Humanos , Interações Hidrofóbicas e Hidrofílicas , Fragmentos de Peptídeos/isolamento & purificação , Fragmentos de Peptídeos/normas , Proteínas Recombinantes/sangue , Proteínas Recombinantes/isolamento & purificação , Proteínas Recombinantes/normas , Extração em Fase Sólida , Eletricidade Estática
3.
Bioanalysis ; 5(4): 415-22, 2013 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-23414375

RESUMO

BACKGROUND: It was desired to use contemporary knowledge and technology to develop a highly selective and reliable LC-MS/MS method for teriparatide in human plasma to begin to supplant existing ELISA methodologies. RESULTS: The method was developed using SPE of intact teriparatide and the internal standard rat analogue parathyroid hormone fragment 1-34 from human plasma, and UPLC-MS/MS analysis. Inter- and intra-batch accuracy and precision ranged from 97.5 to 109%, and 1.78 to 12.4%, respectively. Mean analyte extraction recoveries of 80% were attained. CONCLUSION: All relevant acceptance criteria were met in a procedure akin to method validation without the stability aspects, and with a basis of excellent signal stability all performance aspects of the method were unassailable.


Assuntos
Cromatografia Líquida/métodos , Extração em Fase Sólida/métodos , Espectrometria de Massas em Tandem/métodos , Teriparatida/sangue , Humanos , Reprodutibilidade dos Testes
4.
Bioanalysis ; 4(24): 2877-86, 2012 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-23244279

RESUMO

BACKGROUND: An investigation was carried out into the chromatographic behavior, on a silica hydride-based phase and a comparator silica-based phase, of an important group of lipids endogenous to human plasma, which are associated with matrix effect and in the context of quantitative peptide analysis. RESULTS: The propensity for aqueous normal phase (ANP) retention on the silica hydride-based phase was strong and extensive in comparison with the silica-based comparator, and the lipophilic interferences in question were readily eluted using the ANP mode, a contrast to over-retention issues with accompanying implications for method ruggedness typically found with silica-based phases. CONCLUSION: The silica hydride-based phase, with ANP operation, offered selectivity conducive to rapid lipophilic interferent elimination and the bimodal retention involved in suitable gradient elution was appropriate for general peptide analytical application.


Assuntos
Análise Química do Sangue/métodos , Cromatografia Líquida de Alta Pressão/métodos , Silicatos/química , Espectrometria de Massas em Tandem/métodos , Humanos , Lipídeos/sangue
5.
Bioanalysis ; 4(10): 1163-73, 2012 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-22651560

RESUMO

BACKGROUND: In the context of matrix effects in bioanalytical LC-MS/MS, a speculative link between free cholesterol, the recoveries of the compound from three common extraction procedures, and response enhancement was qualitatively investigated. RESULTS: Injections on-column of cholesterol both in solution and extracts, in conjunction with post-column infusion of three representative drugs, reveal a direct role in pronounced response enhancement for two out of three analytes, under one set of LC-MS/MS conditions, for the majority of typical plasma extraction procedures, where electrospray-based gaseous ion generation is used. CONCLUSION: Cholesterol has been shown to have a strong association with LC-MS/MS response enhancement and ideally should be monitored during method development, reinforcing the reasoning behind minimizing SPE elution volumes and avoiding less selective means of sample preparation.


Assuntos
Colesterol/análise , Colesterol/química , Cromatografia Líquida/métodos , Extração em Fase Sólida/métodos , Espectrometria de Massas em Tandem/métodos , Animais , Cicloexanóis/sangue , Cicloexanóis/química , Humanos , Cetoconazol/sangue , Cetoconazol/química , Extração Líquido-Líquido , Preparações Farmacêuticas/sangue , Preparações Farmacêuticas/química , Plasma/química , Ratos , Triazóis/sangue , Triazóis/química , Triptaminas/sangue , Triptaminas/química , Cloridrato de Venlafaxina
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA