1.
J Card Surg ; 37(2): 297-304, 2022 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-34672025

RESUMO

BACKGROUND: Frailty influences the postoperative outcomes in patients undergoing left ventricular assist device (LVAD) implantation. Recently, erector spinae muscle (ESM) mass has been proposed as a parameter to assess frailty accurately. Thus, the purpose of the present study was to evaluate whether preoperative ESM mass is associated with short- and long-term clinical outcomes in patients with LVAD. METHODS: A total of 119 consecutive patients with LVAD were enrolled between January 2010 and October 2017 at a single heart center. The ESM area, ESM index, and Hounsfield units (HU) of the ESM were calculated by computed tomography for preoperative ESM mass evaluation. We then statistically evaluated the in-hospital mortality, major adverse cardiovascular events (MACE), duration of hospital stay, and long-term survival. RESULTS: In a multivariate Cox regression analysis, ESM mass indicated no effect on all clinical outcomes. In addition, the ESM area presented a weak but significant negative linear correlation only with the duration of hospital stay (r = -0.21, p < .05). In contrast, the Model For End-stage Liver Disease (MELD) score and preoperative venous-arterial extracorporeal membrane oxygenation (va-ECMO) were significant predictive factors for in-hospital mortality (MELD score: p < .001, hazard ratio [HR] 1.1; preoperative va-ECMO: p < .01, HR 2.72) and MACE (MELD score: p < .001, HR 1.07; preoperative va-ECMO: p < .005, HR 2.62). CONCLUSION: Preoperative ESM mass might predict the length of hospital stay in patients undergoing LVAD implantation. In contrast, it had no effect on MACE, in-hospital mortality, or long-term survival in this study.


Assuntos
Doença Hepática Terminal , Insuficiência Cardíaca , Coração Auxiliar , Insuficiência Cardíaca/terapia , Humanos , Músculos , Estudos Retrospectivos , Índice de Gravidade de Doença , Resultado do Tratamento
2.
Int J Legal Med ; 135(5): 1869-1878, 2021 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-33629138

RESUMO

INTRODUCTION: Postmortem multi-detector computed tomography (PMCT) has become an important part in forensic imaging. Modern reconstruction techniques such as iterative reconstruction (IR) are frequently used in postmortem CT angiography (PMCTA). The image quality of PMCTA depends on the strength of IR. For this purpose, we aimed to investigate the impact of different advanced IR levels on the objective and subjective PMCTA image quality. MATERIAL AND METHODS: We retrospectively analyzed the coronary arteries of 27 human cadavers undergoing whole-body postmortem CT angiography between July 2017 and March 2018 in a single center. Iterative reconstructions of the coronary arteries were processed in five different level settings (0%; 30%; 50%; 70%; 100%) by using an adaptive statistical IR method. We evaluated the objective (contrast-to-noise ratio (CNR)) and subjective image quality in several anatomical locations. RESULTS: Our results demonstrate that the increasing levels of an IR technique have relevant impact on the image quality in PMCTA scans in forensic postmortem examinations. Higher levels of IR have led to a significant reduction of image noise and therefore to a significant improvement of objective image quality (+ 70%). However, subjective image quality is inferior at higher levels of IR due to plasticized image appearance. CONCLUSION: Objective image quality in PMCTA progressively improves with increasing level of IR with the best CNR at the highest IR level. However, subjective image quality is best at low to medium levels of IR. To obtain a "classic" image appearance with optimal image quality, PMCTAs should be reconstructed at medium levels of IR.


Assuntos
Angiografia por Tomografia Computadorizada , Vasos Coronários/diagnóstico por imagem , Aumento da Imagem/métodos , Processamento de Imagem Assistida por Computador/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Autopsia , Cadáver , Meios de Contraste , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Razão Sinal-Ruído
3.
Neuroradiology ; 63(12): 2073-2085, 2021 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-34019112

RESUMO

PURPOSE: Parkinson's disease (PD) is primarily defined by motor symptoms and is associated with alterations of sensorimotor areas. Evidence for network changes of the sensorimotor network (SMN) in PD is inconsistent and a systematic evaluation of SMN in PD yet missing. We investigate functional connectivity changes of the SMN in PD, both, within the network, and to other large-scale connectivity networks. METHODS: Resting-state fMRI was assessed in 38 PD patients under long-term dopaminergic treatment and 43 matched healthy controls (HC). Independent component analysis (ICA) into 20 components was conducted and the SMN was identified within the resulting networks. Functional connectivity within the SMN was analyzed using a dual regression approach. Connectivity between the SMN and the other networks from group ICA was investigated with FSLNets. We investigated for functional connectivity changes between patients and controls as well as between medication states (OFF vs. ON) in PD and for correlations with clinical parameters. RESULTS: There was decreased functional connectivity within the SMN in left inferior parietal and primary somatosensory cortex in PD OFF. Across networks, connectivity between SMN and two motor networks as well as two visual networks was diminished in PD OFF. All connectivity decreases partially normalized in PD ON. CONCLUSION: PD is accompanied by functional connectivity losses of the SMN, both, within the network and in interaction to other networks. The connectivity changes in short- and long-range connections are probably related to impaired sensory integration for motor function in PD. SMN decoupling can be partially compensated by dopaminergic therapy.


Assuntos
Doença de Parkinson , Córtex Sensório-Motor , Mapeamento Encefálico , Humanos , Imageamento por Ressonância Magnética , Vias Neurais/diagnóstico por imagem , Doença de Parkinson/diagnóstico por imagem , Doença de Parkinson/tratamento farmacológico , Córtex Sensório-Motor/diagnóstico por imagem
4.
J Radiol Prot ; 40(3): 877-891, 2020 09.
Artigo em Inglês | MEDLINE | ID: mdl-32604085

RESUMO

OBJECTIVES: The detection of Coronavirus Disease 2019 (COVID-19) by reverse transcription polymerase chain reaction (RT-PCR) has varying sensitivity. Computed tomography (CT) of the chest can verify infection in patients with clinical symptoms and a negative test result, accelerating treatment and actions to prevent further contagion. However, CT employs ionising radiation. The purpose of this study was to evaluate protocol settings, associated radiation exposure, image quality and diagnostic performance of a low-dose CT protocol in a university hospital setting. MATERIALS AND METHODS: Chest CT examinations were performed on a single scanner (Somatom Definition Edge, Siemens Healthineers, Germany) in 105 symptomatic patients (60 male, 45 female). Images were evaluated with regard to protocol parameters, image quality, radiation exposure and diagnostic accuracy. Serial RT-PCR served as the standard of reference. Based on this reference standard sensitivity, specificity, positive and negative predictive values of CT with 95% confidence interval were calculated. RESULTS: The mean effective dose was 1.3 ± 0.4 mSv (0.7-2.9 mSv) for the patient cohort (mean age 66.6 ± 16.7 years (19-94 years), mean body mass index (BMI) 26.6 ± 5.3 kg m-2 (16-46 kg/m2)). A sensitivity of 100 [95% CI: 82-100]%, a specificity of 78 [95% CI: 68-86]%, a positive predictive value of 50 [95% CI: 33-67]% and a negative predictive value of 100 [95% CI: 95-100]% were obtained. No COVID-19 diagnoses were missed by CT. Image noise did not strongly correlate with BMI or patient diameter and was rated as average. CONCLUSIONS: We presented a robust imaging procedure with a chest CT protocol for confident diagnosis of COVID-19. Even for an overweight patient cohort, an associated radiation exposure of only 1.3 ± 0.4 mSv was achieved with sufficient diagnostic quality to exclude COVID-19.


Assuntos
Infecções por Coronavirus/diagnóstico por imagem , Pneumonia Viral/diagnóstico por imagem , Doses de Radiação , Radiografia Torácica/normas , Tomografia Computadorizada por Raios X/normas , Adulto , Idoso , Idoso de 80 Anos ou mais , Betacoronavirus , COVID-19 , Feminino , Hospitais Universitários , Humanos , Masculino , Pessoa de Meia-Idade , Pandemias , Valor Preditivo dos Testes , Reação em Cadeia da Polimerase Via Transcriptase Reversa , SARS-CoV-2 , Sensibilidade e Especificidade
5.
J Radiol Prot ; 40(1): 68-82, 2020 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-31604340

RESUMO

PURPOSE: To develop size-specific institutional diagnostic reference levels (DRLs) for computed tomography (CT) protocols used in neck CT imaging (cervical spine CT, cervical CT angiography (CTA) and cervical staging CT) and to compare institutional to national DRLs. MATERIALS AND METHODS: Cervical CT examinations (spine, n = 609; CTA, n = 505 and staging CT, n = 184) performed between 01/2016 and 06/2017 were included in this retrospective study. For each region and examination, the volumetric CT dose index (CTDIvol) and dose-length product (DLP) were determined and binned into size bins according to patient water-equivalent diameter (dw). Linear regression analysis was performed to calculate size-specific institutional DRLs for CTDIvol and DLP, applying the 75th percentile as the upper limit for institutional DRLs. The mean institutional CTDIvol and DLP were compared to national DRLs (CTDIvol 20 mGy for cervical spine CT (DLP 300 mGycm) and cervical CTA (DLP 600 mGycm), and CTDIvol 15 mGy for cervical staging CT (DLP 330 mGycm)). RESULTS: The mean CTDIvol and DLP (±standard deviation) were 15.2 ± 4.1 mGy and 181.5 ± 88.3 mGycm for cervical spine CT; 8.1 ± 4.3 mGy and 280.2 ± 164.3 mGycm for cervical CTA; 8.6 ± 1.9 mGy and 162.8 ± 85.0 mGycm for cervical staging CT. For all CT protocols, there was a linear increase in CTDIvol and DLP with increasing dw. For the CTDIvol, size-specific institutional DRLs increased with dw from 14 to 29 mGy for cervical spine CT, from 5 to 17 mGy for cervical CTA and from 8 to 13 mGy for cervical staging CT. For the DLP, size-specific institutional DRLs increased with dw from 130 to 510 mGycm for cervical spine CT, from 140 to 640 mGycm for cervical CTA and from 140 to 320 mGycm for cervical staging CT. Institutional DRLs were lower than national DRLs by 81% and 67% for cervical spine CT (dw = 17.8 cm), 43% and 51% for cervical CTA (dw = 19.5 cm) and 59% and 53% for cervical staging CT (dw = 18.8 cm) for CTDIvol and DLP, respectively. CONCLUSION: Size-specific institutional DRLs were generated for neck CT examinations. The mean institutional CTDIvol and DLP values were well below national DRLs.


Assuntos
Níveis de Referência de Diagnóstico , Pescoço/diagnóstico por imagem , Tomografia Computadorizada por Raios X , Angiografia por Tomografia Computadorizada , Humanos , Doses de Radiação , Estudos Retrospectivos
6.
Pediatr Radiol ; 48(7): 1008-1012, 2018 07.
Artigo em Inglês | MEDLINE | ID: mdl-29651606

RESUMO

BACKGROUND: Diffusion-weighted magnetic resonance imaging with apparent diffusion coefficient (ADC) calculation is important for detecting bone marrow pathologies. OBJECTIVE: To investigate age-related differences of lumbar vertebral body ADC to establish normal values for healthy children. MATERIALS AND METHODS: Forty-nine healthy children without any history of oncological or hematological diseases (10.2±4.7 years, range: 0-20 years) were included in this retrospective study. All magnetic resonance imaging (MRI) examinations were performed at 1.5 T and with similar scan parameters. The diffusion-weighted sequences were performed with b values of 50, 400 and 800 s/mm2. ADC values were measured by placing regions of interest at three different levels within each lumbar vertebral body (L1 to L5). ADC values were analyzed for different age groups (0-2 years, 3-6 years, 7-11 years, 12-14 years, 15-20 years), for each vertebral and intravertebral level. RESULTS: The mean ADC of the whole study group was 0.60±0.09 × 10-3 mm2/s. Children between the ages of 12 and 14 years had significantly higher ADC compared to the other age groups (P≤0.0003). ADC values were significantly higher in the 1st lumbar vertebral body compared to the other levels of the lumbar spine (P<0.005) with the exception of L5, and in the upper third of the vertebral bodies compared to the middle or lower thirds (P≤0.003). CONCLUSION: The age-, vertebral- and intravertebral level-dependent differences in ADC suggest a varying composition and cellularity in different age groups and in different locations.


Assuntos
Medula Óssea/diagnóstico por imagem , Vértebras Lombares/diagnóstico por imagem , Adolescente , Fatores Etários , Criança , Pré-Escolar , Imagem de Difusão por Ressonância Magnética/métodos , Feminino , Humanos , Lactente , Recém-Nascido , Masculino , Valores de Referência , Estudos Retrospectivos , Adulto Jovem
7.
J Radiol Prot ; 38(2): 536-548, 2018 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-29261100

RESUMO

Size-specific institutional diagnostic reference levels (DRLs) were generated for chest and abdominopelvic computed tomography (CT) based on size-specific dose estimates (SSDEs) and depending on patients' water-equivalent diameter (Dw). 1690 CT examinations were included in the IRB-approved retrospective study. SSDEs based on the mean water-equivalent diameter of the entire scan volume were calculated automatically. SSDEs were analyzed for different patient sizes and institutional DRLs (iDRLS; 75% percentiles) based on Dw and SSDEs were generated. iDRLs were compared to the national DRLs. Mean volumetric computed tomography dose index (CTDIvol), Dw and SSDEs for all 1690 CT examinations were 7.2 ± 4.0 mGy (0.84-47.9 mGy), 29.0 ± 3.4 cm and 8.5 ± 3.8 mGy (1.2-37.7 mGy), respectively. Overall, the mean SSDEs of all CT examinations were higher than the CTDIvol in chest CT, abdominopelvic CT and upper abdominal CT, respectively (p < 0.001 for all). There was a strong linear correlation between Dw and SSDEs in chest (R2 = 0.66), abdominopelvic (R2 = 0.98) and upper abdominal CT (R2 = 0.96) allowing for the implementation of size-specific institutional DRLs based on SSDEs and patients' Dw. We generated size-specific, Dw-dependent institutional DRLs based on SSDEs, which allow for easier and more comprehensive analyses of CT radiation exposure. Our results indicate that implementation of SSDEs into national DRLs may be beneficial.


Assuntos
Doses de Radiação , Tomografia Computadorizada por Raios X/normas , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Estatura , Índice de Massa Corporal , Peso Corporal , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Valores de Referência , Estudos Retrospectivos , Tomografia Computadorizada por Raios X/métodos , Água , Adulto Jovem
8.
Acta Radiol ; 58(1): 70-76, 2017 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-26936899

RESUMO

BACKGROUND: Artifacts from metallic implants can hinder image interpretation in computed tomography (CT). Image quality can be improved using metal artifact reduction (MAR) techniques. PURPOSE: To evaluate the impact of a MAR algorithm on image quality of CT examinations in comparison to filtered back projection (FBP) in patients with hip prostheses. MATERIAL AND METHODS: Twenty-two patients with 25 hip prostheses who underwent clinical abdominopelvic CT on a 64-row CT were included in this retrospective study. Axial images were reconstructed with FBP and five increasing MAR levels (M30-34). Objective artifact strength (OAS) (SIart-SInorm) was assessed by region of interest (ROI) measurements in position of the strongest artifact (SIart) and in an osseous structure without artifact (SInorm) (in Hounsfield units [HU]). Two independent readers evaluated subjective image quality regarding metallic hardware, delineation of bone, adjacent muscle, and pelvic organs on a 5-point scale (1, non-diagnostic; 5, excellent image quality). Artifacts in the near field, far field, and newly induced artifacts due to the MAR technique were analyzed. RESULTS: OAS values were: M34: 243.8 ± 155.4 HU; M33: 294.3 ± 197.8 HU; M32: 340.5 ± 210.1 HU; M31: 393.6 ± 225.2 HU; M30: 446.8 ± 224.2 HU and FBP: 528.9 ± 227.7 HU. OAS values were significantly lower for M32-34 compared to FBP (P < 0.01). For overall subjective image quality, results were: FBP, 2.0 ± 0.2; M30, 2.3 ± 0.8; M31, 2.6 ± 0.5; M32, 3.0 ± 0.6; M33, 3.5 ± 0.6; and M34, 3.8 ± 0.4 (P < 0.001 for M30-M34 vs. FBP, respectively). Increasing MAR levels resulted in new artifacts in 17% of reconstructions. CONCLUSION: The investigated MAR algorithm led to a significant reduction of artifacts from metallic hip implants. The highest MAR level provided the least severe artifacts and the best overall image quality.


Assuntos
Artefatos , Articulação do Quadril/diagnóstico por imagem , Prótese de Quadril , Modelos Biológicos , Intensificação de Imagem Radiográfica/métodos , Tomografia Computadorizada por Raios X/métodos , Idoso , Algoritmos , Simulação por Computador , Feminino , Articulação do Quadril/cirurgia , Humanos , Masculino , Metais , Reprodutibilidade dos Testes , Estudos Retrospectivos , Sensibilidade e Especificidade , Resultado do Tratamento
9.
Forensic Sci Med Pathol ; 13(2): 145-150, 2017 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-28265799

RESUMO

The aim of this study was to evaluate the objective and subjective image quality of a novel computed tomography (CT) protocol with reduced radiation dose for body packing with 80 kVp and automated tube current modulation (ATCM) compared to a standard body packing CT protocol. 80 individuals who were examined between March 2012 and July 2015 in suspicion of ingested drug packets were retrospectively included in this study. Thirty-one CT examinations were performed using ATCM and a fixed tube voltage of 80 kVp (group A). Forty-nine CT examinations were performed using a standard protocol with a tube voltage of 120 kVp and a fixed tube current time product of 40 mAs (group B). Subjective and objective image quality and visibility of drug packets were assessed. Radiation exposure of both protocols was compared. Contrast-to-noise ratio (group A: 0.56 ± 0.36; group B: 1.13 ± 0.91) and Signal-to-noise ratio (group A: 3.69 ± 0.98; group B: 7.08 ± 2.67) were significantly lower for group A compared to group B (p < 0.001). Subjectively, image quality was decreased for group A compared to group B (2.5 ± 0.8 vs. 1.2 ± 0.4; p < 0.001). Attenuation of body packets was higher with the new protocol (group A: 362.2 ± 70.3 Hounsfield Units (HU); group B: 210.6 ± 60.2 HU; p = 0.005). Volumetric Computed Tomography Dose Index (CTDIvol) and Dose Length Product (DLP) were significantly lower in group A (CTDIvol 2.2 ± 0.9 mGy, DLP 105.7 ± 52.3 mGycm) as compared to group B (CTDIvol 2.7 ± 0.1 mGy, DLP 126.0 ± 9.7 mGycm, p = 0.002 and p = 0.01). The novel 80 kVp CT protocol with ATCM leads to a significant dose reduction compared to a standard CT body packing protocol. The novel protocol led to a diagnostic image quality and cocaine body packets were reliably detected due to the high attenuation.


Assuntos
Tráfico de Drogas , Doses de Radiação , Radiografia Abdominal , Tomografia Computadorizada por Raios X/métodos , Adulto , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Adulto Jovem
10.
Clin Exp Rheumatol ; 33(2): 209-15, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-25664925

RESUMO

OBJECTIVES: The objective of this study was to evaluate a simplified version of the Rheumatoid Arthritis Magnetic Resonance Imaging Score (RAMRIS) reduced to five joints of the hand (RAMRIS5). METHODS: 94 patients with rheumatoid arthritis (62 female; age 59±12 years, range 25-83 years; disease duration 60±90 months (median: 22 months, first quartile: 7 months, third quartile: 66 months) from the REMISSION PLUS study cohort who had complete files on C-reactive protein (CRP) levels and Disease Activity Score of 28 joints (DAS28) and complete MRI of the clinical dominant hand at baseline and after one year under anti-rheumatic therapy (follow-up time 12.5±1.1 months) in a dedicated extremity MRI scanner at 0.2T were included in this retrospective study. RESULTS: There was a strong correlation between RAMRIS5 and the RAMRIS sum-score for all patients (r=0.87, p<0.001) at baseline and follow-up (r=0.87, p<0.001). Among the subscores there was a significant correlation between RAMRIS5 and RAMRIS-MCP (baseline: r=0.66, p<0.001; follow-up: r=0.74, p<0.001) as well as between RAMRIS5 and RAMRIS-wrist (baseline: r=0.72, p<0.001, follow-up: r=0.69, p<0.001) at baseline and follow-up. CONCLUSIONS: RAMRIS5, a modified shorter RAMRIS score based on five joints of the hand is a viable tool for semi-quantitative assessment of joint damage in RA. This abbreviated score might reduce the time needed for image analysis in MRI-controlled studies in RA and might facilitate the use of MRI in studies on therapy response assessment in RA.


Assuntos
Artrite Reumatoide/diagnóstico , Articulação da Mão/patologia , Imageamento por Ressonância Magnética , Adulto , Idoso , Idoso de 80 Anos ou mais , Antirreumáticos/uso terapêutico , Artrite Reumatoide/tratamento farmacológico , Artrite Reumatoide/patologia , Feminino , Articulação da Mão/efeitos dos fármacos , Nível de Saúde , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Estudos Retrospectivos , Índice de Gravidade de Doença , Fatores de Tempo , Resultado do Tratamento
11.
Abdom Imaging ; 40(7): 2152-8, 2015 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-26048697

RESUMO

PURPOSE: The aim of this study was to evaluate the impact of a reduced tube potential (100 kVp) for non-enhanced abdominal low-dose CT on radiation dose and image quality (IQ) in the detection of body packing. METHODS: This retrospective study was approved by the local research ethics committee of our clinic. From March 2012 to July 2014, 99 subjects were referred to our institute with suspected body packing. 50 CT scans were performed using a 120 kVp protocol (group A), and 49 CTs were performed using a low-dose protocol with a tube voltage of 100 kVp (group B). Subjective and objective IQ were assessed. DLP and CTDIvol were analyzed. RESULTS: All examinations were of diagnostic IQ. Objective IQ was not significantly different between the 120 kVp and 100 kVp protocol. Mean density of solid and liquid body packets was 210 ± 60.2 HU at 120 kVp and 250.6 ± 29.7 HU at 100 kVp. Radiation dose was significantly lower in group B as compared to group A (p < 0.05). In group A, body packs were detected in 16 (32%) of the 50 patients. In group B, packets were observed in 15 (31%) of 49 patients. Laboratory analysis detected cocaine in all smuggled body packs. CONCLUSIONS: Low-tube voltage 100 kVp MDCT with automated tube current modulation in screening of illegal drugs leads to a diagnostic IQ and significant dose reduction compared to 120 kVp low-tube voltage protocols. Despite lower radiation dose, liquid and solid cocaine containers retain high attenuation and are easily detected.


Assuntos
Cocaína , Embalagem de Medicamentos/métodos , Corpos Estranhos/diagnóstico por imagem , Tomografia Computadorizada Multidetectores , Doses de Radiação , Radiografia Abdominal , Adulto , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Estudos Retrospectivos , Adulto Jovem
12.
Acta Radiol ; 55(1): 86-90, 2014 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-23884839

RESUMO

BACKGROUND: In the past decade the number of computed tomography (CT)-guided procedures performed by interventional radiologists have increased, leading to a significantly higher radiation exposure of the interventionalist's eye lens. Because of growing concern that there is a stochastic effect for the development of lens opacification, eye lens dose reduction for operators and patients should be of maximal interest. PURPOSE: To determine the interventionalist's equivalent eye lens dose during CT-guided interventions and to relate the results to the maximum of the recommended equivalent dose limit. MATERIAL AND METHODS: During 89 CT-guided interventions (e.g. biopsies, drainage procedures, etc.) measurements of eye lens' radiation doses were obtained from a dedicated dosimeter system for scattered radiation. The sensor of the personal dosimeter system was clipped onto the side of the lead glasses which was located nearest to the CT gantry. After the procedure, radiation dose (µSv), dose rate (µSv/min) and the total exposure time (s) were recorded. RESULTS: For all 89 interventions, the median total exposure lens dose was 3.3 µSv (range, 0.03-218.9 µSv) for a median exposure time of 26.2 s (range, 1.1-94.0 s). The median dose rate was 13.9 µSv/min (range, 1.1-335.5 µSv/min). CONCLUSION: Estimating 50-200 CT-guided interventions per year performed by one interventionalist, the median dose of the eye lens of the interventional radiologist does not exceed the maximum of the ICRP-recommended equivalent eye lens dose limit of 20 mSv per year.


Assuntos
Cristalino/efeitos da radiação , Exposição Ocupacional , Radiografia Intervencionista , Tomografia Computadorizada por Raios X , Humanos , Doses de Radiação , Radiometria/instrumentação
13.
J Cardiothorac Surg ; 19(1): 76, 2024 Feb 09.
Artigo em Inglês | MEDLINE | ID: mdl-38336743

RESUMO

BACKGROUND: Left ventricular assist devices (LVAD) are an established treatment for end-stage left ventricular heart failure. Parameters are needed to identify the most appropriate patients for LVADs. This study aimed to evaluate pectoral muscle mass and density as prognostic parameters. METHODS: This single-center study included all patients with LVAD implantation between January 2010 and October 2017 and a preoperative chest CT scan. Pectoral muscle mass was assessed using the Pectoralis Muscle Index (PMI, surface area indexed to height, cm2/m2) and pectoral muscle density by Hounsfield Units (HU). Overall mortality was analyzed with Kaplan-Meier survival analysis and 1-year and 3-year mortality with receiver operating characteristic (ROC) curves and Cox regression models. RESULTS: 57 patients (89.5% male, mean age 57.8 years) were included. 64.9% of patients had end-stage left ventricular failure due to ischemic heart disease and 35.1% due to dilated cardiomyopathy. 49.2% of patients had preoperative INTERMACS profile of 1 or 2 and 33.3% received mechanical circulatory support prior to LVAD implantation. Total mean PMI was 4.7 cm2/m2 (± 1.6), overall HU of the major pectoral muscle was 39.0 (± 14.9) and of the minor pectoral muscle 37.1 (± 16.6). Mean follow-up was 2.8 years (± 0.2). Mortality rates were 37.5% at 1 year and 48.0% at 3 years. Neither PMI nor HU were significantly associated with overall mortality at 1-year or 3-year. CONCLUSIONS: The results of our study do not confirm the association between higher pectoral muscle mass and better survival after LVAD implantation previously described in the literature.


Assuntos
Insuficiência Cardíaca , Coração Auxiliar , Humanos , Masculino , Pessoa de Meia-Idade , Feminino , Músculos Peitorais , Prognóstico , Resultado do Tratamento , Estudos Retrospectivos , Insuficiência Cardíaca/cirurgia
14.
Muscle Nerve ; 48(6): 889-96, 2013 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-23532987

RESUMO

INTRODUCTION: We investigated the utility of diffusion tensor imaging (DTI) for detecting neuropathic changes in proximal nerve segments in patients with peripheral neuropathy. METHODS: Twenty-one individuals with (n = 11) and without (n = 10) peripheral neuropathy underwent DTI of a defined sciatic nerve segment. Patients and controls were evaluated by clinical examination and nerve conduction studies at baseline and 6 months after the initial DTI scan. RESULTS: The mean fractional anisotropy (FA) value was significantly lower in sciatic nerves from patients with peripheral neuropathy as compared with controls. Sciatic nerve FA values correlated with clinical disability scores and electrophysiological parameters of axonal damage at baseline and 6 months after MRI scan. CONCLUSIONS: DTI-derived FA values are a sensitive measure to discriminate healthy from functionally impaired human sciatic nerve segments. DTI of proximal nerve segments may be useful for estimating the proximal axonal degeneration burden in patients with peripheral neuropathies.


Assuntos
Imagem de Tensor de Difusão , Doenças do Sistema Nervoso Periférico/diagnóstico , Doenças do Sistema Nervoso Periférico/fisiopatologia , Adulto , Idoso , Anisotropia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Condução Nervosa/fisiologia , Exame Neurológico , Curva ROC , Nervo Isquiático/patologia , Nervo Isquiático/fisiopatologia , Estatísticas não Paramétricas
15.
Neuroradiology ; 55(11): 1323-31, 2013 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-24026709

RESUMO

INTRODUCTION: Dynamic perfusion computed tomography (PCT) has been established as a diagnostic instrument for the detection of vasospasm after subarachnoid hemorrhage (SAH). The purpose of this study was to assess the prognostic impact of PCT parameters after SAH on the long-term outcome of patients. METHODS: Three hundred twelve patients were retrospectively interrogated with a questionnaire 23.06 ± 14.33 months after spontaneous subarachnoid hemorrhage. The modified Rankin scale (mRS) was determined, respectively. Scheduled PCT data sets from the first days after ictus were available for all patients. RESULTS: The maximum mean transit time over several examinations per hemisphere (MTTPEAK) values were significantly correlated (p ≤ 0.001, r = 0.422) with the clinical long-term outcome (mRS). Corresponding to our linear regression analysis, MTTPEAK is the second most important regressor (behind clinical severity of the initial hemorrhage) for the prediction of long-term mRS. An MTTPEAK threshold of 3.98 s (identified by receiver operating characteristic analysis, area under the curve = 0.75) predicted an unfavorable long-term outcome (mRS ≥ 2) with a sensitivity, specificity, positive predictive value, negative predictive value, and diagnostic accuracy of 67.3, 74.3, 84.5, 52.1, and 69.6 %, respectively. CONCLUSION: The presented data corroborate the relevance of PCT data for the clinical long-term outcome of SAH patients. By identification of patients who are at risk for a bad outcome and may need escalation of therapy, risk-benefit analysis is supported.


Assuntos
Imagem de Perfusão/métodos , Imagem de Perfusão/estatística & dados numéricos , Hemorragia Subaracnóidea/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Tomografia Computadorizada por Raios X/estatística & dados numéricos , Feminino , Alemanha , Humanos , Estudos Longitudinais , Masculino , Pessoa de Meia-Idade , Prevalência , Reprodutibilidade dos Testes , Estudos Retrospectivos , Medição de Risco , Sensibilidade e Especificidade , Hemorragia Subaracnóidea/terapia , Resultado do Tratamento
16.
Diagnostics (Basel) ; 12(7)2022 Jul 05.
Artigo em Inglês | MEDLINE | ID: mdl-35885532

RESUMO

Deep-learning (DL) noise reduction techniques in computed tomography (CT) are expected to reduce the image noise while maintaining the clinically relevant information in reduced dose acquisitions. This study aimed to assess the size, attenuation, and objective image quality of reno-ureteric stones denoised using DL-software in comparison to traditionally reconstructed low-dose abdominal CT-images and evaluated its clinical impact. In this institutional review-board-approved retrospective study, 45 patients with renal and/or ureteral stones were included. All patients had undergone abdominal CT between August 2019 and October 2019. CT-images were reconstructed using the following three methods: filtered back-projection, iterative reconstruction, and PixelShine (DL-software) with both sharp and soft kernels. Stone size, CT attenuation, and objective image quality (signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR)) were evaluated and compared using Bonferroni-corrected Friedman tests. Objective image quality was measured in six regions-of-interest. Stone size ranged between 4.4 × 3.1−4.4 × 3.2 mm (sharp kernel) and 5.1 × 3.8−5.6 × 4.2 mm (soft kernel). Mean attenuation ranged between 704−717 Hounsfield Units (HU) (soft kernel) and 915−1047 HU (sharp kernel). Differences in measured stone sizes were ≤1.3 mm. DL-processed images resulted in significantly higher CNR and SNR values (p < 0.001) by decreasing image noise significantly (p < 0.001). DL-software significantly improved objective image quality while maintaining both correct stone size and CT-attenuation values. Therefore, the clinical impact of stone assessment in denoised image data sets remains unchanged. Through the relevant noise suppression, the software additionally offers the potential to further reduce radiation exposure.

17.
Rofo ; 194(10): 1110-1118, 2022 10.
Artigo em Inglês | MEDLINE | ID: mdl-35545100

RESUMO

PURPOSE: To assess whether it is possible to reliably detect patients with strong suspicion of COVID-19 despite initially negative quantitative polymerase-chain-reaction (qPCR) tests by means of computed tomography (CT). MATERIALS AND METHODS: 437 patients with suspected COVID-19 but initially negative qPCR and subsequent chest CT between March 13 and November 30, 2020 were included in this retrospective study. CT findings were compared to results of successive qPCR tests (minimum of 3 qPCR tests if CT suggested infection) to determine the sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) of CT for diagnosing COVID-19. RESULTS: COVID-19 was diagnosed correctly with a sensitivity of 100 % [95 % confidence interval (CI): 65-100] and a specificity of 88 % [95 % CI: 84-90]. A PPV of 12 % [95 % CI: 6-22] and an NPV of 100 % [95 % CI: 99-100] were determined. CONCLUSION: CT is able to detect COVID-19 before qPCR in initially negative patients in this special study setting. Similar CT findings in COVID-19 and other atypical pneumonias can lead to high numbers of false-positive patients, reducing the specificity of CT. KEY POINTS: · Low-dose chest CT is able to diagnose COVID-19 in symptomatic patients even in cases of an initially negative quantitative PCR result and therefore is a fast support method to detect COVID-19, especially in early disease.. · Low-dose chest CT can reliably exclude COVID-19 in a pandemic setting.. · CT does not always ensure a reliable differentiation from other viral diseases.. CITATION FORMAT: · Valentin B, Steuwe A, Wienemann T, et al. CT Findings in Patients with COVID-19-Compatible Symptoms but Initially Negative qPCR Test. Fortschr Röntgenstr 2022; 194: 1110 - 1118.


Assuntos
COVID-19 , COVID-19/diagnóstico por imagem , Humanos , Estudos Retrospectivos , SARS-CoV-2 , Sensibilidade e Especificidade , Tomografia Computadorizada por Raios X/métodos
18.
Rofo ; 194(8): 862-872, 2022 08.
Artigo em Inglês | MEDLINE | ID: mdl-35211925

RESUMO

PURPOSE: Classifications were created to facilitate radiological evaluation of the novel coronavirus disease 2019 (COVID-19) on computed tomography (CT) images. The categorical CT assessment scheme (CO-RADS) categorizes lung parenchymal changes according to their likelihood of being caused by SARS-CoV-2 infection. This study investigates the diagnostic accuracy of diagnosing COVID-19 with CO-RADS compared to the Thoracic Imaging Section of the German Radiological Society (DRG) classification and Radiological Society of North America (RSNA) classification in an anonymized patient cohort. To mimic advanced disease stages, follow-up examinations were included as well. METHOD: This study includes all patients undergoing chest CT in the case of a suspected SARS-CoV-2 infection or an already confirmed infection between March 13 and November 30, 2020. During the study period, two regional lockdowns occurred due to high incidence values, increasing the pre-test probability of COVID-19. Anonymized CT images were reviewed retrospectively and in consensus by two radiologists applying CO-RADS, DRG, and RSNA classification. Afterwards, CT findings were compared to results of sequential real-time reverse transcriptase polymerase chain reaction (qPCR) test performed during hospitalization to determine statistical analysis for diagnosing COVID-19. RESULTS: 536 CT examinations were included. CO-RADS, DRG and RSNA achieved an NPV of 96 %/94 %/95 % (CO-RADS/DRG/RSNA), PPV of 83 %/80 %/88 %, sensitivity of 86 %/76 %/80 %, and specificity of 96 %/95 %/97 %. The disease prevalence was 20 %. CONCLUSION: All applied classifications can reliably exclude a SARS-CoV-2 infection even in an anonymous setting. Nevertheless, pre-test probability was high in our study setting and has a great influence on the classifications. Therefore, the applicability of the individual classifications will become apparent in the future with lower prevalence and incidence of COVID-19. KEY POINTS: · CO-RADS, DRG, and RSNA classifications help to reliably detect infected patients in an anonymized setting. · Pre-test probability has a great influence on the individual classifications. · Difficulties in an anonymized study setting are severe pulmonary changes and residuals.. CITATION FORMAT: · Valentin B, Steuwe A, Wienemann T et al. Applicability of CO-RADS in an Anonymized Cohort Including Early and Advanced Stages of COVID-19 in Comparison to the Recommendations of the German Radiological Society and Radiological Society of North America. Fortschr Röntgenstr 2022; 194: 862 - 872.


Assuntos
COVID-19 , COVID-19/diagnóstico por imagem , Controle de Doenças Transmissíveis , Humanos , América do Norte/epidemiologia , Estudos Retrospectivos , SARS-CoV-2
19.
J Cardiovasc Med (Hagerstown) ; 23(9): 608-614, 2022 09 01.
Artigo em Inglês | MEDLINE | ID: mdl-35994709

RESUMO

AIMS: The measurement of muscle mass reflects the physical components of frailty, which might affect postoperative outcomes in patients undergoing left ventricular assist device (LVAD) implantation. The aim of this study was to investigate the relationship between preoperative skeletal muscle evaluation and clinical outcomes in patients undergoing LVAD implantation. METHODS: From January 2010 to December 2017, a total of 63 patients were enrolled in this single-centre study. A retrospective analysis of preoperative abdominal computed tomography (CT) for psoas muscle index (PSMI) and Hounsfield-Units of the Psoas Muscle (PSHU) at the level of the mid-L4 vertebra was performed. RESULTS: Sixty-three patients (male; n = 49, 78%), with a mean age of 58.0 ±â€Š11.8 years, were treated with LVAD due to dilated (32%) or ischemic cardiomyopathy (68%). Among them, 43 patients (68.3%) were categorized in the Interagency Registry for Mechanically Assisted Circulatory Support profile I. The survival rate was 73.0% at 30 days and 44.4% at 1 year. Receiver-operating characteristic (ROC) curve analyses revealed that PSMI was a significant numeric predictor of 1-year mortality (P = 0.04). In contrast, PSHU displayed a significant predictive potential for pericardial effusion (P = 0.03) and respiratory insufficiency (P = 0.01). In addition, comparative ROC curve analysis revealed no significant difference in the predictive potential of PSMI and PSHU. CONCLUSION: Preoperative PSMI might be a predictor of 1-year mortality in patients undergoing LVAD implantation. In contrast, the PSHU seemed to potentially assume postoperative adverse events in this study. Thus, the evaluation of the preoperative psoas muscle using CT appears to be promising.


Assuntos
Insuficiência Cardíaca , Coração Auxiliar , Idoso , Coração Auxiliar/efeitos adversos , Humanos , Masculino , Pessoa de Meia-Idade , Músculos Psoas/diagnóstico por imagem , Sistema de Registros , Estudos Retrospectivos , Resultado do Tratamento
20.
J Cancer Res Clin Oncol ; 147(8): 2421-2433, 2021 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-33521862

RESUMO

INTRODUCTION: Proper management of the clinically involved neck in OSCC patients continues to be a matter of debate. Our aim was to analyze the accuracy of computerized tomography (CT) and ultrasound (US) in anticipating the exact location of lymph node (LN) metastases of OSCC patients across the AAO-HNS (American Academy of Otolaryngology-Head and Neck Surgery) levels ipsi- and contralaterally. Furthermore, we wanted to assess the suitability of therapeutic selective neck dissection (SND) in patients with one or two ipsilateral positive nodes upon clinical staging (cN1/cN2a and cN2b(2/x) patients). METHODS: We prospectively analyzed the LN status of patients with primary OSCC using CT and US from 2007 to 2013. LNs were individually assigned to a map containing the AAO-HNS levels; patients bearing a single or just two ipsilateral positive nodes (designated cN1/cN2a or cN2b(2/x) patients either by CT (CT group) or US alone (US group) or in a group combining findings of CT and US (CTUS group)) received an ipsi-ND (I-V) and a contra-ND (I-IV). 78% of the LNs were sent individually for routine histopathological examination; the remaining were dissected and analyzed per neck level. RESULTS: Upon the analysis of 1.670 LNs of 57 patients, the exact location of pathology proven LN metastases in cN1 patients was more precisely predicted by US compared to CT with confirmed findings only in levels IA, IB und IIA. Clearly decreasing the number of missed lesions, the findings in the CTUS group nearly kept the spatial reliability of the US group. The same analysis for patients with exactly two supposed ipsilateral lesions (cN2b(2/x)) yielded confirmed metastases from levels I to V for both methods individually and in combination and, therefore, render SND insufficient for these cases. CONCLUSION: Our findings stress the importance of conducting both, CT and US, in patients with primary OSCC. Only the combination of their findings warrants the application of therapeutic SND in patients with a single ipsilateral LN metastasis (cN1/cN2a patients) but not in patients with more than one lesion upon clinical staging (≥ cN2b).


Assuntos
Carcinoma de Células Escamosas , Linfonodos/diagnóstico por imagem , Neoplasias Bucais , Esvaziamento Cervical , Seleção de Pacientes , Adulto , Idoso , Carcinoma de Células Escamosas/diagnóstico , Carcinoma de Células Escamosas/patologia , Carcinoma de Células Escamosas/cirurgia , Feminino , Humanos , Linfonodos/patologia , Metástase Linfática , Masculino , Pessoa de Meia-Idade , Neoplasias Bucais/diagnóstico , Neoplasias Bucais/patologia , Neoplasias Bucais/cirurgia , Imagem Multimodal/métodos , Esvaziamento Cervical/métodos , Estadiamento de Neoplasias , Valor Preditivo dos Testes , Prognóstico , Reprodutibilidade dos Testes , Tomografia Computadorizada por Raios X , Ultrassonografia
SELEÇÃO DE REFERÊNCIAS